A down construction method is frequently used in these days to reduce popular discontent and to assure sufficient working space at early stage in downtown area. There are two main problems in the existing down construction method. One is a confliction between frame works and excavation works, and the other is a cold joint in retaining wall which is unavoidable due to a sequence of concrete placement and induces a water leakage. Therefore, a new method is needed to overcome these problems. The CWS (buried wale Continuous Wall System) method was developed by authors. By replacing RC perimeter beam with embedded steel wale, the steel frame works of substructure can be simplified and the water leakage can be prevented using continuous retaining wall. Consequently, the improved duality and reduction of construction period can be obtained from CWS method.
-
High strength concrete has been increasingly used in high rue building and it is very obvious re consider fire resistance performance of that. Unlike the normal strength concrete, high strength concrete in sudden elevating temperature at fire is susceptible to spalling with severe explosion and surface split, due to high density of concrete. In order to endure the spalling, inner space temperature of concrete should be control less than certain point. Therefore this study investigated the influence of covering materials on high strength concrete finishing spray-on materials of fiber composite spray mortar(FCSM). Both polypropylene(PP) and polyvinyl alcohol(PVA) fiber were used in this test. Test showed that concrete, covering 18mm mortar containing PVA fiber and confining metal lath 2.3mm thickness, decreased 50% of main bar ambient temperature. compared with control concrete. In addition, concrete covering 18mm mortar without fiber caused falling of covering materials and then it was exposed in elevating temperature. As a result, spatting of the concrete occurred same as control concrete. However, concrete covering spray-on mortar containing PVA or PP fiber resisted spatting occurrence.
-
The purpose of this study was to introduce the applied care of PC beam-column interior joint with splice type rebar. In this case, although the erection time of the introduced case was a little bit higher than that of general precast concrete method, this method was more effective than general precast concrete method in aspect of direct cost and the number of column joint. Therefore, this method could be adopted in the construction of the commercial and residential building in the future.
-
The test result of mat concrete applying both hydration heat difference and insulation curing method on new construction of Cheongju university educational building are summarized as following. Both fresh concrete and compressive strength properties were satisfied In aimed value. Setting time of concrete incorporating 15% of fly ash(FA) retarded 1.2 hour than control concrete. Temperature history of mali concrete indicated that the highest temperature of center was exhibited at
$126^{\circ}C$ after 51 hours while the highest temperature of upper section was$10.6^{\circ}C$ after 46 hours. Temperature Difference between center and surface was managed at less than$6^{\circ}C$ during whole curing period. In addition the temperature of upper section secured more than$3.3^{\circ}C$ while the temperature of outside was indicated at less than$-10^{\circ}C$ . Maturity by parts of construction secured more than$30^{\circ}C$ DD higher than outside at 3 days. The more number of times, applying insulation curing method by double bubble sheets, increased, the higher economic effect was secured. Overall it was clear that applying both double bubble sheets and hydration heat difference method on this new construction can resist hydration heat crack, early frost demage and strength decrease. It also significantly contributed quality improvement of cold weather concreting -
The quantity of Recycled concrete powder is increased, because it hal been ever so often crushing for production of a good quality recycled aggregates This Study is on the Development of Concrete-Product by Using Recycled Concrete Powder and alto for know performance of concrete-producted having low water contents and it is to know for all of performance of concrete-producted having low water contents The conclusions of this study are following. The use of replacement cement is not effective, because it has strengh of less than 10MPa But It is possible to develop high strength concrete-producted having 39MPa above compressive strength by using recycled concrete powder. Because strength enhancement effects by recycled concrete powder are responsible to optimum grading. The conclusions of this study are following. The use of replacement cement is not effective, because it has strengh of less than 10MPa. It is possible to develop high strength concrete-producted having 39MPa above compressive strength by using recycled concrete powder. Because strength enhancement effects by recycled concrete powder are responsible to optimum grading.
