• Title/Summary/Keyword: Power of test

Search Result 10,057, Processing Time 0.054 seconds

An Efficient Technique to Improve Compression for Low-Power Scan Test Data (저전력 테스트 데이터 압축 개선을 위한 효과적인 기법)

  • Song, Jae-Hoon;Kim, Doo-Young;Kim, Ki-Tae;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.104-110
    • /
    • 2006
  • The huge test data volume, test time and power consumption are major problems in system-on-a-chip testing. To tackle those problems, we propose a new test data compression technique. Initially, don't-cares in a pre-computed test cube set are assigned to reduce the test power consumption, and then, the fully specified low-power test data is transformed to improve compression efficiency by neighboring bit-wise exclusive-or (NB-XOR) scheme. Finally, the transformed test set is compressed to reduce both the test equipment storage requirements and test application time.

Investigation on Intermittent Life Testing Program for IGBT

  • Cheng, Yu;Fu, Guicui;Jiang, Maogong;Xue, Peng
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.811-820
    • /
    • 2017
  • The reliability issue of IGBT is a concern for researchers given the critical role the device plays in the safety of operations of the converter system. The reliability of power devices can be estimated from the intermittent life test, which aims to simulate typical applications in power electronics in an accelerated manner to obtain lifetime data. However, the test is time-consuming, as testing conditions are not well considered and only rough provisions have been made in the current standards. Acceleration of the test by changing critical test conditions is controversial due to the activation of unexpected failure mechanisms. Therefore, full investigations were conducted on critical test conditions of intermittent life test. A design optimization process for IGBT intermittent life testing program was developed to save on test times without imposing additional failure mechanisms. The applicability of the process has been supported by a number of tests and failure analysis of the test results. The process proposed in this paper can guide the test process for other power semiconductors.

Study on the Report Conformance Test of IEC 61850 based IED (IEC 61850기반 IED 대상 리포트 적합성 시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, J.H.;Song, I.J.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.241-242
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project, "The verification of Performance of the Substation Automation System and Its Field Test". This paper presents reporting services of IEC 61850-8-1 and related UCA Test procedures, reporting test items are widely divided into unbuffered report and buffered report and this paper is dealing with unbuffered report.

  • PDF

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.

A study on the developing the diagnosis technology and expert system in fossil power plant (화력발전설비 진단기술 및 전문가 시스템개발에 관한 연구)

  • Baik, Young-Min;Jeong, Hee-Don;Shin, Eun-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.642-648
    • /
    • 2008
  • In order to analyze the causes of fossil power plant facilities due to a degradation and corrosion, artificial degraded materials composed of the facilities were manufactured. Various experiment were performed based on mechanical test, microstructure observation, hardness test, electrochemical potentiokinetic reactivation test(EPR) and corrosion scale thickness measurement test. The master curves were write out using Larson-Miller parameter to evaluate the degree of degradation with the above diagnosis methods. These data were applied to materials database of fossil power plant diagnosis. Finally expert system on the fossil power plant diagnosis was developed using the master curves and diagnosis algorithms.

  • PDF

Power Investigation of the Entropy-Based Test of Fit for Inverse Gaussian Distribution by the Information Discrimination Index

  • Choi, Byungjin
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.6
    • /
    • pp.837-847
    • /
    • 2012
  • Inverse Gaussian distribution is widely used in applications to analyze and model right-skewed data. To assess the appropriateness of the distribution prior to data analysis, Mudholkar and Tian (2002) proposed an entropy-based test of fit. The test is based on the entropy power fraction(EPF) index suggested by Gokhale (1983). The simulation results report that the power of the entropy-based test is superior compared to other goodness-of-fit tests; however, this observation is based on the small-scale simulation results on the standard exponential, Weibull W(1; 2) and lognormal LN(0:5; 1) distributions. A large-scale simulation should be performed against various alternative distributions to evaluate the power of the entropy-based test; however, the use of a theoretical method is more effective to investigate the powers. In this paper, utilizing the information discrimination(ID) index defined by Ehsan et al. (1995) as a mathematical tool, we scrutinize the power of the entropy-based test. The selected alternative distributions are the gamma, Weibull and lognormal distributions, which are widely used in data analysis as an alternative to inverse Gaussian distribution. The study results are provided and an illustrative example is analyzed.

A Test Vector Reordering for Switching Activity Reduction During Test Operation Considering Fanout (테스트시 스위칭 감소를 위해 팬 아웃을 고려한 테스트벡터 재 정렬)

  • Lee, Jae-Hoon;Baek, Chul-Ki;Kim, In-Soo;Min, Hyoung-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1043-1048
    • /
    • 2011
  • Test vector reordering is a very effective way to reduce power consumption during test application. But, it is time-consuming and complicated processes, and it does not consider internal circuit structure, which may limit the effectiveness. In this paper, we order test vectors using fanout count of primary inputs that consider the internal circuit structure, which may reduce the switching activity. Then, we reorder test test vectors again by using Hamming distance between test vectors. We proposed FOVO algorithm to perform these two ideas. FOVO is an effective way to reduce power consumption during test application. The algorithm is applied to benchmark circuits and we get an average of 3.5% or more reduction of the power consumption.

Field Test for Performance Evaluation of a Tubular Turbine in Marine Small Hydro Power Plant (해양소수력발전소 튜블러 수차 성능평가를 위한 현장시험)

  • Hwang, Yeong-Ho;Lee, Young-Ho;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1070-1077
    • /
    • 2011
  • This study includes field test results for performance evaluation of a tubular turbine in marine small hydro power plant. Minimum output power of the tested turbine generator is examined with using of the measured effective head, output power and efficiency. For the rated and maximum output power tests, corrected values from the result of turbine model test are used for the performance evaluation, because experimental conditions of field test at the rated and maximum output powers are restricted correctly. Performance of the test turbine shows good conformance with the suggested guarantee values of output power and efficiency at the measured points of minimum, rated and maximum output power.

Test Scheduling Algorithm of System-on-a-Chip Using Extended Tree Growing Graph (확장 나무성장 그래프를 이용한 시스템 온 칩의 테스트 스케줄링 알고리듬)

  • 박진성;이재민
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.93-100
    • /
    • 2004
  • Test scheduling of SoC (System-on-a-chip) is very important because it is one of the prime methods to minimize the testing time under limited power consumption of SoC. In this paper, a heuristic algorithm, in which test resources are selected for groups and arranged based on the size of product of power dissipation and test time together with total power consumption in core-based SoC is proposed. We select test resource groups which has maximum power consumption but does not exceed the constrained power consumption and make the testing time slot of resources in the test resource group to be aligned at the initial position in test space to minimize the idling test time of test resources. The efficiency of proposed algorithm is confirmed by experiment using ITC02 benchmarks.

Data Correction of Wind Tunnel Test Results for Smart UAV Power Model (스마트무인기 파워효과 풍동시험 데이터 보정)

  • Cho, Tae-Hwan;Chung, Jin-Deog;Choi, Sung-Wook;Kim, Yang-Won;Chang, Byeong-Hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.2
    • /
    • pp.130-135
    • /
    • 2007
  • Wind tunnel test for Smart UAV power model has been conducted at KARI LSWT for about 3 months. The static model is used for the base plane and the power effect of tilt rotor is simulated by the tilt-rotor test rig installed in the test section. Although the genuine power effect is the difference between power-on and off tests. The existence of struts for power effect test produced unwanted form of interference and caused the change in flow angularity. To precisely evaluate power effect, a special approach is applied to Smart UAV test.