• Title/Summary/Keyword: Power Shift

Search Result 1,057, Processing Time 0.043 seconds

Analysis on the Shift Characteristics of Semi-Spherical CVT using 2-dimensional Friction Model (2차원 마찰모델을 이용한 구면무단변속기의 변속특성해석)

  • Kong, Jin-Hyung;Lim, Won-Sik;Park, Yeon-Gil;Kim, Jung-Yun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.103-109
    • /
    • 2008
  • Semi-spherical CVT(SS-CVT) is one of friction drives, which transmits power via the friction force between a spherical shaped variator and output disks. The variator varies the speed ratio of SS-CVT continuously as well as transmits input power into the output shaft. Therefore two friction forces are normally applied on the variator; one is the longitudinal friction force for power transmission and the other is the lateral for shifting. In order to investigate the dynamic behavior of SS-CVT, we introduced a numerical model of 2-dimensional friction force using a function of slip ratio and slip angle. And a dynamic model, which describes the shifting mechanism of SS-CVT, is developed through 3-dimensional vector analysis. Finally we presented numerical results of the shift characteristics focused on the transient behavior of the variator's slip ratio and slip angle. The numerical results also show the typical CVT shifting characteristics of SS-CVT and stable shifting behaviors of the variator.

A New DC-DC Converter Topology For High-Efficiency Electric Vehicle Rapid Chargers (전기전동차 급속충전기 고효율화를 위한 새로운 DC-DC 컨버터 토폴로지)

  • Kim, Jin-Hak;Lee, Woo-Seok;Choi, Seung-Won;Lee, Jun-Young;Lee, Il-Oun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.182-189
    • /
    • 2018
  • LLC resonant converters or phase-shift full-bridge converters have been widely used as DC - DC converters for rapid charging of electric vehicles (EVs). However, these converters present critical disadvantages, including a large circulating current, which can hinder efficiency and miniaturization in EV battery charger applications. In this paper, a new DC - DC converter topology is proposed for EV rapid chargers. The proposed converter can operate at high frequency despite a high rated power capacity of over 20kW, and the problem of circulating current can be minimized during the entire battery charging time. Owing to these advantages, the proposed converter can achieve a high conversion efficiency of over 97% for EV rapid charger applications. The performance of the proposed converter is verified with 20kW prototypes in this study.

Digital-To-Phase-Shift PWM Circuit for Full Digital Controlled FB DC/DC Converter

  • Kim, Eun-Soo;Choi, Hae-Young;Park, Soon-Gu;Kim, Tae-Jin;Kim, Yoon-Ho;Lee, Jae-Hak
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.442-446
    • /
    • 1998
  • With the advent of the high-speed microprocessor and DSP, the possibility of executing a control strategy in digital domain has become a reality. By the use of the DSP and microprocessor controller, many high power converters such as especially inverter and motor drive system may be enhanced resulting in the improved robustness to EMI, the ability to communicate the operating conditions and the ease of adjusting the control parameters. But, the digital controller using DSP or microprocessor is not applied in the high frequency switching power supplies, especially full bridge dc/dc converter. So, this paper presents the method and realization of designing a digital-to-phase shift PWM circuit for full digital controlled phase-shifted full bridge dc/dc converter with zero voltage switching. The operating principles, simulation and experimental results will be presented.

  • PDF

Sensorless Driving System of Switched Reluctance Motor Using Impressed Voltage Pulse (전압펄스 주입방식을 이용한 SRM 센서리스 제어)

  • Yoon Yong-Ho;Kim, Yuen-Chung;Won Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.388-396
    • /
    • 2005
  • SRM has not been put into practical applications widely because of its large torque ripple, acoustic noise and low power factor. In addition, a traditional position sensor is needed for the drive control. So we propose an improved sensorless drive method of Switched Reluctance Motors using impressed voltage pulses. Conventional impressed voltage pulse method has a problem of phase delay because of low-pass filter. So in this paper we propose an unproved sensorless driving method based on the impressed voltage pulse using new pulse-shift circuit technique that overcomes the phase delay and start-up problem. Proposed method is implemented in a simple analog circuit instead of using an expensive DSP.