-
The study about the concrete to use recently a light weight aggregate, processed actively. And concrete pumping with a high pressure pump has been popularized, the mechanical development, such as high pressure pumps or pipes, is progressing rapidly. Concrete placing by pumping has the advantage of the reduction of the construction period with workability, easiness of work and the increase of placing, but the quality variation of concrete is caused by pumping is seldom considered, including the increase of the pipe length by high-rising and large-sizing, there by the loss of the unit quantity of water, with pumpability or workability deteriorated. In this research, we will compare and analyze before pumping and after pumping samples of ready-mixed light weight concrete. The result of study as follow. The case of a light weight concrete which the low slump is more decrement compared with high slump light weight concrete in after pumping samples. After pumping the water by pressure of a pump was absorbed to the aggregate inside, and it showed an increase of compression strength about
$5{\sim}20%$ . -
This study investigated influence of organic fiber type and contents on engineering properties of concrete. Test showed that increase of fiber contents decreased fluidity of fresh concrete and it was even worse in concrete adding cellulose fiber. It is decided that concrete containing more than proper level of fiber should be considered. In addition, concrete adding more fiber, nylon and cellulose, resulted in increase of air content but it was satisfied in aimed value. Bleeding capacity of concrete containing more fiber significantly declined and setting time of that was also slightly retarded. For the properties of strength, both compressive and tensile strength of fiber containing concrete were indicated at similar value to control concrete. However, it is clear that if those concrete containing fiber revised the value of increased air contents at fresh state, the strength value of that would be slightly increased.
-
In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.
-
This study investigated fundamental properties of lightweight foamed concrete using cement kiln dust (CKD) and both fly ash(FA) and stability agent. Test results showed that concrete incorporating more amounts of admixture decreased slump flow and it caused increase of superplasiticizer in order to secure the fluidity performance. In addition concrete adding stability agent showed stable flow state, resisting segregation of materials and decreasing bleeding capacity. Sinking depth of concrete incorporating 20% of CKD and adding 0.002% of stability agent was indicated at 0mm. For the properties of hardened concrete. compressive strength of concrete incorporating CKD declined due to a lower appearance density, compared with other specimens. The difference of that was not very significant and the value of ail specimen was higher than KS range. Moreover strength of concrete incorporating CKD was even higher at curing temperature
$5^{\circ}C$ . Tensile strength ratio of concrete incorporating CKD was indicated between 0.50 to 0.59, which is higher value than control concrete. Heat conductivity of concrete incorporating FA was under the KS range while concrete incorporating 20% of CKD was satisfied in KS. Concrete adding stability agent improved insulation performance due to the lower heat conductivity. In conclusion, it is possible that concrete incorporating 20% of CKD and adding 0.002% of stability agent can secure high quality of lightweight foamed concrete. -
Recently, more highly effective construction materials are needed for the reasonable and economical structure system is required as the construction structures become more multi storied, large-sized and diversified. That is to say, the highly qualified concrete, the molt universal construction material is positively promoted as a part of plan to establish the effective space according to the dead load of structures and diminish of segment profile and to build up the economic structures. In particular, it is tendency of that the study for high strength concrete increases and construction example of reinforced concrete (RC) using the high strength concrete partially increases. However, the high strength concrete has the problems such high brittleness and low ductility. Specially, for the high strength concrete, it has different strength from normal concrete as the internal temperature goes up steadily due to high heat of hydration by the quantities of highly level of cement, so the concrete which is mixed with various scible materials is used. This study conducted a basic experiment to conclude an adequate selection of materials and to calculate an optimal mixing proportion of those materials to produce High-strength concrete. And also we conducted an experiment to find out basic properties of this concrete such as slump-flow, strength.
-
In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.
