Proceedings of the Korean Institute of Building Construction Conference (한국건축시공학회:학술대회논문집)
The Korean Institute of Building Construction
- Semi Annual
Domain
- Construction/Transportation > Construction Engineering/Materials/Management
2008.05a
-
The purpose of this study is to ensure an amicable material quality control in the construction site through investigating a process which can impact the construction material quality. For it, a worker interview and questionnaire survey was conducted through a direct field visit. The visited construction sites are composed of 79% construction site and 21% engineering site. As the respondents of questionnaire survey, the quality control workers were 72% of total respondents. Next, the construction worker, handymen, field representatives and others formed 7%. The interview with the quality control staff was conducted with the items including the construction site quality control guide, incoming inspection and material management. Through this survey, the problems of quality control by progress phase were derived. It could be known that the management and measures by each phase were urgently required. It also was indicated that a selection of low-priced material caused by low price bidding could badly impact the construction and safety. Also, in relation to the opinions such as the insufficient quality control and heavy work-load, the improvements are required. For the effective quality control in the construction site, the material quality control procedures suitable for the phase of construction progress must be presented in the present quality control. Also, the standards for it need to be established.
-
As the land price in the downtown area increases, buildings are becoming bigger, deeper and higher. Consequently, the importance of underground construction has increased. Although construction engineers make every effort to complete underground construction without any problem, construction failures like landslides and the collapse of a retaining wall occur because of the uncertainty of the soil conditions as well as the unexpected risks of excavation work. In order to prevent potential excavation accidents, it is essential to understand the causes and impacts of such accidents. However, there are only a few examples of construction failures, which show the economic impact on accidents during excavation because of the sensibility of the information. This paper presents two cases of excavation accidents, which were investigated by construction insurance company. The compensation for the accidents paid by the insurance company was compared with the estimated costs calculated based on the estimation method for excavation accidents proposed by our previous study. The comparison results showed that the estimate calculated by our method was much less than the actual compensation because the estimate solely focused on the construction costs whereas the compensation included other external factors.
-
A study on the fire and smoke behavior on experiments and analysis through STAR-CD in using about behavior analysis of the smoke. Kerosene of 3L in using on the experimental garden of 30cm in diameter same applies to heat release rate(HRR), buoyant force by Plume can be calculated at a rate of 1m/s. The result of experiment in average of velocity were 0.29m/s, and interpreted result were 0.28m/s. Besides, it is proved by interpreted that behavior of smoke movement can be not observed in the experiment. After smoke is Plume increased, ceiling-jet in formation being descend in smoke layer will be more thick smoke layer, and then vertical wall is collapsed in formation of wall-jet being descend. It is defined that smoke layer is more thick through descending course in wall-jet and ceiling-jet.
-
The use of Precast Concrete (PC) stairways is increasing to replace existing Reinforced Concrete (RC) stairways for the faster construction and the better quality control. Among several already developed PC stairway construction methods, RC Core Sequential Construction Method by Using PC Stairways (COSEC) has advantages of 1) allowing core of a building to be built prior to PC stairways so that two different procedures will not interfere with each other, and 2) having a newly developed joint connection with the core so that the RC core and PC stairways can be easily put together. In this paper, cases of several construction sites with the PC stairways method are analyzed. The elements of the developed method are described for further application and improvement.
-
It is the aim of this study to investigate the fire resistance design Guidelines for high-strength concrete structure for example compressive strength more than 40Mpa. It is well know that explosive spalling due to fire attack of high strength concrete is related to concrete failure. so, the purpose of this study introduce the fire A Studty on the Fire Resistance Design Guidelines for High-Strength Concrete Structures of AIK for the response of explosive spalling of high strength concrete.
-
For the purpose of developing economical and time-efficient formwork for Top-down construction, a Non-Supporting Form System has been proposed. The system is consisted of two parts: a hanging part to support a steel frame and a section of concrete slab, and the other hanging part to lower the steel frame. In this paper, the proposed system is compared to two existing systems of Non Supporting Top-down Method and Bracket Supported R/C Downward Method. It is expected that this system can be used in Top-down construction with further development.