Simplified 2-D Analytical Model for Winding Loss Analysis of Flyback Transformers

  • Zhang, Junming;Yuan, Wei;Zeng, Hulong;Qian, Zhaoming
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.960-973
    • /
    • 2012
  • The winding loss analysis of a flyback transformer is difficult and ambiguous because the primary side current and the secondary side current differs both in shape and phase, especially for DCM (Discontinuous Conduction Mode) operation. Meanwhile, the fringing field caused by the air gaps further makes the traditional 1-D loss analysis model not directly applicable. The paper gives a thorough investigation into the phase shift of winding currents, which indicates that the phase shift of the high order harmonics is still close to $180^{\circ}$ out-of-phase. Based on the analysis, a simplified 2-D winding loss analytical model for flyback transformers considering the effects of low order harmonics is proposed. By neglecting the y components of the fringing field, the proposed model has an acceptable accuracy and a simple form that is similar to the conventional 1-D model. The power loss calculated with the proposed analysis model is verified by FEA (Finite Element Analysis) simulations and experimental results.

Study on ESS Operation Plan for Energy Reduction in Industrial Customer (산업용 수용가에서 에너지절감을 위한 ESS 운영 방안에 관한 연구)

  • Yu, Soon-Jeong;Lee, An-gi;Baek, Jeong-Seon;Cha, Dae-Joong;KIm, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1152-1158
    • /
    • 2018
  • In this paper, Optimal operation plan through load analysis of industrial end-user is suggested. It calculated economic feasibility of ESS with detailed power lad analysis and conditions. Generally, if the latest maximum power is less than 30% of contracted power, it can not be peak shaving operation plan. and if the peak load level stays stead for 24 hours, it is difficult peak shaving for ESS. In addition to, When the peak load is occurred in summer or winter, a hybrid operation method combining the peak shaving plan and the time shift method is proposed. Therefore, When ESS is installed in industrial electrical customer, it is achieved best effect through the optimal operation plan.

Multi-Service Optical Transmission Equipment with LAN Interface for Electrical Power System (전력용 LAN 지원 다기능 광 전송장치 개발)

  • Kim, Jae-Sung;Min, Nam-Ki;Lee, Sung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1901-1902
    • /
    • 2006
  • In recent years, it has been a worldwide trend that many power utilities gave their attention to develop and operate their power plants, substation and distribution systems. Following this trend, KEPCO(Korea Electric Power Corporation) has developed many electric automation systems with various communication networks. It has been natural that the automation systems are just focused on to remote devices when they come to be designed. But, we have to shift the focus to the automation system itself. We have developed the Multi-service Optical Transmission System (M-OTS) for electrical power systems. It can be adopt to not only distribution power field but also the transmission power field. The result strongly shows that the system is potentially beneficial in reliability, speed, and expandability. This paper presents some of initial design efforts and results toward a KEPCO's communication system in distribution areas.

  • PDF

Predictive Factors of Health promotion behaviors of Industrial Shift Workers (산업장 교대근무 근로자의 건강증진행위 예측요인)