-
Epoxy resin has less reaction shrinkage, has better water proofing and thermal resistance than other repairing materials, to it has been applied broadly to repair and finish buildings and infrastructures. Although the ambient temperature constructed is varied with the seasons and epoxy resin has to mix with appropriate hardener due to the non self-hardening, as the real construction of it, the ambient temperature is ignored and the blending ration of epoxy resin and hardener is fixed. Also, because of the hardening time is aimed to temperature condition and the tolerance of blending ratio, we investigated the variation of viscosity according to ambient temperatures and hardener ratios. As a results of study, we can select the economical blending ratio of the epoxy resin and hardener according to site situation.
-
Recently, trouble of sand supplying is occurred according to exhaustion of natural sand resources. Therefore various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. But because crushed sand have poor particle shape and plenty of makes micro particle, the quality of concrete using crushed sand deteriorated. Therefore, this study evaluated engineering property of concrete with replacement ratio of crushed sand and EEZ sand and applied evaluation result to fundamental data for quality control of concrete using crushed sand and EEZ sand. The result of this study have shown that quality of concrete using crushed sand and EEZ sand and The compressive strength of concrete up to 50, 70% EEZ sand replacement by crush sand, nearly equal to that of general sand.
-
Waste foundry sand of industrial waste which is happening by vast quantity according to fast development of industry has much the occurrence amount and processing method is depended on reclamation, and is using by fine aggregate for construction by recycling method among others. In this research Waste foundry sand powder into cement replace fare use possibility availability judge wish to Slump and air content decreased the replacement ratio increases by concrete special quality that do not harden according to experiment result, and unit capacity mass and bleeding increased the replacement ratio increases. Hardening concrete intensity special quality displayed strength improvement to replacement ratio 20%, and tendency that watertightness increases most in replacement ratio loft in watertight property appear. Considering the strength and watertight properties, the adequate usage of waste foundry sand powder is the 10% of replacement ratio.
-
In a traditional society, building materials were developed fulfilling the requirements of conveniences and functionalities such as safety, construction work, durability and economical efficiency. However, as the concern about environmental or users' health issues has been elevated recently, research and development about eco-friendly material are alto vigorously promoted further In addition, thanks to the steady growth of domestic industry, the amount of discharged industrial by-product is getting increasing. However, its recycling rate remain at low level as most industrial by-products are filled up in the land, which worsen the environmental pollution. Zeolite powder is cement admixture and is expected to have constraining effect of factors causing symptoms of inhabitants in a new house and alleviates the amount of discharged harmful elements emitted from hardened cement.
-
Problem of the environmental pollution and pollution by vast quantity occurrence of industrial waste by progress of industry is risen recently. Is real condition that waste foundry sand to be industrial waste that happen in casting industry of them has much the occurrence amount and the processing method is depending on most simplicity reclamation and so on. Therefore, by using waste foundry sand in the world by fine aggregate for mortar in recycling side of industrial waste necessity of development for new principal parts aggregate is risen along with rise of aggregate price by exhaustion phenomenon of natrual resources, wish to analyze physical and mechanical properties special quality and foretell practical use possibility availability.
-
This study investigated filling performance of concrete which can pass between reinforcing bars and be fully filled, and examined fundamental properties of concrete which is before or after hardened state, in response to maximum size of coarse aggregate. This study was also originally intended to find out one of the method that can improve concrete quality, using crushed coarse aggregate. Test showed that passing ratio of concrete decreased as aggregate site increased and as space between reinforcing bars decreased. In addition concrete using bigger size of coarse aggregate exhibited slightly higher compressive strength and showed lower length change ratio of drying shrinkage.
