This study is to examine adhesion the characteristics of self adhesive asphalt to minimize of the construction periods and the environmental problems through the performance estimation of materials to reduce waterproof problem and the long durability maintenance of building structures. This study tested the estimation items of self rubberized adhesive asphalt to examine the sheet discovered the most important problem in the construction site and the connection stability in the sheet joint. Besides, this study examined the material characteristics such as tension property, tear property, temperature dependence, heat resistance, adhesion stability and so on. Test results of the separative items satisfied in the reference figure of connection stability and adhesion stability which could confirm adhesion performances and other items also satisfied in the reference.
-
Sound absorbing performance is affected by porosity and continuity of void, therefore it is important to maintain stabilization of foam and to analyze properties of void pore in hardened state. The purpose of this study is to analyze the sound absorption properties and void characteristic of foamed concrete according to dilution ratio of foaming agent. The results of this experiment were as follows. It is determined that an increase in total and continuous void ratio is achieved by increasing of dilution ratio, and a shorter absorbing time was exhibited at a higher continuous void ratio. When the average void size of foamed concrete was below 1.5mm, the tendency of sound absorption coefficient compared with general sound absorber was appeared similarly.
-
This paper investigated the temperature history of mass concrete mock up structure considering different heat generation by varying with mixture proportion. Setting time difference between high early strength mixture (E-P) and retarding mixture (R-F30) was 14.5hours. Incorporation of
$30\%$ of fly ash contributed to$10^{\circ}C$ of hydration heat reduction. In generally used C and D combination, bottom concrete shows earlier hydration, while E-J combination showed reverse tendency and thus, this method can reduce the crack occurrence. Therefore, heat generation difference method has beneficial effect on reducing crack induced by hydration heat resulting from heat generation difference between surface and center section. -
Generally, as corrosive protection processing of a steel structure, zinc galvanizing and heavy duty coating paint are applied. However, zinc galvanizing has the difficulty of restriction of a size, or on-site construction. Moreover, heavy duty coating paint has a problem with many administrative and maintenance expenses with short problem of adhesion, corrosion generating of a damage portion, and maintenance management cycle. In this study, a salt water spray test, CASS test, and the electrochemistry examination were carried out for the thermal metal spray method of construction for corrosive protection performance evaluation. Moreover, the corrosive protection life of a thermal metal spray method of construction was quantitatively calculated on the basis of this experiment. in consideration of LCC, the economical efficiency of a general corrosive protection method of construction and a thermal metal corrosive protection method of construction was compared. Consequently, although initial construction expense was estimated 16 to
$30\%$ high, as for a thermal metal spray method of construction, it turns out that the administrative and maintenance expenses for 100 years became cheap 9.3 to 13 or more times. -
This paper reported the temperature history of concrete placed at deck plate slab under cold climate condition by varying with surface insulating type. No curing sheet and simple insulation curing including non-woven fabric, double layer bubble sheet, the combination of double layer bubble sheet and non-woven fabric dropped temperature below zero within 24 hours, which caused frost damage at early age. On the other hand, the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam maintained minimum temperature above
$4^{\circ}C\;and\;8^{\circ}C$ , respectively. Based on core test results compressive strength of concrete with the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam was higher than those with other curing method due to good insulation effect. -
In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Daejeon. Horizontal placing lift is applied. According to test results,: slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. For temperature history, maximum temperature of center at top section shows
$25.6^{\circ}C$ , and at bottom section,$35.4^{\circ}C$ . According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete. -
This study shows the early quality improvement of concrete with calcium sulfa aluminate(CSA). For the properties of slump, plain concrete incorporating BS
$35\%$ and UP$15\%$ resulted in high fluidity compared with OPC without any admixture. As displacement ratio of CSA increased. the fluidity decreased. The fluidity also declined with setting time. Increase of incorporation ratio of CSA declined bleeding and accelerated setting time. Importantly, using more CSA helped to improve early compressive strength and decrease drying shrinkage. In term of water curing, drying shrinkage hardly ever occurred. -
It is recognised that a permeability waterproof agent have been extensively used for concrete, in these days. In present paper shows effective practical scheme of a permeability waterproof agent in construction market that is to develope durability of concrete structure as apply to job site through the examination physical and chemical property of a permeability waterproof agent. It is indentified that can be maintain waterproofing performance, moreover it makes satisfactory result of permeation resistance as applying siliceous waterproof agent.
