• 제목/요약/키워드: Feedthrough

검색결과 37건 처리시간 0.026초

가스 절연 시험용 체임버 개발 연구 (A Study on the Development of a 1800KV Testing Chamber for Gas Insulation)

  • 조연옥;최병주;김광수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.405-408
    • /
    • 1989
  • A 1800KV testing chamber for gas insulation has been developed. To develop the chamber, all parts consisting of the chamber, namely, bushing, main chamber, shield, conductor bus, inspection window, feedthrough, and spacer have been designed based on numerical electric field analysis. This paper presents the detailed design philosophy and methods of the chamber.

  • PDF

고정밀 CMOS sample-and-hold 증폭기 설계 기법 및 성능 비교 (The design of high-accuracy CMOS sampel-and-hold amplifiers)

  • 최희철;장동영;이성훈;이승훈
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.239-247
    • /
    • 1996
  • The accuracy of sample-and-hold amplifiers (SHA's) empolying a CMOS process in limited by nonideal factors such as linearity errors of an op amp and feedthrough errors of switches. In this work, after some linearity improvement techniques for an op amp are discussed, three different SHA's for video signal processing are designed, simulated, and compared. The CMOS SHA design techniques with a 12-bit level accuracy are proposed by minimizing cirucit errors based on the simulated results.

  • PDF

1.5-비트 비트 셀을 이용한 새로운 구조의 CMOS 전류모드 아날로그-디지털 변환기 (A New Architecture of CMOS Current-Mode Analog-to-Digital Converter Using a 1.5-Bit Bit Cell)

  • 최경진;이해길;나유찬;신홍규
    • 한국음향학회지
    • /
    • 제18권2호
    • /
    • pp.53-60
    • /
    • 1999
  • 본 논문에서는 CSH(Current Sample-and-Hold)와 CCMP(Current Comparator)로 구성된 1.5-비트 비트 셀을 이용한 새로운 구조의 CMOS IADC(Current-mode Analog-to-Digital Convener)를 제안한다. 전체적인 IADC의 선형성 향상을 위하여 CFT(Clock Feedthrough)가 제거된 9-비트 해상도 CSH를 설계하여 각 비트 셀 전단에 배치하였다. 제안한 IADC를 구성하는 비트 셀은 2개의 래치 CCMP를 사용하기 때문에 디지털 교정 로직이 간소화되고 소비전력이 감소된다. 또한 IADC를 구성하는 모든 블록들의 회로는 MOS 트랜지스터로만 설계되었기 때문에 혼성모드 집적화에 유리하다. 제안한 IADC를 현대 0.8 ㎛ CMOS 파라미터로 HSPICE 시뮬레이션 결과, 20Ms/s에서 100 ㎑의 입력 신호에 대한 SNR은 43 dB로 7-비트의 해상도를 만족하였고 27 ㎽의 소비전력 특성을 나타냈다.

  • PDF

Support MOS Capacitor를 이용한 Current Transfer 구조의 전류 메모리 회로 (Current Transfer Structure based Current Memory using Support MOS Capacitor)

  • 김형민;박소연;이대니얼주헌;김성권
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.487-494
    • /
    • 2020
  • 본 논문에서는 정적소비전력을 줄이며, 전류 모드 신호처리의 장점을 최대로 올릴 수 있는 전류 메모리 회로 설계를 제안한다. 제안하는 전류 메모리 회로는 기존의 전류 메모리 회로가 갖는 Clock-Feedthrough와 Charge-Injection 등으로 인해 데이터 저장 시간이 길어지면서 전류 전달 오차가 심해지는 문제를 최소화하며, 저전력 동작이 가능한 Current Transfer 구조에 밀러 효과(Miller effect)를 극대화하는 Support MOS Capacitor를 삽입하는 설계로, 저장 시간에 따르는 개선된 전류 전달 오차를 보였다. 매그나칩/SK하이닉스 0.35㎛ 공정으로 칩 제작을 통한 실험 결과, 저장 시간에 따르는 전류 전달 오차가 5% 이하로 개선되는 것을 검증하였다.