-
Kang, Seung-Ryong;Rhim, Hong-Chul;Kim, Seung-Weon;Kim, Dong-Gun;Song, Jee-Yun;Jeong, Mee-Ra;Lee, Hai-Chool 31
Construction of buildings downtown is increasing as much as ever with a strong demand. A Top-Down Method is suitable for its advantage in minimizing its disturbance to the neighborhood. In general, the Pre-founded Column, one of the most important aspects of the Top-Down Method, has been made with an H-Shape Steel Column. However, due to its structural and economical benefits, the usage of CFT(Concrete Filled Tube) columns in the place of Pre-founded Columns is increasing. To promote their applications, we analyze the merits of CFT columns by comparing them with I-Shape columns and propose further research. -
Qualitative enhancement of dwelling life has changing the recognition for the environment friendly wood which is being highlighted for its usage as an interior materials. This trend may prove the excellent performance of wood whose inherent characteristics has its comfortable, mild feeling of material, sound resistance and stabilities and the market of interior woods including floor, moulding and wooden panel as finishing interior materials is growing sustainably. However, since this materials is vulnerable to humidity and flame, waterproofing and flame retarding stability, an essential condition for interior materials, together with maintenance, are the main topics to be resolved. From the above-mentioned results, as a result of waterdrop contact angle, wood absorption volume and water content percentage test and the performance test of the processed materials after flame retardant, though there was some submerging time changes among types of woods for ensuring waterproofing performance improvement but as time passes, similar tendency was noticed to be formulated. As the submerging time is increased, so does the absorption volume and accordingly optimal level of range is judged to be drawn in order to ensure excellent performance, taking optimal economy into consideration. Therefore, it is considered that above-mentioned woods could be utilized for waterproof and flame retardant processed interior materials using uniform microwave and in order to put this technology into practical application, a research by way of diversified performance proving is required to be carried out.
-
In Top-Down construction for underground structures, the placement of slab as a horizontal supporting member against lateral earth pressure is an important process in determining construction time and cost. Usually, a reinforced concrete perimeter girder distributes concentrated lateral loads from earth retaining structures such as Cast-in-place (CIP) piles. By combining the function of the R/C perimeter girder and horizontal slabs, the Opened Slab Method is efficient for reducing construction time by elimination of time-consuming formwork for traditional perimeter girders. The structural performance of the method is also discussed in this paper.
-
This study analyzed the effect of increasing the number of times using aluminum form to the surface quality of concrete through small sized test, and the result was summarized as following. At the early stage, there was no remarkable change between aluminum and coated plywood form, and the surface quality of concrete both forms slightly declined corresponding with increasing the number of times using.As void on the surface corresponding to the number of times, the voids ranged 0.1~1mm were increased corresponding to increasing the number of times using forms, and the other range voids were also increased according to increasing the number of times using forms. It was confirmed that the surface of concrete was damaged gradually. For comparison with aluminum and coated plywood form though this experimental results, there might be no difference, if release agent was used properly.
-
Modern society is experiencing a high population density and a centralization of facilities. The clear trends in the construction field are aggrandizement, elevation and specialization of building structures. Such trends require improvements of skills in raising material performances, structuring, planning, designing, and increasing construction capacities. In order to procure high performance materials and construction techniques, a top-quality concrete should be used since it takes up a large part of the material. In recent years, active researches have been done on the ultra high strength concrete. Therefore, this experimental study is strength management to fixed quantity in the field of ultra-strong concrete.
-
This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and 15℃ even in case outside temperature drops -9℃ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than 4℃, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.