-
Recently, Trouble of sand supply is occurred according to exhaustion of natural sand resources. therefore, various measures are proposed for solution of trouble of sand supply. also the government settled trouble of sand supply through application of EEZ sand and crushed sand. but because both EEZ sand and crushed sand are poor against general sand, they lead to lowering of quality of ready-mixed concrete. Therefore, this study evaluated physical properties of mortar using EEZ sand and crushed sand and applied evaluation result to fundamental data The result of this study have shown that quality of mortar using EEZ sand and crushed sand independently is poor against general mortar. but, mortar flow and compressive strength is increased in case of mixing 222 sand and crushed sand properly.
-
High Performance Concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However. spatting is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper focuses on the analysis of the temperature history and residual compressive strength with finishing material, in order to protect HPC from sudden-high-temperature, which is one of the main reason spatting occurs. Test results show that spalling occurs in all specimens. The most serious spalling took placed in HPC covering fire enduring spray-on material, whose covering thickness is 20mm but temperature history indicates that fire enduring spray effectively protected HPC from fire for more than 2hours. In addition, residual compressive strength ratio of HPC using fire enduring paint was more than
$90\%$ of original strength, thus minimizing spatting and indicating significant fire resistance performance. -
The aim of this study is to develop experimentally ultra high-strength concrete with compressive strength over 100MPa with current materials by important factors to influence the compressive strength of concrete. There are so many factors which influence the manufacturing of ultra high-strength concrete. But the experimental factors selected in this study are the sand aggregate ratio, the silica fume replacement ratio, the type of aggregate. the type of superplasticizer, the fiber mixing ratio. The results of this experimental study show that. it is possible to applicate in the field
-
This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of qualify control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.
-
It does not find for solution by limitation of technological mechanism of existent of leakage maintenance material. So, it is paid for huge expense because continuous repeat maintenance work is consisting. Furthermore, it is indicated by big problem in construction work that is constructed by field experience that thing by definite and systematic theory is not with proper performance test and analysis up to now. Therefore, wish to measure physical performance change by various environment condition maintenance of structure and performance construction work aspect in that apply to water leakage maintenance material using of acrylic resin system water expansion, leakage maintenance material in this research, and present suitable form of construction work under these environment. also, wish to ready diversified remedy by oversea market opening.
-
This is the experimental study on the strength development of the light weight concrete block according to the autoclaving time. The calcareous source used the cement, siliceous material used the bottom ash ground to fine particle, and the PP fiber used to increase toughness. The results of this experiment are as follows. According to the increase of autoclaving time and the fiber content, compressive and flexural strengths are increased. Despite of the changes of the autoclaving time, tobermorite was produced on each of the specimens. However, the phase of tobermorite was changed in accordance with the changes of autoclaving time.