12비트 100 MS/s로 동작하는 S/H(샘플 앤 홀드)증폭기 설계 (A Design of 12-bit 100 MS/s Sample and Hold Amplifier)

  • 허예선;임신일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.133-136
    • /
    • 2002
  • This paper discusses the design of a sample-and -hold amplifier(SHA) that has a 12-bit resolution with a 100 MS/s speed. The sample-and-hold amplifier uses the open-loop architecture with hold-mode feedthrough cancellation for high accuracy and high sampling speed. The designed SHA is composed of input buffer, sampling switch, and output buffer with additional amplifier for offset cancellation Hard Ware. The input buffer is implemented with folded-cascode type operational transconductance Amplifier(OTA), and sampling switch is implemented with switched source follower(SSF). A spurious free dynamic range (SFDR) of this circuit is 72.6 dB al 100 MS/s. Input signal dynamic range is 1 Vpp differential. Power consumption is 65 ㎽.

  • PDF

박막 공정을 이용한 초소형 내시경의 MicroWiring System의 개발 (The Development of Micro Wiring System for Micro Active Endoscope)

  • 정석;장준근;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1997
  • In the field of Micro-Mechanics, it has been known diffcult to integrate the micro-machine with sensor and source line for the conventional copper line cnanot be used in compact and small size. We developed a system to make thethin copper film as a connect line on the poyurethane pipe (2mm in diameter) by the evaporation technique. This system consists of an evaporation chamber two long branches, substrate hoider and a Linear-Rotary motion feed feedthrough. The results showed that thin copper film coated polyurethanc pipe could be applied th the small medical devices such as the micro active endoscope.

  • PDF

분산 저차 구조의 $H_{\infty}$ 제어기 설계를 위한 시스템의 간략화 방법 (Simplifying method for the design of decentralized reduced order $H_{\infty}$ controllers)

  • 조철형;서진헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.933-935
    • /
    • 1996
  • The simplifying method for the design of decentralized reduced order $H_{\infty}$ controller is considered in this paper. When the controller is reconstructed for the original system, the decentralized condition of the controller for the transformed system is generally destroyed with older simplifying method. In designing the decentralized controller, direct output feedthrough terms give some difficulties by using other station's input information. We proposed a new solution for this problem.

  • PDF

피드스루용 세라믹의 선삭 가공 특성에 관한 연구 (Turning the Machining Characteristics of Feed-through Ceramics)

  • 박세진;하준태;양동호;이종찬
    • 한국기계가공학회지
    • /
    • 제19권10호
    • /
    • pp.81-86
    • /
    • 2020
  • A ceramic vacuum chamber feedthrough ceramic insulator is made of Al2O3; the manufacturing process involves filling alumina powder into a urethane mold and pressing it with a rubber press to produce a molded body. Thereafter, manufacturing is completed through primary shape processing, sintering, and secondary shape processing in the green body, which is a pressurized molding body, This work is intended to prevent defects in the first shape processing by improving the ceramic insulator in the green body, and to improve the productivity of the ceramic insulator by determining the optimal processing conditions.

전류 부정합을 줄인 새로운 전하 펌프 (New Charge Pump for Reducing the Current Mismatch)

  • 이재환;정항근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.469-471
    • /
    • 2008
  • 전하 펌프는 위상 고정 루프의 성능에 영향을 준다. 전하 펌프 설계에 있어서 전류 부정합, 전하 공유, 전하 주입, 누설 전류 등을 고려할 필요가 있다. 본 논문에서는 기존의 고속 전하 펌프의 전류 정합성을 개선한 새로운 전하 펌프 회로를 제안하였다. 전류 부정합을 줄이기 위해 주로 사용되는 간단한 방법으로는 캐스코드를 이용하여 전하 펌프의 출력 저항을 증가시키는 방법이 있다. 그러나 캐스코드 방법을 사용하면 전하펌프의 출력 범위에 제약을 받게 되므로 전원 전압이 낮아짐에 따라 적용하기가 힘들어진다는 단점이 있다. 따라서 본 논문에서는 캐스코드를 적용하지 않고 연산증폭기를 사용하여 전하펌프의 출력 범위 전체에서 우수한 전류 정합 특성을 갖는 회로를 제안하였다.

  • PDF

EFT IEC801-4 대책용 전원케이블의 개발에 관한 연구 (A study on development of Power Cable countermeasuring EFT IEC801-4)

  • 김형근;배대환;민경찬;김동일
    • 한국항해학회지
    • /
    • 제19권2호
    • /
    • pp.107-113
    • /
    • 1995
  • Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( $C_y$ type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.

  • PDF