  • Kim, Young-Mi
    • Korean Journal of Occupational Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.13-30
    • /
    • 2002
  • Industrial shift workers feels suffer mental stresses which are caused by unfamiliar day sleep, noisy environment, sleeping disorder by bright light, unusual contacts with family, difficulty in meeting with friends or having formal social meetings and other social limitations such as the use of transportation. Such stresses influence health of the workers negatively. Thus the health promotion policy for shift workers should be made considering the workers' ways of living and shift work specially. This study attempted to provide basic information for development of the health promotion program for industrial shift workers by examining predictive factors influencing health promotion behaviors of those workers. In designing the study, three power generation plants located in Pusan and south Kyungsang province were randomly selected and therefrom 280 workers at central control, boiler and turbine rooms and environmental chemistry parts whose processes require shift works were sampled as subjects of the study. Data were collected two times from September 17 to October 8, 1999 using questionnaires with helps of safety and health managers of the plants. The questionnaires were distributed through mails or direct visits. Means for the study included the measurement tool of health promotion behavior provided by Park(1995), the tool of self-efficacy measurement by Suh(1995), the tool of internal locus of control measurement by Oh(1987), the measurement tool of perceived health state by Park(1995) and the tool of social support measurement by Paek(1995). The collected data were analyzed using SPSS program. Controlling factors of the subjects were evaluated in terms of frequency and percentage ratio Perceived factors and health promotion behaviors of the subjects were done so in terms of mean and standard deviation, and average mark and standard deviation, respectively. Relations between controlling and perceived factors were analyzed using t-test and ANOVA and those between perceived factors and the performance of health promotion behaviors, using Pearson's Correlation Coefficient. The performance of health promotion behaviors was tested using t-test, ANOVA and post multi-comparison (Scheffe test). Predictive factors of health promotion behavior were examined through the Stepwise Multiple Regression Analysis. Results of the study are summarized as follows. 1. The performance of health promotion behaviors by the subjects was evaluated as having the value of mean, $161.27{\pm}26.73$ points(min.:60, max.:240) and average mark, $2.68{\pm}0.44$ points(min.:1, max.:4). When the performance was analyzed according to related aspects, it showed the highest level in harmonious relation with average mark, $3.15{\pm}.56$ points, followed by hygienic life($3.03{\pm}.55$), self-realization ($2.84{\pm}.55$), emotional support($2.73{\pm}.61$), regular meals($2.71{\pm}.76$), self-control($2.62{\pm}.63$), health diet($2.62{\pm}.56$), rest and sleep($2.60{\pm}.59$), exercise and activity($2.53{\pm}.57$), diet control($2.52{\pm}.56$) and special health management($2.06{\pm}.65$). 2. In relations between perceived factors of the subjects(self-efficacy, internal locus of control, perceived health state) and the performance of health promotion behaviors, the performance was found having significantly pure relations with self-efficacy (r=.524, P=.000), internal locus of control (r=.225, P=.000) and perceived health state(r=.244, P=.000). The higher each evaluated point of the three factors was, the higher the performance was in level. 3. When relations between the controlling factors(demography-based social, health-related, job-related and human relations characteristics) and the performance of health promotion behaviors were analyzed, the performance showed significant differences according to marital status (t=2.09, P= .03), religion(F=3.93, P= .00) and participation in religious activities (F=8.10, P= .00) out of demography-based characteristics, medical examination results (F=7.20, P= .00) and methods of the collection of health knowledge and information(F=3.41, P= .01) and methods of desired health education(F=3.41, P= .01) out of health-related characteristics, detrimental factors perception(F=4.49, P= .01) and job satisfaction(F=8.41, P= .00) out of job-related characteristics and social support(F=14.69, P= .00) out of human relations characteristics. 4. The factor which is a variable predicting best the performance of health promotion behaviors by the subjects was the self-efficacy accounting for 27.4% of the prediction, followed by participation in religious activities, social support, job satisfaction, received health state and internal locus of control in order all of which totally account for 41.0%. In conclusion, the predictive factor which most influence the performance of health promotion behaviors by shift workers was self-efficacy. To promote the sense, therefore, it is necessary to develop the nursing intervention program considering predictive factors as variables identified in this study. Further industrial nurses should play their roles actively to help shift workers increase their capability of self-management of health.

  • PDF

A Class E Power Oscillator for 6.78-MHz Wireless Power Transfer System

  • Yang, Jong-Ryul
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.220-225
    • /
    • 2018
  • A class E power oscillator is demonstrated for 6.78-MHz wireless power transfer system. The oscillator is designed with a class E power amplifier to use an LC feedback network with a high-Q inductor between the input and the output. Multiple capacitors are used to minimize the variation of the oscillation frequency by capacitance tolerance. The gate and drain bias voltages with opposite characteristics to make the frequency shift of the oscillator are connected in a resistance distribution circuit located at the output of the low drop-out regulator and supplied bias voltages for class E operation. The measured output of the class E power oscillator, realized using the co-simulation, shows 9.2 W transmitted power, 6.98 MHz frequency and 86.5% transmission efficiency at the condition with 20 V $V_{DS}$ and 2.4 V $V_{GS}$.

A New Low Power Scan BIST Architecture Based on Scan Input Transformation Scheme (스캔입력 변형기법을 통한 새로운 저전력 스캔 BIST 구조)

  • Son, Hyeon-Uk;Kim, You-Bean;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.43-48
    • /
    • 2008
  • Power consumption during test can be much higher than that during normal operation since test vectors are determined independently. In order to reduce the power consumption during test process, a new BIST(Built-In Self Test) architecture is proposed. In the proposed architecture, test vectors generated by an LFSR(Linear Feedback Shift Resister) are transformed into the new patterns with low transitions using Bit Generator and Bit Dropper. Experiments performed on ISCAS'89 benchmark circuits show that transition reduction during scan testing can be achieved by 62% without loss of fault coverage. Therefore the new architecture is a viable solution for reducing both peak and average power consumption.