-
Recently, there have been many studies about recycling cementitious powder from concrete waste(hereinafter referred to as waste powder), generated after recycle aggregate production. Previous studies showed that when the heating process of waste powder at
$700^{\circ}C,\;Ca(OH)_2$ in paste is dehydrated making possible the restoration of hydraulic properties. Recycled cement with hydraulic properties restored is thought to be re-hydrated through the mechanism of hydration, which is almost similar in Portland cement. This clearly suggests that the hydrate of recycled cement is alkali in type. Like in general concrete, if recycled cement is used as a structural material, resistance performance against carbonation or neutralization by$CaCO_3$ in air probably would be most influential to the life of steel-reinforced concrete structure. Thus the purpose of this study is to make an experimental review on chemical properties of recycled cement, manufactured with concrete waste as base material, and investigate the durability of concrete using recycled cement through evaluating the cement s performance of resistance to carbonation in accordance with its accelerating age. Based on its results, further, the study seeks to provide basic information about ways of utilizing recycled cement. -
This paper investigated the engineering properties of cement mortar mixed with more than 2 kinds of sand. For fresh mortar properties, unit volume weight is constant regardless of mixing content and type of sand. An increase in contents of river and crushed sand resulted in an increase in flow, whereas an increase in recycled sand contents reduced flow. Gap between maximum flow in N3C0R0 and minimum flow in N0C0R3 exhibited about
$12\%$ . Compressive strength at 28 days ranged from 32 to 36 MPa in order for crushed sand, river sand and recycled sand. Mortar with mixed sand along with river sand and crushed sand showed compressive strength comparable to crushed sand. An increase of fraction of recycled sand in mixed sand resulted in a decrease in compressive strength. For drying shrinkage, N0C0R3 had the largest drying shrinkage among various mixture type. The combination of large contents of recycled sand and small contents of river and crushed sand had a large amount of drying shrinkage. -
Recently, there have been many studies seeking towards the utilization of cementitious powder from concrete waste as recycle cement. However, most of the studies actually have been researches about the reuse of mortar or paste, not concrete waste. In fact, either mortar or paste is quite different from a real concrete waste in terms of age and mixture. Thus the purpose of this study is to examine basic physical properties of recycle cement, manufactured with cementitious powder from concrete waste, and analyze differences in chemical and hydraulic properties of the cement and its tested model. As a result of the chemicai analysis, recycle cement is composed mainly of CaO and SiO2, and that it is even lower in the content of CaO than Portland cement, which is also supported by previous studies. But, Differently from previous studies, plastic working at the temperature of 650 was found an optimal condition under which cementitious powder from concrete waste could restore its hydraulic properties.
-
Recently, Trouble of sand supply is occurred according to exhaustion of natural sand resources. therefore, various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. but crushed sand which have poor particle shape and plenty of makes micro particle the qualify of concrete deteriorated. Therefore, this study evaluated physical properties of mortar using crushed sand and applied evaluation result to fundamental data The result of this study have shown that quality of mortar using crushed sand independently is poor against general mortar. but, mortar flow and compressive strength is increased in case of using crushed sand according to mixing ratio properly.
-
The surface of concrete tiles is weak in moisture that it occurrenced efflorescence, but in the former study we found that it is possible to ensure moisture stability of concrete surface by autoclaving. So this study is to discuss the moisture stability and Physical Properties of high-strength glossy concrete according to time and temperature of autoclave curing. As the results, by increasing time and temperature of autoclave curing, compressive strength and surface hardness increased and glossiness decreased. In the case to 3 hour and
$180^{\circ}C$ of autoclave curing, there is not effloescences in mosture stability test. -
Due to increased demands for durable and high-performance concrete structures, the use of admixtures has become essential. In this paper, material properties, and durability of concrete mixed with natural inorganic minerals(R-1) are obtained from test results. Through the comparisons with OPC(Ordinary Portland Cement) concrete, the R-1 concrete shows improved compressive strength and durability.
-
The stone powder sludge occurred at aggregate production process is classified the specified waste, so it is disposed by appropriate method. But the problems of the shortage of the disposal-site, the environment pollution, and the increase of disposal cost can be occurred in handling process, therefore the stone powder sludge is required the development of recycling technique. The stone powder sludge includes SiO2 of about
$63\%$ . This characteristic is important at the production of hardened specimens under condition of hydro-thermal reaction. In this study, we investigated the strength properties of concrete used stone powder sludge as siliceous material. The test results under condition of hydro-thermal reaction shows the two main facts. The first, the stone powder sludge is affected to fluidity because the surface of the stone powder sludge has characteristics of flakily and angularity. The second, weight content of the stone powder sludge, is not effective factor to the properties of strength. -
This study investigates influence of particle properties of crushed sand on the duality of concrete. The test shows that an increase of fineness modulus(FM) resulted in high slump and air contents, while compressive strength decreased due to decreased adhesion with reduction of surface area. As grain shape become rounder, the slump of concrete increased, due to reduction of internal friction, and increased air contents. The reduction of adhesion by abrasion of surface declined compressive strength during the process of manufacturing crushed sand. Increase of powder contents decreased slump and it also decreased air contents due to the effect of filling air void. In addition. using powder contents increased compressive strength, but could not find any difference of bleeding and tensile strength with particle properties.
