• 제목/요약/키워드: lateral current

검색결과 557건 처리시간 0.039초

A simple Model for Separation of the Tsushima Current Stream Core by the Tsushima Island: a small viscosity limit

  • Seung, Young-Ho
    • Journal of the korean society of oceanography
    • /
    • 제38권2호
    • /
    • pp.45-51
    • /
    • 2003
  • Recent observations reveal that the Tsushima Current has a double-cored structure downstream of the Tsushima Island. To explain this, a simple analytical model is proposed based on the assumption of small lateral eddy viscosity. This model suggests that an otherwise uniform current becomes to have a stream core immediately after it enters a channel due to the action of lateral friction. The core is initially broad but becomes sharper downstream. The speed at which the core develops depends on the intensity of lateral eddy viscosity. Likewise, a single-cored stream changes rapidly to a double-cored stream when it passes through an island located in the center of the channel. When the stream leaves the island behind, the reverse process from the double-to single-cored structures takes place. In this case, however, the double-cored structure is retained for a significant distance from the island. Overall, this model suggests that the double-cored structure of the Tsushima Current observed downstream of the Tsushima Island Is created by the lateral friction exerted by the Tsushima Island.

BCD Platform과의 집적화에 적합한 고성능 Lateral Super Barrier Rectifier의 연구 (A Study on High Performance Lateral Super Barrier Rectifier for Integration in BCD (Bipolar CMOS DMOS) Platform)

  • 김덕수;이희덕
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.371-374
    • /
    • 2015
  • This paper suggests a high performance lateral super barrier rectifier (Lateral SBR) device which has the advantages of both Schottky diode and pn junction, that is, low forward voltage and low leakage current, respectively. Advantage of the proposed lateral SBR is that it can be easily implemented and integrated in current BCD platform. As a result of simulation using TCAD, BVdss = 48 V, $V_F=0.38V$ @ $I_F=35mA$, T_j = $150^{\circ}C$ were obtained with very low leakage current characteristic of 3.25 uA.

A Review on Lateral Flow Test Strip for Food Safety

  • Kim, Giyoung;Lim, Jongguk;Mo, Changyeun
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.277-283
    • /
    • 2015
  • Background: Foodborne disease outbreaks from various food sources are a major health concern worldwide. Current methods for detection of foodborne pathogens are both expensive and time-consuming. Purpose: This review aims to present the current information available on the use of lateral flow test strips to detect pathogens in food products to enhance food safety. Results: Frequent foodborne disease outbreaks from various food sources have increased the need for rapid and easy methods for routine analysis of foodborne pathogens. Present detection methods for foodborne pathogens require expensive instruments, experts, and long time for sample analysis. Lateral flow test strips have drawn attention in recent years because of their ability to detect analytes quickly and easily. This review focuses on the principle of the lateral flow test, the various formats of lateral flow test strips, recognition elements, labeling tags, and reading instruments. In addition, this review also discusses the future prospects for the lateral flow test strips.

실선 예인실험을 통한 여객선형의 유압횡력계수 고찰 (The Lateral Current Force Coefficient in the Real Ship Towing Test)

  • 정창현;남택근
    • 해양환경안전학회지
    • /
    • 제22권5호
    • /
    • pp.373-379
    • /
    • 2016
  • 접이안이나 사고선박 예인 등 선체를 횡방향으로 이동시 유압력은 수심/흘수비(h/d)에 따라 상당히 달라진다. 하지만 h/d에 따른 유압횡력계수는 선종에 따라 다소 차이가 나는 것으로 알려져 있지만 OCIMF에서 제시하고 있는 유조선 이외의 선종에 대해서는 관련 연구가 많지 않다. 따라서 본 연구에서는 93 m 여객선형 선박에 대한 횡이동 실선실험을 통하여 h/d에 따른 유압력횡력계수를 이론식에 적용하여 상호 비교 평가하였다. 그 결과 대상선박은 h/d=1.6에서는 유압횡력계수를 1.9로 사용할 경우 총저항이 14.0톤으로 실측된 13.8톤의 장력과 거의 유사하였고, h/d=3.0에서는 유압횡력계수를 1.3으로 가정할 경우 19.9톤으로 실측된 장력 20.0톤과 거의 유사하였다. 또한 예인삭의 길이를 30 m에서 60 m로 변경하여 실시한 예인 결과 장력이 거의 유사한 패턴을 보이고 있어 예인삭을 30 m 이상 사용할 경우 배출류에 의한 영향은 거의 없는 것으로 판단된다.