-
This study is intended for how to utilize the recycled fine aggregate which is produced by concrete wastes. It analyzes the quality of the fine aggregate which is reproduced through the acid treatment process, and comprehends the characteristics of mortar using the recycled fine aggregate to review whether it can be put to practical use for concrete. The conclusion of the study are as follows 1. The recycled fine aggregate through the acid treat shows the low rate of absorption and high density. 2. Compared to the mortar made from acid liquid precipitated recycled fine aggregate, using nature water precipitated one reduces the flow. 3. The compressive strength of mortar using recycled fine aggregate tends to be reduced according to the kind of precipitated water. Based on the above results, the recycled fine aggregate through the acid treatment process satisfies the quality standards of the first-grade recycled fine aggregate of KS F 2573 (recycled fine aggregate for concrete) but it is concluded that the recycled fine aggregate through the acid treatment process can not used as fine aggregate used concrete because it has destructive characteristics when the mortar is produced
-
Kim, Seong-Hwan;Pei, Chang-Chun;Song, Seung-Heon;Cha, Cheon-Soo;Han, Min-Cheol;Han, Cheon-Goo 85
This study investigated influence of fine aggregate types on fundamental properties of cement mortar. Test showed that concrete using lime stone crushed fine aggregate(L) exhibited the most favorable fluidity due to grain shape and particle distribution, and next was blending aggregate miting L and G, blending aggregate mixing L and N, granite crushed fine aggregate(G), natural fine aggregate(N) in an order. Concrete using N had the highest air content and L was the smallest value because of the effective filling performance by continuos particle distribution. Compressive, tensile and flexural strength of all concrete using L had the highest value due to the smallest value of air content. It is also found that concrete using L resulted in decrease of drying shrinkage length change ratio. -
To investigate the properties of high flowing and high strength concrete with crushed sand and fly ash for CFT structure, many batches were performed by a trial-error method. In the experiment W/B was set up three levels as 0.25, 0.30 and 0.35. Also the variables of the experiment were a substitution ratio of fly ash, a blend ratio of crushed sand and the ages of specimens(3, 7, 28 days). The results of this study are summarized as the follows; 1) The effect a substitution ratio of fly ash on the compressive strength was not consistent with age. For twenty-eight day compressive strength, the best result was come out when cement was substituted by 10% of fly ash. 2) The decrease of the water binder ratio, the increase of compressive strength and elastic modulus. Also the relationship is very similar to the case of a normal concrete
-
As the importance of recycled materials is being emphasized more in the Korean construction market, the production quality has been improved to a significantly high level. Compared to the high quality, however, there are used very limitedly. Among recycled construction materials, recycled aggregates produced through the retreatment of waste concrete are drawing attention because of lack of natural aggregate and heightened consciousness of resource saving and environmental protection and, as a consequence, they are close to natural aggregates in terms of production technology and quality. Despite the high quality and productivity, however, the utilization of recycled aggregates is very low.
-
This paper report the result of the investigation on the properties of drying shrinkage for alkali-activated slag mortar in different relative humidity Commonly we know that drying shrinkage means lost more moisture but the mechanism of drying shrinkage of alkali activated slag mortar is not entirely due to the quantity of weight loss of water from mortar. pore size distribution and the calcium silicate hydrate gel characteristics have a critical influence on the magnitude of drying shringkage to alkali activated slag mortar. For this investigation, Ca(OH)2, Na2SiO4 were as alkali activator with 5 dosages(6%, 9%, 12%, 15%, 20%) and curing condition were three different relative humidity(35%, 65%, 95%) at
$20{\pm}3^{\circ}C$ -
The revised legislation is introduced that the extension of the balcony area for the apartment houses is allowed. In the past the tenants had to install them illegally by themselves when they wanted to extend their balcony. We have reviewed the standard of the balcony's windows to be set up for them because the contractors can construct the exterior windows. At present, the detailed capacity standard for them is not established Of course some items of them are classified within five capacities among the KS standards. But the standard of the extensional balcony windows are not defined. Therefore this study is aimed at setting up the criteria of the noise, insulation and leak for the window system in expanding the balcony area and adopting it into window's works.