-
The Study on Compressive-Strength Property of the Aerated Concrete using Glass Fiber by Mixing RatioThe purpose of this study was to analyze the compression strength research by aerated concrete as mixing ratio This Study used foaming-agent and produced aerated concrete by pre-foam way that is used in construction site. An experiment changes unit cement amount, w/c and the glass fiber mixing rate and 'measured capacity change, unit capacity weight and compressive strength. The results obtained from experimental study are as following; Research to reduce unit capacity weight in condition more than unit cement amount 500kgf is considered should be gone side by side. The highest compressive strength result appeared in aerated concrete that cement amount 600kgf and w/c ratio
$45\%$ ,$50\%$ . compressive strength was increased maximum$34%$ when glass fiber$0.7\%$ addition cause by coherence enlargement to enlargement of cement paste and glass fiber addition per unit volume -
This study is as a part of the new disposal and recycling plans of heat-resource waste of Daegu dyeing, industrial center we tried to examine applicable possibility of crushed thing(waste aggregate) as aggregates for mortar and concrete. To examine applicable possibility of waste aggregate as a lightweight-aggregate for concrete and mortar, we carried this study by mainly property examination of concrete according to replacement ratio of waste aggregate. We carried slump, unit weight, compressive strength and bending strength test according to replacement ratio of waste aggregate. As the result of that, if we use waste aggregate, lightweight of concrete and mortar will be possible. Specially it shows a strength improvement effect of cement hardening according to using this so it is judged that applicable possibility as aggregate for concrete and mortar is very excellent.
-
Renovation of existing sports facilities or construction of temporary ones for international complex games requires a wide variety of hundreds of sub construction projects to be awarded at the same time but there are few precedents required regarding the study of tendering process required in such cases. As award of construction contracts to build sports facilities for various international complex games is a critical determinant of fate of international complex games in the initial phase, it is very critical that adequate construction tendering process bedetermined. This research is aimed to study tendering cases for renovation or construction of critical international sports facilities to enhance efficiency of facility construction and define most reasonable tendering approach to satisfy schedule constraints often associated with international complex games and contribute to improvement of international competitiveness of their host cities and propose a direction for further development. This study also provides inputs to subsequent sports events of comparable scale to minimize trial and error.
-
The ceramic metal resin paints for waterproof and anti corrosion is not long history in development of materials even many actual result. So far, no standard have been given to construction and maintenance method, Quality and property, it is real state that cannot afford to proper quality control in job site or production. This study has been test for the ceramic metal resin paints for water and anti corrosion, as the result, it have proper performance of job site and mechanical performance of compare to other existing. In particular, tensile strength indicates more high about
$14.1N/mm^2$ than epoxy resin paints, and in elongation per unit length is more high It is shows having better adhesive strength than epoxy resin paint for crack on the concrete structure. Moreover, The ceramic metal paint for water and corrosion proofing have to have main performance is watertightness and resistance for external impact, chloride ion permeation, drinkable water elution. -
It is necessary for prediction of recycled aggregate concrete(RAC) strength at the early stage that facilitate concrete form removal and scheduling for construction. However, to predict RAC strength is difficult because of being influenced by complicated many factors. Therefore, this research suggest optimized estimation method that can reflect many factors. One way is Case-Based Reasoning(CBR) that solved new problems by adapting solutions to similar problems solved in the past, which are solved in the case library. Other way is Artificial Neural Networks(ANN) that solved new problems by training using a set of data, which is representative of problem domain. This study is to propose comparing accuracy of the estimating the compressive strength of recycled aggregate concrete using Case-Based Reasoning(CBR) and Artificial Neural Networks(ANN).