-
This study, having combined and displaced blast furnace slag("BS" hereinafter) known as admixture material that delays hydration reaction with coarse particle cement("CC" hereinafter) collected in particle classification method during ordinary portland cement("OPC" hereinafter), reviewed the hydration heat characteristics affecting the concrete. To reduce hydration heat, the study plain-mixed which used 100% OPC for W/B 50% level 1, displaced CC at level 3 of 25%, 50% and 75% for OPC, and by displacing BS with admixture material at level 5 of 0%, 20%, 40%, 60% and 80% for cement(OPC+CC), experimented totally 16 batches. As a result of experiment, in the case of flow, the more CC displacement rate increased, the more it tended to decrease, and the more BS displacement rate increased, the more it decreased. Also, as for simple adiabatic temperature rise by the CC and BS displacement rates, it decreased as displacement rate increased, and particularly in the case of displaced BS of 80%, It showed temperature reduction effect of about 63% companing with plain. Compressive strength decreased in proportion to displacement rate, however strength reduction increment was shown to decrease with age progress.
-
The study analyzed on fire resistance of high strength concrete followed by thickness of fireproof plaster board and change of adhesive method. In spalling characteristics after fire resistance test, all four-side covering concretes were left out of testing screens. Thus, serious spalling was happened by exposing their internal reinforcing rods. in partial testing screens, spalling was happened till the internal concrete of main reinforcing rod. Only, temperature history didn't have special differences among changes of adhesive method. However, thickness of fireproof plaster board is very important. Namely, mock member reinforcing 25mm general adhesive + Bending was 583℃ in the highest temperature of surface part and 479℃ in the highest temperature of the main reinforcing rod, which was relatively good temperature history.
-
In this study, we would like to study on the application of roof exposure waterproofing method of joint stability through shiplap rubberized asphalt color sheet to complement problem of fracture, exfoliation and water leakage by existing roof exposure sheet waterproofing material joint weakness. Accordingly, examined basis performance and stability for joint that shiplap rubberized asphalt color sheet through test of that tensile strength, bonding strength, water permeability after bonding, peel resistance after bonding, lengthen resistance after bonding and hang resistance after bonding. The results of this study, waterproofing method to using shiplap rubberized asphalt color sheet is judged to solved fracture, exfoliation and water leakage problems happened in joint by problem was joint of exposure sheet by minimizing gap of joint being integration by shiplap.
-
It has been reported that destruction test by core collection is the most reliable of the structural concrete strength in present building construction field. But it causes low efficiency by damage and cutting in structure due to the core collection. It also has some problems in repairing. Additionally in case of strength test with management specimen, different environment compared to the structure environment cause problems about estimation precise structure strength. Therefore, it is required to develop structure direct strength test that has test values and credibility above the ones obtained by core specimen collection strength test and seasonal specimen test to suggest a reasonable and practical management method of structural concrete.
-
The concrete used most in construction materials. There is an overcrowded iron dimensions use of the concrete at time of the other concrete theory on the reinforcing rod back which did congestion and compares it with this, and there are more few dimensions of the aggregate than concrete, and quantity of aggregate passage is superior in mortar than concrete. If a volume rate of the aggregate writes mortar than concrete against this, therefore, unit amount increases, and quantity of paste increases and quantity of dry shrinkage than increase concrete. However, I let I regulate lay priest distribution of the aggregate, and the results rates increase and reduce unit amount and decrease quantity of dry shrinkage, and separation resistance and the gap passage characteristics are judged because it can be it in a substitute document of very superior concrete. I came to carry out the study that I watched to let I was useful a little more and do the improvement repair of a become building wall body, a basement pillar and repair reinforcement of the assistant in the reinforcing rod back, the old age when I made congestion here. I regulated lay priest distribution of the aggregate in the study and regulated substitution rate of the aggregate (40%, 50%, 60%) and divided W/C 30%, 40% standards and produced mortar and I compared quantity of air by this, slump, compression robbery and showed it this time.
-
The study examined fire resistance of concrete followed by change of mixed rate in PP and NY composite fiber and the results were as follows. In the event of fluidity in concrete not set, plane satisfied 600±100, its target slump flow, and fluidity was reduced as organic fiber's mixed rate was increased. Air amount satisfied 3.0±1.0, its target air amount, and didn't have distinct differences in reduction and increase according to organic fiber's kind and change of its mixed rate. However, it had a tendency that fluidity was reduced as the mixed rate was increased. In characteristics of hardening concrete, the 28th day compressive strength followed by organic fiber's kind and change of its mixed rate didn't have a lot of differences and satisfied high strength scope as about 70MPa. In spalling characteristics after fire resistance test, spalling was happened in non-mixture, plane combination, and P1N0. In other combinations, spalling resistance was happened. The relic compressive strength rate was 56%, the best condition, in P3N1(PP0.03%, NY0.01% compositeness) mixing PP fiber with NY fiber at once.
