DOI QR코드

DOI QR Code

An Experimental Study on Reducing Condensation in Marine Air Compressors

  • Kim, Bu-Gi (Division of Marine Mechatronics, Mokpo National Maritime University) ;
  • Kim, Hong-Ryeol (Training Ship, Mokpo National Maritime University) ;
  • Yang, Chang-Jo (Division of Marine Engineering System, Mokpo National Maritime University) ;
  • Kim, Jun-Ho (Division of Marine Mechatronics, Mokpo National Maritime University)
  • Received : 2015.06.04
  • Accepted : 2015.06.26
  • Published : 2015.06.30

Abstract

Compressed air has many uses on board ship, ranging from diesel engine starting to the cleaning of machinery during maintenance. In an effort to enhance the performance of the marine compressed air system, this work studied a way to reduce condensation from the air compressor via experiments. Especially more condensation is produced when the temperature at compressor outlets and the humidity of the air are higher. so in the research, drain production change has been observed by additionally installing the cooling fan on the suction portion of the air to air compressor and this is the method for reducing the compressed air drain that has passed through the compressor. For the result, it was verified that when the cooling fan was used, less drain was made where per hour it was 500.9ml of drain and the measured result after installing the cooling fan was that less drain was made. Other additional and various researches are needed including experiments like silica gel passing through the suction portion afterwards.

Keywords

References

  1. KR Rules/Guidance(2015), Pt 5, Ch 6, Sec. 11, p. 144.
  2. Lee A. S., Kim Y. C., Jung Y. S. and J. S. Wang(1998), Design of an Air-Cooled High-Pressure 3-Stage Reciprocating Air Compressor, Applied to the Starting of Diesel Engines, The Korean Society of Marine Engineering, Vol. 22, No. 1, pp. 42-51.
  3. Lee K. J., Kim J. S., Lee K. W., Kwon Y. C. and S. H. Hong(2011), Experimental Study on Air Compressor for a Oxygen Generator with Cooling System, The Society of Air-Conditioning and Refrigerating Engineerings of Korea, pp. 1321-1324.
  4. Seong J. W., Choi J. S. and K. H. Cho(2007), Prediction of Performance for Marine Air Compressor, The Korean Society of Marine Engineering, pp. 41-42.
  5. Kim G. W., Park J. O. and H. D. Kim(2014), On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor, Transactions of the Korean Society of Mechanical Engineers, B, Vol. 38, No. 11, pp. 873-879. https://doi.org/10.3795/KSME-B.2014.38.11.873
  6. M. G. Lawrence(2005), The Relationship between Relative Humidity and the Dew point Temperature in Moist Air a Simple Conversion and Applications, Bulletin of the American Meteorological Society, Vol. 86, No. 2, pp. 225-234. https://doi.org/10.1175/BAMS-86-2-225