• Title/Summary/Keyword: Drain Work

Search Result 128, Processing Time 0.024 seconds

Performance Improvement of Amorphous In-Ga-Zn-O Thin-film Transistors Using Different Source/drain Electrode Materials (서로 다른 소스/드레인 전극물질을 이용한 비정질 In-Ga-Zn-O 박막트랜지스터 성능향상)

  • Kim, Seung-Tae;Cho, Won-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • In this study, we proposed an a-IGZO (amorphous In-Ga-Zn-O) TFT (thin-film transistor) with off-planed source/drain structure. Furthermore, two different electrode materials (ITO and Ti) were applied to the source and drain contacts for performance improvement of a-IGZO TFTs. When the ITO with a large work-function and the Ti with a small work-function are applied to drain electrode and source contact, respectively, the electrical performances of a-IGZO TFTs were improved; an increased driving current, a decreased leakage current, a high on-off current ratio, and a reduced subthreshold swing. As a result of gate bias stress test at various temperatures, the off-planed S/D a-IGZO TFTs showed a degradation mechanism due to electron trapping and both devices with ITO-drain or Ti-drain electrode revealed an equivalent instability.

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Breakdown Voltage and On-resistance Characteristics of N-channel EDMOS with Dual Work Function Gate (이중 일함수 구조를 적용한 N-채널 EDMOS 소자의 항복전압 및 온-저항 특성)

  • Kim, Min-Sun;Baek, Ki-Ju;Kim, Yeong-Seuk;Na, Kee-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.671-676
    • /
    • 2012
  • In this paper, TCAD assessment of 30-V class n-channel EDMOS (extended drain metal-oxide-semiconductor) transistors with DWFG (dual work function gate) structure are described. Gate of the DWFG EDMOS transistor is composed of both p- and n-type doped region on source and drain side. Additionally, lengths of p- and n-type doped gate region are varied while keeping physical channel length. Two-dimensional device structures are generated trough TSUPREM-4 and their electrical characteristics are investigated with MEDICI. The DWFG EDMOS transistor shows improved electrical characteristics than conventional device - i.e. higher transconductance ($g_m$), better drain output current ($I_{ON}$), reduced specific on-resistances ($R_{ON}$) and higher breakdown characteristics ($BV_{DSS}$).

Optimizing Effective Channel Length to Minimize Short Channel Effects in Sub-50 nm Single/Double Gate SOI MOSFETs

  • Sharma, Sudhansh;Kumar, Pawan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.170-177
    • /
    • 2008
  • In the present work a methodology to minimize short channel effects (SCEs) by modulating the effective channel length is proposed to design 25 nm single and double gate-source/drain underlap MOSFETs. The analysis is based on the evaluation of the ratio of effective channel length to natural/ characteristic length. Our results show that for this ratio to be greater than 2, steeper source/drain doping gradients along with wider source/drain roll-off widths will be required for both devices. In order to enhance short channel immunity, the ratio of source/drain roll-off width to lateral straggle should be greater than 2 for a wide range of source/drain doping gradients.

Reduction of Barrier Height between Ni-silicide and p+ source/drain for High Performance PMOSFET (고성능 PMOSFET을 위한 Ni-silicide와 p+ source/drain 사이의 barrier height 감소)

  • Kong, Sun-Kyu;Zhang, Ying-Ying;Park, Kee-Young;Li, Shi-Guang;Zhong, Zhun;Jung, Soon-Yen;Yim, Kyoung-Yean;Lee, Ga-Won;Wang, Jin-Suk;Lee, Hi-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.157-157
    • /
    • 2008
  • As the minimum feature size of semiconductor devices scales down to nano-scale regime, ultra shallow junction is highly necessary to suppress short channel effect. At the same time, Ni-silicide has attracted a lot of attention because silicide can improve device performance by reducing the parasitic resistance of source/drain region. Recently, further improvement of device performance by reducing silicide to source/drain region or tuning the work function of silicide closer to the band edge has been studied extensively. Rare earth elements, such as Er and Yb, and Pd or Pt elements are interesting for n-type and p-type devices, respectively, because work function of those materials is closer to the conduction and valance band, respectively. In this paper, we increased the work function between Ni-silicide and source/drain by using Pd stacked structure (Pd/Ni/TiN) for high performance PMOSFET. We demonstrated that it is possible to control the barrier height of Ni-silicide by adjusting the thickness of Pd layer. Therefore, the Ni-silicide using the Pd stacked structure could be applied for high performance PMOSFET.