-
The study analyzed on each kind of basic characteristics in mortar to prove an effect of pre-mix cement, ultra high strength binder. The results were as follows. in characteristics of not set mortar, fluidity time was the quickest at the time of using POBSA and was more delayed at the time of using Fly Ash than at the time of using Blast Furnace Slag as a binder. Mortar ring flow and flow con flow got smaller as fluidity time got longer, on the contrary to fluidity time. Unit capacity mass was smaller at the time of using Fly Ash than at the time of using Blast Furnace Slag. According to pre-mix, it was difficult to discover a regular tendency. In characteristics of hardening mortar, the 28th day compressive strength was better than thing mixed after measuring separately in pre-mix. According to a binder's kind, Silica Fume B, C was better than Silica Fume A.
-
This study investigates the properties of the flow, air content, strength, hydration heat, and the autogenous shrinkage, and the results are summarized as following. As a properties of fresh concrete, the flow increased and the air content decreased as the replacement ratio of BS increased. The time of set delayed as the replacement ratio of BS increased by latent hydraulicity. The compressive strength of hardening concrete was smaller than OPC as the replacement ratio of BS increased at young concrete, however it was more than equal after 28th day and from then on. The rising temperature ratio which occurs by simplicity insulation decreased as the replacement ratio of BS increased, but it increased by latent hydraulicity reaction at the latter half. The length ratio of autogenous shrinkage of OPC was 319×10-6, however it was shorter when the replacement ratio was 40% as showing 290×10-6.
-
This study was to execute the experiment for analyzing the quality characteristics of mortar by type of recycled sand by using the recycled sand produced by the manufacturing system by wet gravity separation in order to develop the removal device of impurities for the production of high-quality recycled sand. As a result, this study has sown that the mortar using the high-quality recycled sand through the manufacturing system by wet gravity separation in the fluidity property, strength property, and shrinkage property largely, compared with the mortar using low-quality recycled sand that not passed the device of sand flux. There was a tendency similar to the plane mortar. In conclusion, it was considered as various quality performances of the recycled sand were improved through the production stage of prototype.
-
The productivity is the one of the primary elements to evaluate the new systems performance for building construction along with the economic efficiency, the safety, and the quality improvement. At present the on-site construction automation systems(we will call it as Construction Factory or CF hereafter) is under the development by research group for construction automation of high-rise building. The system includes many sub-systems such as a robotic crane, a construction factory, bolting robots, a building material management system using RFID and so on. In this study we discuss and propose the method to evaluate for these hybrid on-site automation system fundamentally. In future we devise a framework of evaluation modules for the on-site building automation system on the basis of this discuss.
-
This study investigates practical application of high early strength type concrete using fine particle classifying cement, and the results are summarized as following. The replacement use of FC 30% did not great influence on concrete mix, therefore mixing without additional SP and AE was available using equal mix with OPC. The ratio of increasing temperature by heat of hydration was similar with OPC, and the compressive strength was over then 5MPa at -28℃ outside temperature on 2nd day. Therefore, it is considering that the first purpose, the effect of shortening terms of work by early demolding, will be available. The rebound rate of type "P" schumidt hammer was relative with compressive strength, and the rebound rate for verifying 5MPa of compressive strength was estimated about 55 considering rate of safety. Therefore, assuming demolding date is available efficiently.
-
The construction industry highly depends on each specialized manager which is essential to successful project. However, a new employee, who has just graduated from architectural engineering college, is requested additional education for 1~2 years such as On-the-Job-Training (O.J.T) to perform his/her professional job in construction site. It is wasteful for both construction company and the employee in terms of time and cost. The purpose of this paper is to investigate the required abilities and analyze the gap of demanded abilities between field managers and students. To collect data for analysis, questionnaire which uses Likert Scale has been performed to both parts. As a result, the analysis show that the graduate's abilities related to field experience get especially low degrees in compare with non-field experience factors. These results will contribute architectural engineering education in college to make more realized.
