• Title/Summary/Keyword: Biosensors

Search Result 296, Processing Time 0.019 seconds

Heavy Metal Detection and Removal in Artificial Wastewater Using Two-Component System Based Recombinant Bacteria (Two-component System 기반 재조합균을 이용한 인공폐수에서의 중금속 인지 및 제거)

  • Ravikumar, Sambandam;Hong, Soon-Ho;Yoo, Ik-Keun
    • Korean Journal of Microbiology
    • /
    • v.48 no.3
    • /
    • pp.187-191
    • /
    • 2012
  • Two-component system (TCS)-based bacterial zinc and copper biosensors, in which green fluorescent protein (GFP) is expressed under the control of zraP and cusC promoter in ZraS/R and CusS/R TCS, were evaluated in artificial wastewater. Bacterial biosensors developed in this study efficiently expressed GFP by the recognition of $Zn^{2+}$ and $Cu^{2+}$ in artificial wastewater. Secondly, TCS-based zinc and copper removing bacteria with the peptide displayed on cell surface were examined in artificial wastewater. Zinc and copper removing bacteria expressed the peptide as a fusion protein such as OmpC-ZBP (zinc binding peptide) and OmpC-CBP (copper binding peptide) on the cell surface when sensing exogenous $Zn^{2+}$ and $Cu^{2+}$ through ZraS/R and CusS/R TCS. The recombinant cell expressing metal-adsorbing peptide could efficiently remove copper and zinc (15 and 18 mg/g dry cell weight, respectively) in artificial wastewater. Therefore, it was demonstrated that the TCS-based recombinant cell for the recognition or removal of heavy metal functions well in artificial wastewater environment.

Single-Cell-Imaging-Based Analysis of Focal Adhesion Kinase Activity in Plasma Membrane Microdomains Under a Diverse Composition of Extracellular Matrix Proteins (다양한 ECM 조건하에서의 세포막 미세영역 부위 국소접착인산화효소 활성의 단일세포 이미징 기반 분석)

  • Choi, Gyu-Ho;Jang, Yoon-Kwan;Suh, Jung-Soo;Kim, Heon-Su;Ahn, Sang-Hyun;Han, Ki-Seok;Kim, Eunhye;Kim, Tae-Jin
    • Journal of Life Science
    • /
    • v.32 no.2
    • /
    • pp.148-154
    • /
    • 2022
  • Focal adhesion kinase (FAK) is known to regulate cell adhesion, migration, and mechanotransduction in focal adhesions (FAs). However, studies on how FAK activity is regulated in the plasma membrane microdomains according to the composition of extracellular matrix (ECM) proteins are still lacking. A genetically encoded fluorescence resonance energy transfer (FRET)-based biosensor can provide useful information on the activity of intracellular signals with high spatiotemporal resolution. In this study, we analyzed the FAK activities in lipid raft (detergent-resistant membrane) and non-lipid raft (non-detergent-resistant membrane) microdomains using FRET-based membrane targeting FAK biosensors (FAK-Lyn and FAK-KRas biosensors) under four different ECM protein compositions: glass, type 1 collagen, fibronectin, and laminin. Interestingly, FAK activity in response to laminin in a lipid raft microdomain was lower than that in other ECM conditions. Cells subjected to fibronectin showed higher FAK activity in a lipid raft microdomain than that in a non-lipid raft microdomain. Therefore, this study demonstrates that the FAK activity can be distinctively regulated according to the ECM type and the environment of the plasma membrane microdomains.

Development of single walled-carbon nanotubes based pH sensor using ultra-precision spray method (초정밀 스프레이 방법을 이용한 단일벽 탄소나노튜브 pH센서 개발)

  • Kwon, Jae-Hong;Lee, Kyong-Soo;Lee, Yun-Hi;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.127-133
    • /
    • 2006
  • Recent studies demonstrated the ability of carbon nanotube (CNT) to promote electron transfer reactions of important compounds and to impart higher stability onto electrochemical sensors. CNT-based sensors measured by hydroxyl radical concentration or pH value suggest great promise for biosensors. This paper describes a new method for fabricating a very simple and inexpensive pH sensor compose of single walled-carbon nanotubes (SW-CNTs) using an ultra-precision spray. CNT-based sensor shows pH sensitivity in buffer solution at different pH range. Our experimental results show the sensor responses to pH buffer solution and the conductance of depends on the pH values. These results support application possibility of SW-CNTs based pH sensor for mass production.

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Poly(Dimethylaminoethyl Methacrylate)-Based pH-Responsive Hydrogels Regulate Doxorubicin Release at Acidic Condition

  • Lee, Seung-Hun;You, Jin-Oh
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.202-214
    • /
    • 2015
  • Stimuli-responsive biomaterials that alter their function through sensing local molecular cues may enable technological advances in the fields of drug delivery, gene delivery, actuators, biosensors, and tissue engineering. In this research, pH-responsive hydrogel which is comprised of dimethylaminoethyl methacylate (DMAEMA) and 2-hydroxyethyl methacrylate (HEMA) was synthesized for the effective delivery of doxorubicin (Dox) to breast cancer cells. Cancer and tumor tissues show a lower extracellular pH than normal tissues. DMAEMA/HEMA hydrogels showed significant sensitivity by small pH changes and each formulation of hydrogels was examined by scanning electron microscopy, mechanical test, equilibrium mass swelling, controlled Dox release, and cytotoxicity. High swelling ratios and Dox release were obtained at low pH buffer condition, low cross-linker concentration, and high content of DMAEMA. Dox release was accelerated to 67.3% at pH 5.5 for 6-h incubation at $37^{\circ}C$, while it was limited to 13.8% at pH7.4 at the same time and temperature. Cell toxicity results to breast cancer cells indicate that pH-responsive DMAEMA/HEMA hydrogels may be used as an efficient matrix for anti-cancer drug delivery with various transporting manners. Also, pH-responsive DMAEMA/HEMA hydrogels may be useful in therapeutic treatment which is required a triggered release at low pH range such as gene delivery, ischemia, and diabetic ketoacidosis.

