Temperature History of Mock-up Mass Concrete Considering Different Heat Generation Due to Mixture Adjustment

수화발열량이 다른 콘크리트조합 모의부재 매스콘크리트의 온도이력 특성

  • Published : 2005.05.01

Abstract

This paper investigated the temperature history of mass concrete mock up structure considering different heat generation by varying with mixture proportion. Setting time difference between high early strength mixture (E-P) and retarding mixture (R-F30) was 14.5hours. Incorporation of $30\%$ of fly ash contributed to $10^{\circ}C$ of hydration heat reduction. In generally used C and D combination, bottom concrete shows earlier hydration, while E-J combination showed reverse tendency and thus, this method can reduce the crack occurrence. Therefore, heat generation difference method has beneficial effect on reducing crack induced by hydration heat resulting from heat generation difference between surface and center section.

Keywords