-
Recently, to improve condition car park, using surface finishing material for variety color and property epoxy resin, urethane, cement mixed resin mortar or polymeric resin, and so on. However, it is frequent noise and wear out of tier and waterproofing materials, when the car slip or stop in car park, To minimize these cases, It is necessary that reduction of repair cost through performance long term durability of surface finishing material, improvement inside condition such as reduce dirty and car accident and ensurance the expected life of concrete slab in car park. Especially, we have not any tech for quality control, construction tech, production technology for car park surface materials, that's why park slab is not safety and suffer a loss. For this problems, this paper is to test surface finishing materials and as that result, suggest quality standard in the car park.
-
This study provides the method how to improve the productivity of a project using CM's constitutive methods. Construction industry in Korea was protected by the government and they have been grown with only their construction technology until today. It results Korean Construction is behind the advanced countries in terms of Engineering fields and construction management skills. This study compares the difference between the construction system of Korea and Europe and Asia. And then, it proposes the method how to compete with the other countries. which introduce the CM technique into the construction project in the beginning stage. Hopefully, this study is recognised as the basic strategy to improve the capability of Korean construction management.
-
In spite of a construction of many set building, the government's set building policies being almost indifferent to the maintenance management of them. Currently the personnel is not enough for maintenance management in set building. Therefore many set building does not become accomplished appropriately. On this paper, the set building policies and a questionnaire are analyzed. The result of questionnaire provides fundamental data of proper staff calculation.
-
Usually, processing whole project or a part of frame work delays due to acceleration, changing orders, management, characters of project. overtime, worker crowding, early occupation in the field of construction. Through a whole project, these factors cause decreasing construction labor-productivity which is the most dependent in business of construction. These kind of decreasing of construction labor-productivity cause many negative effects, just as extension of time, increasing cost in project of construction. Regardless of characters of construction or decreasing labor-productivity, extension of time is a incident which needs acceleration, also it cause a high possibility of claim and dispute. The productivity has just a broad meaning in business of construction. That's why it's difficult to apply in the field of construction. Especially, factors increasing or decreasing labor-productivity is defined by analysis of working as qualitative and outlined evaluation. However, study of the each factor decreasing construction labor-productivity analysis has not researched, because of difficulty of systematic measurement and management. The existed studies about management of productivity are just focused on estimation of productivity, not on evaluation of productivity. It was true that I couldn't examine clearly about the analysis of how much important per each the factor which have influence on labor-productivity because of the characteristic as qualitative that the labor productivity have On this study, i tried to get the factors decreasing of labor- productivity with gathering opinions of panels of expert's studies about the factors decreasing of labor-productivity on project of construction through Delphi method and i evaluated the result factors as quantitatively and subjectively about importance of factors decreasing construction labor-productivity Analysis, using AHP Method by Saaty. Also, using Delphi and AHP method, 1 suggest substantiated method qualitative factors are measured by quantitative criteria.
-
Was used at step space-time mainly after VE technique sponsors in domestic in the 1960s but have been expanded to design step recently. Possibility of value elevation or cost reduction must choose member that is effectively for active and effective application of VE technique. In this study, when enforce design VE examining for weight decision corrosion protection been using in weight grant composition estimation technique, target choice process wishes to suggest formality and method that can be achieved effectively. Main conclusion of this study sorts valuation items step by step for weight appropriation of valuation basis and give point on article of high position point after expert which employer is included estimates article by low rank step and this presented high position method that do union itembyitemandestablishesbyitemweight. Did these techniques for giving weights so that importance for weight appropriation developed estimation program, and data save of target estimation standard and target estimation standard is possible using straight sit.