MEMS Technology for Biophotonic Applications (바이오포토닉스응용을 위한 MEMS 미세광학소자의 개발)

  • Jeong, Gi-Hun
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.387-388
    • /
    • 2009
  • Biophotonics is an emerging area in a fusion of biology and photonics, especially in advanced bioimaging, optical biosensors, photomodulation, and biochip optical read-out, and optical manipulation. This emerging area also creates many opportunities for interdisciplinary study of biology and photonics. Micro-Electro-Mechanical-System(MEMS) is an attractive technology in miniaturizing sensors and actuactors. For last decade, it has contributed to the development for active and passive small and integrated optical components in optical communication. Recently, this technology is also merging into biology for high sensitive biosensing and high resolution and fast bioimaging in small form factor. In this talk, some key advantages of small optical components and recent biophotonic MEMS achievement will be discussed for miniaturized advanced biophotonic systems.

  • PDF

Hydrogen Peroxide Sensitive Biosensors Based on Mugwort-Peroxidase Entrapped in Carbon Pastes (탄소반죽에 쑥 과산화효소를 고정한 과산화수소 감응 바이오센서)

  • Yoon, Kil Joong
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.624-629
    • /
    • 2015
  • A biosensor including the homogenized tissue of mugwort embedded in carbon paste, which senses hydrogen peroxide, was constructed and its electrochemical properties were validated using voltammetry. The good linearity of Hanes-Woolf plot implied that the reduction reaction of substrate was catalyzed by mugwort peroxidase at the electrode surface. Also the small value of symmetry factor, 0.28, indicated that electrochemical kinetics of the sensor is very sensitive to the change of electrode potential. Many experimental results collected above proved that the dissociation of hydrogen peroxide is dependent on the catalytic power of mugwort peroxidase qualitatively and quantitatively at the surface of the mugwort electrode. It is our firm belief that the marketed HRP can be replaced with mugwort tissue.

Optimization for Higher Sensitive Measurements of FET-type Sensors (FET센서 감도 향상 측정을 위한 최적화)

  • Sohn, Young-Soo
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.116-119
    • /
    • 2015
  • Field-effect transistor (FET)-based ion or biosensors have been intensively studied so far. Among many measurement methods, the variation of the drain current can be induced when ions or biomolecules are interacted with sensing membranes located on the gate insulator of FET. One of typical FET-type sensors is an ion-sensitive field-effect transistor (ISFET) utilized in this study. In ISFET, the voltage is usually applied to the reference electrode instead of the gate voltage. Firstly, the voltage applied to the reference electrode versus the drain current was observed, and the steepest slope in this graph was found. Using this point, the optimized condition was established for the larger variation of the drain current in the saturated region in response to the variation of the input in the dynamic range.

Biosensor Electrode Manufacturing Technology Using Nano-carbon Materials (나노 탄소물질을 이용한 바이오센서 전극제조 기술)

  • Kim, Ji-Hyun;Bae, Tae-Sung;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Due to human life expectancy of the recent development of medical technology recently, it leads to increase the desire for improving the quality of human life, and grow health concerns and needs. Therefore, in order to prevent the occurrence of disease and to check up a disease quickly, research on the development of a biosensor has been actively processed. One of them, the nano-carbon materials, are very suitable for manufacturing biosensor due to their excellent electrical/mechanical properties. In this review, we introduced the recent studies about preparation methods of carbon electrodes using the carbon nano-materials for biosensors as well as its technological applications.

Sol-gel Material Optimization for Aptamer Biosensors

  • Ahn, Ji-Young;Cho, Min-Jung;Lee, Se-Ram;Park, Jun-Tae;Hong, Seok-Jin;Shin, Sung-Ho;Jeong, Min-Ku;Lee, Dong-Ki;Kim, So-Youn
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.2
    • /
    • pp.100-105
    • /
    • 2008
  • Biochips are a powerful emerging technology for biomedical, environmental applications. Especially, making use of bioseonors in the evaluation of toxicity becomes increasingly important. For biosensor as a toxicity detection, biomolecules like antibodies or aptamers have been developed to specifically capture the toxic target molecules. In addition, the development of optimal chip materials capable of maintaining the activity of embedded biomolecules such as proteins or aptamers has proven challenging. Here, using sol-gel materials, new chip material, whose ability for immobilizing the embedded aptamers and maintaining the ability of embedded aptamers is optimal, was searched. We used sol-gel formulation screening methods previously developed and found the best formulation which shows high sensitive and specific interactions of aptamers. This study results will support the technological advancement for diagnosis and environmental sensor.