-
In this study, recently it is urgently required that recycle promotion of construction and demolition waste concrete because urban development is accelerated and redevelopment project is rapidly expanded, production quantity of construction and demolition waste concrete is being increased. On the other hand, it is urgently required that problem solution of demand and supply unbalance of fine aggregate because the sea sand is restricted by exhaustion of river sand and intensification of environment influence evaluation. Therefore, it tries to conform in time necessity, there is the objective of this study to provide the fundamental data about the re-application as the comparison and analysis the quality present condition for the recycled fine aggregate in the inside and outside of the country. At the same time it will be able to improve the quality of the recycled fine aggregate waste as investigating the physical nature and a quality present condition of the recycled fine aggregate from construction waste.
-
Recently, it is increased on the concern for the reuse of waste concrete because of the shortage of natural aggregate and the increase of waste concrete. And recycled coarse aggregate is used variously, but the existing wet method producted recycled fine aggregate has problem like the high price facilities, the long time progress of the work and the poor of recycled fine aggregate. The aim of this study is to investigate outline and performance evaluation of the drying specific gravity separation method to product high duality recycled fine aggregate. Finally, this study is shown investigate process flowing of drying separation type with gravity manufacture, producte system and function of detail devices. The performance of the method of drying specific gravity separation is certificated as the qualities of recycled fine aggregate satisfied the KS
-
Nowadays the using of concrete is generalized, and construction material is demanded to be lightweight according to increasing the height and capacity of buildings. Therefore, it needs to develop the products having the great quality and various performance. Extruding concrete panel made of cement, silica source, and fiber, and it is a good lightweight concrete material in durability and thermostable. The silica of important ingredient is natural material with hish SiO2 contents and difficult in supply because of conservation of environment. On the other hand, the stone powder sludge discharged about 20-30% at making process of crushed fine aggregate and it is wasted. The stone powder sludge is valuable instead of silica ole because the stone powder sludge includes water of about 20-60%, SiO2 of about 64% and it has fine particles. This experiment is on the properties of extruding concrete panel using the stone powder sludge use instead of silica. From this experiment, we find that it is possible to replace the silica as stone power sludge up to 50%,
-
Design-Build, one contractor is responsible for both the design and construction, has become more popular since the government framed the policy on how to activate the design-build projects in 1996. The reality is, however, there are many problems encounted on Contractor Selection Method for Public Design-Build Projects. The purpose of this paper is to improve the problems, no way to meet the goal(value) the owners expect from the design-build projects, for instance, not fully reflecting the characteristics of projects and owners intention, not systematical enough to judge if bidders could carry out the contract. This study will insist we introduce Best Value Procurement, which is being commonly used in some advanced countries recently, so that we would properly select the contractor suitable for Best Value concept which totally depends on the owners, types of work and specified conditions. Furthermore, by passing through the Two-Step Procedures following Pre-qualification in Best Value Procurement, we expect it lighten the bidders' burden for proposal and the owners' complicate bid administration.
-
Since the diversification, complication of the construction industry, construction conflicts have been increased these days. Expansion of scale of construction has brought conflict treatment cost increase. Thus, needs of the study on construction conflict risk factors and its management is getting important. But the existing studies about construction conflicts and risk factors that need to be cared to decrease construction cost are almost focused on analysis of number of conflict proposed. It means those studies can be helpful when want to know how many conflict have been instituted, however, they do not contain a close examination between types of conflict and cost of conflict treatment. The purpose of this study, therefore, is an extraction of conflict causes based on the conflict treatment cost and the choice of significant risk factors to be managed to prevent conflict and its treatment cost, which enables reducing the conflict treatment colt on control the risk factors.
-
Recently, Society increasingly need the hish-rise building because of urban population concentration. and The hish-rise building need new systematic work-planning method. but it didn't use the construction project's work plan and management. his paper investigated efficient work-planning method. and the work-planning method in using domestic High-rise building's structure work. A investigated result is TACT, DOC LOB etc. and domestic using method is 3day and 4day-Cycle among the Tact. This paper is to compare and analysis two method. a purpose of paper is to analyse application through the case of using the work-planning method. also To find efficient method.