-
The successful project management is based on definition of project goals in construction industry. The WBS(Work Breakdown Structure) is one of the major factors which defines works related to project goals. The necessity of the WBS for owners in multi complex projects which would help them to understand the whole project is rising because the multi-complex project in the construction industry has increasing recently. Therefore, this study suggests directions to establish the WBS for owners through investigating a concept of the multi-complex project first and analyzing types of project, domestic and foreign WBS, and case studies.
-
Productivity is an important factor of the construction's success and growth. However, compared to the other industries, the study of productivity in the construction industry is still insufficient. Even though the Cast-in-Place piles work is also important in construction process, the research on the productivity is not enough. So, it is necessary for the systematic research on the productivity of Cast-In-Place Piles Work. Therefore, the purpose of the study is to classify lower productivity's cause and find a way to improve these situations. This study will give the checklist for the further study of factoring and improvement of the Cast-in-Place piles work productivity.
-
Baek, Dae-Hyun;Joung, Woung-Sun;Park, In-Beom;Song, Seung-Heon;Baek, Byung-Hoon;Han, Min-Cheol 141
In this paper, non working day for the construction project in Cheongju region considering weather condition for 30 years from 1971 to 2000 and 10 years from 1991 to 2000 as statistical periods was estimated. In Cheongju region, there was no remarkable difference between them because non working day for outside and half outside work was 157days and for interior work 144days at statistics for 30 years., and utside and half outside work was 159days and for interior work 142days at statistics for 10 years.. However, non working day due to high temperature is slightly increased, and non working day due to cold weather is slightly decreased in the case that the recent statistical data was used caused by global warming. Non working day due to rainfall was 23 days at statistics for 30 years, and it was 28 days at statistics for 10 years. -
Construction project is completed through several stages and problems of each stage affect directly not only now but also next. Defect of 2D drawings influence in construction phase, and it make many loss on project. Nowadays we practically use real Mock-up test in construction sites to solve the problems. But it also has many problems which are waste much money and time. Therefore, this study tries to analyze effect that is occurred by appling BIM Mock-up simulation instead of real Mock-up execution. These analysis is conducted by comparing two construction building site. These have same shape but one is made for BIM Mock-up, and another is real Mock-up. Comparison points of view are cost, time and operator's satisfaction. It is expect that BIM Mock-up is more effective at low cost and on shorter time. But our analysis show that each are conducted different part of function. So new Mock-up type is required. Hybrid Mock-up is combine real mock-up with BIM simulation and it can minimize risk of project.
-
The construction market has gradually become complexity, variety and specialization, and then owner's requirements about quality has become various. In order to solve the problem such as stated above, advanced constructions in United Kingdom, Japan and United States have introduced warranty contract which is warranted to quality and performance for need of owner in determined term to ensure the quality of construction since 1960s. However, the interior of a country encounter another problem result from defects liability what indefiniteness of defects standard, excess responsibility period, social recognition of be identical fraudulent work and defects, and contract with ascendancy of owners. etc, so builders concerned more excess defects liability than the quality of construction. The purpose of this study is to analysis of warranty contract in order to solve the problem such as stated above.
-
A Study on the composition of PFV(project financing vehicle) used in large-scale development projectThe trend of Development Projects has been changing through a few recent years. Small-scale development projects in the past were usually for building residences or officetel in a big cities. making lots of profits. These projects made not only lots of profits but also unbalance between the urban centers and the suburbs. So government made some regulations to prevent the things from being worse anymore, planned to develop the country in balance and began to lead large-scale development project such as Inno city and Newtown. At first, in this study, the phases and the characteristics of development project's change will be looked around. And then, after overview about PFV(project financing vehicle) used a lot in large-scale development projects will be seen, the better ways to use PFV in large-scale development projects are going to be proposed by considering the problems in PFV's conformation.