  • PDF

A Study on the Characteristics of Construction Noise by Sand Drain Method (Sand Drain 공법에 의한 작업시 발생하는 건설소음의 특성에 관한 연구)

  • Yun, Hae-Dong;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.500-505
    • /
    • 2000
  • Recently, with the increasing of construction works, large construction equipment are used to reduce the term of work and labor cost in construction field. Therefore, construction equipment noise has caused much annoyance for a number of dweller in nearby construction field and it has become a very serious problem in our living environment. Neverthless, in our country, adequite guidelines for the construction equipment noise are very deficiency because of the lack of basic data and insufficient research works. From this point of view, this study attempts to survey the characteristics of attenuation and propagation of Sand Drain Method in construction field. On the basis of measurement value, we analysed about prediction possibility of Sand Drain Method. This study also present a basic data found a effective plans for Sand Drain Method.

  • PDF

The Construction Work Method of Mixed Coal Ash in Ash Pond to Recycle as a Horizontal Drain Material (수평배수재로 재활용하는 회사장 혼합석탄재의 시공 방안)

  • Koh, Yongil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • The design for horizontal drain layer on soft ground starts from the decision that the material could be used or not, by verifying material condition in permeability of horizontal drain material according to the weight percent of the dry soil retained on #200 sieve. In the next step of the design, we estimate the thickness of horizontal drain layer to confirm trafficability of heavy machinery in construction work. Successively, the long-term functionality for good drainage of horizontal drain layer is checked and if needed, some means are considered. In this study, the system to recycle mixed coal ash in ash pond successfully as a horizontal drain material on soft ground is presented through the process and the result of its practical construction work. Namely, the pact is confirmed that mixed coal ash in ash pond should be sorted out by sieve screen to a certain extent and the remainders of this mixed coal ash on sieve openings be recycled, because the amount of finer particles than $75{\mu}m$ contained in mixed coal ash in ash pond is quite massive and irregular depending on the coal power plant or the location in same ash pond. In order to sort at large scale in situ, the dimension of a sieve squre hole and the sort-out method, etc. should be decided before the sort-out process. And, it is described that we need to manufacture classifier to sort out mixed coal ash in ash pond, too.

Gate-to-Drain Capacitance Dependent Model for Noise Performance Evaluation of InAlAs/InGaAs Double-gate HEMT

  • Bhattacharya, Monika;Jogi, Jyotika;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In the present work, the effect of the gate-to-drain capacitance ($C_{gd}$) on the noise performance of a symmetric tied-gate $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ double-gate HEMT is studied using an accurate charge control based approach. An analytical expression for the gate-to-drain capacitance is obtained. In terms of the intrinsic noise sources and the admittance parameters ($Y_{11}$ and $Y_{21}$ which are obtained incorporating the effect of $C_{gd}$), the various noise performance parameters including the Minimum noise figure and the Minimum Noise Temperature are evaluated. The inclusion of gate-to-drain capacitance is observed to cause significant reduction in the Minimum Noise figure and Minimum Noise Temperature especially at low values of drain voltage, thereby, predicting better noise performance for the device.

An Experimental Study on Reducing Condensation in Marine Air Compressors

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.303-308
    • /
    • 2015
  • Compressed air has many uses on board ship, ranging from diesel engine starting to the cleaning of machinery during maintenance. In an effort to enhance the performance of the marine compressed air system, this work studied a way to reduce condensation from the air compressor via experiments. Especially more condensation is produced when the temperature at compressor outlets and the humidity of the air are higher. so in the research, drain production change has been observed by additionally installing the cooling fan on the suction portion of the air to air compressor and this is the method for reducing the compressed air drain that has passed through the compressor. For the result, it was verified that when the cooling fan was used, less drain was made where per hour it was 500.9ml of drain and the measured result after installing the cooling fan was that less drain was made. Other additional and various researches are needed including experiments like silica gel passing through the suction portion afterwards.

Research on the safety working instructions in the retaining wall construction (concrete retaining wall) (옹벽(콘크리트 옹벽)의 안전작업 지침 개요)

  • Oh, Ki-Taek;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.25-33
    • /
    • 2016
  • This guidance purpose is setting Safety Health work instruction for prevent accident such as falling from heights work, collapse and trapped under the heavy equipment and Sediment collapse during retaining wall work by unsder the Industry Safety and Health rules.