-
The purpose of this paper is to develop a framework for strategic construction knowledge management. The variables of proposed framework includes knowledge types, strategic business functions, and engineering data types. The Proposed framework and knowledge action Plan for the construction company will contribute to develop knowledge management system related to engineering capabilities of strategic business functions
-
According to the trend of tail building, it is essential to improve productivity in tall building construction. However, the study on that is insufficient until now. Therefore, the purpose of this study is to propose a new work process of efficient concrete structural fame work to improve productivity in tall building construction. The results of being applied proposed work process are that the 5day cycle time of concrete structural frame work is cut by 0.5day and the quantity of rebar to be demanded in concrete structural frame work is reduced.
-
The fire damage of building wouid effect on the safety of structure. When the reinforced concrete structure is heated by high temperature due to the fire, the structural resisting-force will be decreased. In a way, it is a requirement to use high strength concrete for high rise building. Particularly, fire resistance properties of high-strength concrete is more important than normal strength concretes. The fire outbreak of a high strength concrete by sudden temperature rise is a main problem, and causes crack by thermal stress, loading to the deterioration of the durability. In this study, normal and high strength mortar were exposed to a high temperature environment. And than fundamental data for the character change of concrete heated highly were presented by measuring compressive strength of concrete with polypropylene and vinylon fiber, before and after heating. As the results, it is proven that high strength mortar with polypropylene and vinylon fiber for prevents deterioration of durability by fiber.
-
The tile construction methods for existing have been used materials within limit which adhesion by wet method in masonry wall and concrete structure. These existing adhesive tech can caused many problems in construction of large and reform tile, after that it can be happened loose scale, peel off, falling off tile by heat and vibration or impact. In according to, this study is to test tile for bond stability, adhesive property by impact, vibration. low property by heat and then, we have the results as below; (1) The tile adhesive stability can be effected as adhesive area between bond agent and tile, adhesive area can more wide and press enough to ensure property. (2) Existing adhesive strength and standard relative tile construction is limited to adjust performance tile on the concrete and masonry wall. In summary, It is necessary to establish standard of performance and test method to ensure tile adhesive salability in dry wall.
-
In apply roof waterproof system using of synthetic high polymer sheet for rooftop measure physical performance (tension
$\cdot$ tearing ability, temperature relativity, heating stretch performance, junction performance, wind resistance test) by various test environment condition waterproof test of structure and performance of construction work aspect, present suitable form of construction work under these environment. Also, wish to improve durability of concrete structure as that examine in priority about adhesion method and joint junction method with waterproof out surface, and present new direction about roof system application of waterproofing method for rooftop. -
Safe, economical and environment-friendly tunnel construction are required again along with social continuous development, the importance of waterproof work that is portion that actually all of user and builder can find that is embossed by tunnel construction's one of important construction. Also, ECB (Ethylen Copolymer Bitumen) sheet that is used in existing tunnel waterproofing method (ECB waterproofing method) being black because asphalt (Bitumen) is added, by purpose that make illumination of tunnel interior brightly and scar discovery eases in sheet with coating white film, but ECB that is used present according as ECB that asphalt is added does not satisfy high tensile strength of construction field, quality standard of extension. Also ECB denigrates color of black M/B that asphalt is excepted.
-
Unpreparedness of the maintenance regulations is regarded as the main reason for the short life span of the multi-owned commercial residential buildings. This study suggests that the followings should be prepared for the effective maintenance and life prolongation of the multi-owned commercial residential buildings : 1) Standard maintenance regulations for those buildings should be set up, 2) Building maintenance works should be performed by the specialists, like licensed building manager, mechanical and electrical engineers, etc., 3) Long-range repair expenses should be laid by on the monthly base according to the long-range repair plan, 4) Regulations concerning the defect repair should be provided properly.