-
The top-down construction method is an excavation and substructure construction method by excavating earth and building slabs from the ground level to the bottom of a building. The top-down method can be categorized into several types by its process and other technical details. Some of commonly used top-down methods in Korea today are S.O.G., N.S.T.D., and S.P.S. Among these, one method is chosen depending on construction field conditions, cost, construction time and so on. This study explores several factors that may affect the selection of a top-down method. This paper reports preliminary survey results with 54 top-down construction experts and comparison results of 5 top-down construction sites.
-
As underground construction is a large component of the cost of construction and a term of works in Top-Down construction, it is important to reduce the term of works in underground construction. The purpose of this study is to analyse buckling stress and load of prefounded columns as the process of excavation is changed, and propose a suitable process of excavation to increase the speed of works. When several floors are excavated, the valid buckling length of profounded column is increase and allowable buckling stress is decreased. The result shows that all columns are safe in buckling down to B3th story whether 2 stories or 3 stories are excavated straightly. However, several columns are not safe from B4th story when 2 or 3 stories are excavated straightly. With these results, a process can be designed that first B3 stories are excavated straightly, and then excavate B4th story putting concrete on B1st and B2nd story.
-
The building construction is an essential field to consider weather condition because construction works are performed in a site. From this reason, this study evaluated the effect of weather condition with work sections in building construction by Analytic Hierarchy Proces (AHP) method. The results of this study as follows : (1) The effect of weather condition with work sections is affected by rainfall in summer season, and by a low temperature in winter season (2) The effect of weather condition with work sections is 0.235 for mold work, 0.210 for concrete work, 0.181 for steel-frame work.
-
Photocatalyst reaction has limit of its usage because application range mostly centered on atmosphere purification area. Thus, it is true that an alternative plans are necessary to increase usage of
$TiO_2$ as photocatalyst material. (1) The result of flow felt according to$TiO_2$ replacement rate has shown that both of anatase type and rutile type over 12% deviated from desired flow,$110{\pm}5mm$ . Consequently, the range below 9% will be suitable when the anatase type$TiO_2$ if used for functional additives if workability is considered. (2) After compressive strength test, replacement rate 6-9% is estimated as suitable range if$TiO_2$ is used as compressive strength material. Rutile type and anatase type are suitable for in early-age strength and long-age strength respectively. (3) It was revealed that bending strength was dramatically decreased when replacement rate was increased. The main reason were the increase of$TiO_2$ doesn't influence hydration reaction and the decrease of bending strength. (4) The result from the water purification properties test using ion-chromatograhpy has shown that the condition with anatase type$TiO_2$ was normally better than rutile type on the same replacement rate. -
Deduction of compressive strength in concrete members is very important to decide stability of structures. In this study, we compare the compressive strength of concrete between nondestructive test done to the building which was to be demolished at residential reconstruction site and destructive test of core specimen from the site. The result is more reliable because ore can compare the measurement of nondestructive tell with the result from destructive test using drilled cores. Compressive strength of each material was calculated with the result of rebound number test. In addition, we performed ultrasonic test for another result of compressive strength. And we made a comparative study of compressive strength of concrete drawn from both nondestructive and destructive tests.