A lateral load pattern based on energy evaluation for eccentrically braced frames

  • Fakhraddini, Ali;Fadaee, Mohammad Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.623-632
    • /
    • 2018
  • Performance-Based Plastic Design (PBPD) method has been recently developed to evaluate the behavior of structures in different performance levels. The PBPD method utilizes a base shear force and a lateral load pattern that are estimated based on energy and yielding mechanism concepts. Using of current lateral force pattern results in weak structural members in upper stories of a structure so that the values of the story drift in these stories are larger than the target drift, particularly in high-rise buildings. Therefore, such distribution requires modifications to overcome this drawback. This paper proposes a modified lateral load pattern for steel Eccentrically Braced Frames (EBFs) based on parametric study. In order to achieve the modified load pattern, a group of 26 EBFs has been analyzed under a set of 20 earthquake ground motions. Additionally, results of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to derive the new load pattern. To prove the efficiency of present study, three EBFs as examples were designed by modified pattern and current PBPD distribution. Inelastic dynamic analyses results showed that the story drifts using modified lateral load pattern were well within the target values in comparison with current pattern in PBPD, particularly where the effect of the height is significant. The modified load pattern reduces the possibility of underdesigning in upper levels and overdesigning in lower levels of the frames.

Spin Signals in Lateral Spin Valves with Double Nonmagnetic Bottom Electrodes

  • Lee, B.C.
    • Journal of Magnetics
    • /
    • 제13권3호
    • /
    • pp.81-84
    • /
    • 2008
  • Spin injection and detection in lateral spin valves with double nonmagnetic bottom electrodes are investigated theoretically. Spin-polarized current injected from a magnetic electrode is split to two bottom electrodes, and nonlocal spin signals between the other magnetic electrode and the nonmagnetic electrodes are calculated from drift-diffusion equations. It is shown that the spin signal is approximately proportional to the associated current in the electrode.

수정된 수평 전개 모델을 이용한 SC-PMOSFET의 기판 전류와 게이트 전류의 해석적 모델 (An Analytical Models for Substrate Current and Gate Current Using Modified Lateral Electric Field Model for Surface-Channel PMOSFET's)

  • 양광선;박종태;김봉렬
    • 전자공학회논문지A
    • /
    • 제31A권1호
    • /
    • pp.48-53
    • /
    • 1994
  • In this paper, we present the analytical models for substrate current and gate current of stressed SC-PMOSFET using the change of the lateral electric field distribution due to the trapped electron. Calculated Isub and Ig of stressed SC-PMOSFET agree with experimental data. Our model can be very useful explaining the logarithmic time dependence of Isub and Ig. and also the trapped electron distribution.

  • PDF

고차진동모드의 영향을 고려한 충지진하중 (The Effect of Higher Vibration Modes on the Design Seismic Load)

  • 이동근;이석용;신용우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.73-78
    • /
    • 1990
  • In current practice of earthquake resistant design the equivalent lateral force procedure is widely used for its simplicity and convenience. But the equivalent lateral force procedure is derived based on the assumption that the dynamic behavior of the structure is governed primarily by the fundamental vibration mode. Therefore proper prediction of dynamic responses of the structure is unreliable using the equivalent lateral force procedure when the effect of higher vibration modes on the dynamic behavior is negligible. In this study design seismic load which can reflect the effect of higher vibration modes is proposed from the point of view of proper assessment of story shears which have the major influence on the design moment of beams and columns. To evaluate the effect of higher modes, differences between the story force based on the equivalent lateral force procedure specified in current earthquake resistance building code and the one based on modal analysis using design spectrum are examined. From these results improved design seismic load for the equivalent lateral force procedure which can reflect the effect of higher vibration modes is proposed.

  • PDF

전류포화특성을 갖는 새로운 이중게이트 수평형 사이리스터의 순방향 특성 (The Forward Characteristics of A New Lateral Thyristor with Current Saturation)

  • 이유상;최연익;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.773-776
    • /
    • 1999
  • A newly proposed lateral dual-gate thyristor was fabricated and measured, which has excellent current saturation characteristics of $1200A/cm^2$ even at an anode-gate voltage of 29V, through the elimination of the structurally existing parasitic thyristor. And through the comparison with the LIGBT, the excellent current saturation characteristics of a newly proposed device was verified.

  • PDF

A Compensator for Lateral Current Reduction Applied to Autonomously Controlled UPSs Connected in Parallel

  • Sato Kazuhide Kazuhide;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.312-318
    • /
    • 2005
  • This paper presents a compensator for reduction of the reactive lateral current in multiple autonomously controlled uninterruptible power supplies (UPS) connected in parallel. This compensator acts directly on the control equation for voltage amplitude and it provides an improved current distribution especially in the case of parallel connection of UPSs with different output power ratings. Observations show that the original control equation for output voltage amplitude is efficient for voltage regulation but it causes great variation of voltage levels. A compensator with the same structure is added to counterbalance the variation caused by the original control equation. Simulations show promising results with the employment of the proposed compensator. Our simulations are confirmed by experimental results using three UPSs with different output ratings and voltage limiters ($1\%$) connected in parallel under various conditions.