-
This study started to confirm and prove for the applicability of the dry-process waterproofing system to cover the defects of the wet-process waterproofing system according to weather circumstance, foundation condition and maintenance, etc. This process has triple combined waterproofing system using asphalt sheet, metal sheet, engineering plastic film. It is not influenced by the concrete's crack as the foundation of the roof according to the movement of the building because the waterproofing system is designed for maintaining good quality by absorbing the stress of contraction and expansion that is occurred by the variation of temperature. Ali components used in this process can be recycled environmentally. The superiority of this process proved and reconfirmed through with the investigation of about 130 fields, around 30,000nf for two years.
-
The purpose of this study is to develop the evaluation method of repair performance for the repair method of reinforced concrete structures deteriorated due to combined deterioration, its results are summarized as the follows. After investigating and analyzing the experimental data of this study and existing research, it is proposed the evaluation method on the repair performance for the repair method of reinforced concrete structures using evaluation method of reinforcing corrosion by combined deterioration accelerated test.
-
Information Technology (IT) makes a great contribution towards improvement of productivity in construction industry. Because most of researches of construction industry's IT are focused on the whole field of the industry or development of information system, however, these have no regard for conditions in fields. Thus, this study proposes the requirements in order to improve the productivity and efficiency of field execution of construction industry. To achieve this aim, the surveys are conducted of the problems and conditions of IT application on site workers and managers. As a result, the followings are suggested: (1) user training should be exercised continuously, (2) infrastructure of IT constructed, (3) total management system of field execution developed, and (4) the development of IT system focused on fields. Therefore, this study provides meaningful proposal that can be set up basic direction toward IT investment and IT system development.
-
Recently, Deterioration of the concrete sewer concrete structures by biochemical corrosion has been issued and a development of the inhibition system of corrosion that has been demanded. The sulfuric acid may react with the hardened cement paste and originate expansive products which can induce swelling and breakless of concrete. Also, a sulphuric acid reacts with calcium hydroxide to from
$CaSO_4\;\cdot\;2H_2O$ . This reaction accounts for consumption of the calcium hydroxide present in hardened cement paste. In this study, To present from biochemical corrosion of the sewer repair mortar that was spread with liquefied antibiotic and then its experimental properties were experimentally investigated and to estimate the effect of absorbed condition of restorative mortar, the number of coating times and coating contents with antibiotic on the durability properties of restorative mortar spread with antibiotics. Also, testing items such as carbonation depth, choloride ion penetration depth and chemical resistance was tested to estimate the durability properties in third study. In results, the novellus bacillus inhabiting in sewer concrete structures was restrained by antibiotics developed in this study. And carbonation depth, choloride ion penetration depth and chemical resistance of restorative mortar spread with antibiotics was superior to that of plain mortar. -
This paper intended to evaluate the applicability of drying shrinkage reducing superplasticizer (DSRA) by investigating physical properties of concrete using DSRA, The application of flowing concrete method exhibited a less loss of slump and air content with time than those of conventional concrete and had small bleeding. Flowing concrete had larger compressive strength than base and conventional concrete by as much as
$3\~5\%$ . It also had less drying shrinkage by as much as$20\%$ compared with conventional concrete. This is due to the coupled effect of reduced water content and aqueous type expansive admixture. On the other hand, neutralization depth of flowing concrete showed greater than conventional concrete. -
Recently, remodeling has been a major field of the building construction that comes up for the alternatives of the reconstruction and the economical construction method. In the almost cases, the engineering capacity for the repair/rehabilitation of the remodeling should satisfy also the owner's various needs (eg, the minimum construction time, etc.) and the safety of the building. Also, the engineering and construction technique for remodeling should be applied to the contrary point of view of the general construction method. But, the many problem actually has arose from the wrongly applied construction method that is caused with the insufficient researches and development. Therefore, this study would suggest the necessities and the directions of developing the elementary engineering technique and the method that satisfy the owner's various needs for the remodeling and repair/rehabilitation of the multi-owned building as multiplex shop, with the successful construction cases.
-
In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing ,Fing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.