-
This study generally compared and investigated cement type and quality of China and Korea. Cement in Korea is divided into five such as ordinary, high early strength, moderate heat, low heat and sulfate resistance portland cement. However cement in China is divided into portland cement(
$P{\cdot}I,\;P{\cdot}II$ ) and ordinary portland cement($P{\cdot}O$ ) with admixture displacement ratio and it is again divided into 6 level and 7 level with 28 days compressive strength. In addition China classified cement into several standards, such as Mgo, SO3,, igloss, blame, setting time, stability, strength, alkali and sampling test. Therefore it should be careful to conclude so quickly without right understanding whether quality of China cement is bad or good. The better way to evaluate China cement is synthetically understanding a value engineering and consumer awareness. -
The purpose of the research is to assess the accuracy of steel bar detector among other nondestructive testing equipment. The result of previous research shows that the average errors of rebar detector are 14.7% for the cover depth, 2.3% for the rebar spacing, and 11% for the rebar diameter. But this experiment was performed at the laboratory and the mortar was used for covering the steel bars instead of concrete. In situ condition can be different from the laboratory's so the outcomes do not correspond with those of laboratory. This research was performed at the buildings to be reconstructed. Nondestructive and destructive testing can be performed side by side since the building if to be destroyed. Steel bar detector was operated on the beam and the column and concrete cover of those members was removed for the actual measurement of rebar depth, spacing, and diameter finally, presumed value can be directly compared with actual data.
-
In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chlorideion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of corrosion of reinforcing bar are inner chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Accordingly, it is considered that fundamental data on the performance evaluation and quality control standards of repair material and method could be presented through continuous exposure test in the future.
-
The purpose of this study is to investigate the cause of an error of prefounded column straightness and to measure the error during Top-Down construction. There are several causes of an error of prefounded column : (1) The columns are connected by welding or other methods. (2) concrete and aggregates are put in columns. (3) The columns are constructed during the construction. The error of column straightness is different for each column, and the tilting of columns is shown in one or two directions between floors. The additional loads caused by the error of straightness may give damage to buildings.
-
The accidents of oil leakage is increasing in the Underground Concrete structures for Oil Storege. In the result, the waterproofing in the underground structures is melt down and cannot fulfil its Performance. This study shows an experimental study in the effects of the oil leakage to on the performance of Waterproofing Materials. In order to investigate the actual condition and the problems, a comparative analyses were conducted considering the various types of leakage. Utilizing the obtained results at the basic data for test methods and the standard of quality, we intended to propose a strategy to develop an innovated waterproofing Materials and improve the clean environment of underground structures.
-
Recently, the balance of national properties of governmental offices and departments has been in deficit. Moreover, it has been also increasing rapidly. This study focuses on postal administration business which faces the financial crisis. The purpose of our study is to show devices for value improvement of pelt office. Research was based on a domestic post office which was decided to rebuild in Incheon Bupyeong. Research on domestic and foreign cases were carried out, superior cases for benchmarking was regulated so that these can be applied to the post offices to be built or to be remodeled.
-
This study deals with characterization and the application of magnetoelasticity as a device which measures existing steel stress. Available method of measuring existing stress needs break the concrete and cut the steel bar. But Proposed method doesn't need to cut the steel bar. A successful application of magnetoelasticity depends on the linearity of the relationship between the elastic and magnetic response due to loading. To investigate the correlation between two, steel bars are loaded in tension under uniaxial loading while the magnetic reading is recorded. Results showed linearity or partial-linearity of the elastic behavior of steel bars in relation to magnetic change. In the paper, the various factors affecting the measurements are also discussed.
-
The internal construction industry is not situation of cost reduction based on low wages anymore by the increase in wages as insufficient supply of stilled workers. Recently remodeling constructions that only need to change facilities as to stay the existing structures are on the increase. Now the method of piping facility used to remodeling construction needs stilled workers, large work space and a variety of tools. These complex construction process have a difficulty of high-quality and economical construction. In addition it have the hish incidence of warranty and a problem of cost increase as a commitment of manpower by warranty repair. In order to solve these problems it is necessary for appropriate new technology to the internal construction environment. Piping fittings by Insert & Coupling Joint is a method that unskilled workers can be easily constructed though one touch set up and it is convenient to maintain for repair work of piping facility. This technology show the effect of 3 percentages labor cost reduction as compared with piping fittings by press joint on apartment 500 households. Therefore this technology is supposed that attain a cost reduction though the technical and economical construction and a client satisfaction though the high-quality construction on the present construction market.