-
In other side the recent construction industry is a skyscraper, a large scale and a sophistication, a construct site have many problems that an aging of worker and shortage of work force. The purpose of this study was to develop the location of tower crane and the simulation technology of tover crane. The automation of tower carne is a important component in skyscrapers. Specially, this study suggested that it was to develop the exact location system through GPS(Global Positioning System) better than former times.
-
There are researches are in progress on ensuring the safety of the high impact concrete in cases of fire which is a current rising social problem and this research institute also developed PFB technology, the explosion preventing technology. PFB technology is to apply POSCO E&C Fire Board, a fireproof board, with an adhesive agent on the construction site, and this technology passed 3-hour fireproof test and this technology was proven from a previous research that the temperature of main root is maintained under 200 ℃. Therefore, tests on basic contents to be examined before the actual construction in this research by with a wooden prototype of a full scale to apply PFB technology to actual construction sites and tests are being done on the workability of fireproof board, the adhesive power, the resistance against imprint of wooden nail, the heat conductivity and etc. As the results of those tests, PFB technology was proven to have an excellent workability at a construction site and to be easy for processing and also this technology was proven to have a great the resisting power against imprint of wooden nail, so this research has confirmed that PFB technology has no problem to be applied on a construction site.
-
Recently, amount of High-Rise Mixed-use Building is Increasing based on Preference of comfortable residence and good view. Government policies were turned to prefer about High-Rise Mixed-use Building because of decreased real estate Condition. But these changes have revealed that it has many maintenance problems for example- efficiency, economic, environmental problems. This paper suggests that the Database System based on various alternatives and real case. And it will be a tool in the scientific decision and value analysis from the facility management to make optimized decision.
-
Carbonation is measured as Phenolphthalein Solution, it is possible to confirm the scope of alkali through acid and basic reaction. Then, Concrete Basic Reaction is decided according to alkali concentration depending on Potassium Hydroxide Now that Carbonation is gradually produced toward inner side from outer side, with time going by, it doesnt work, to some adequate depth, in as fast time as compulsory facilitating test. Thus, this research thesis made a comparative analysis on concrete phenomenal discoloration borderline following Phenolphthalein Solution, as part of a bid to measure Carbonation. Also, the thesis measured Concrete Alkali Concentration. The result showed that concrete coloring is classified into red and scarlet according to alkali concentration, and into borderline breakpoint of the speckle of scarlet and carbonation reaction. The higher chroma becomes with concrete decolorizing, the higher alkali concentration becomes.
-
This study focuses on applying performance-based design to construction standard in building construction. First, it realizes situation and issues of standard specification in building construction, deduces the need factors for establishing performance-based construction standard, and then, it proposes the application of performance standard. The required stages for deducing performance-based construction standard consist of dividing building parts, deducing required functions, performance items and performance requirement and deciding a method of performance evaluation. Through these stages, performance-based design process is deduced.
-
Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) that is an excellent internal force and deformation capacity because material and method are required to be diversification and High-Performance according to increase the super-high structure. And it is proposed to use high-strength Concrete Filled steel Tube Column. But it is difficult quantitative evaluation about fire-resist performance of CFT because steel tube bind concrete. Also, the case of high strength CFT is feared that spalling occur inside. Therefore, this study made CFT specimen that determine the factor(which is strength of concrete) and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, it tried to analyze internal temperature through nonlinear transient heat flow analysis.
-
The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites(ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 3 HSC specimens are being exposed to fire, in order to examine the influence of various parameters(such as depth of layer=20, 30, 40mm; construction method=lining type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion(3hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.
-
The results of the status analysis for the safety accident are as followings which is prepared for the purpose of collecting a basic data for securing residential safety in houses and buildings. (1) As for the safety accidents of the aged in houses, 66% of all safety accidents were slipping and falling and there was no serious difference in frequencies of accidents according to the places. (2) As for the safety accidents of children in houses, 74% of all safety accidents concentrated on bedrooms and living rooms and the majority types of accidents related to architectural matters were bumping, slipping, and falling.(3) There was striking difference in the frequency of safety accidents in houses between aged and children, according to places and types of accidents.
-
Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.