• Title/Summary/Keyword: growth fire

Search Result 351, Processing Time 0.025 seconds

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

Study on Verification of Applicability for a Warehouse Construction Site using a Fire Risk Assessment Tool (화재위험도 평가 Tool에 의한 물류창고 공사장 적용성 검증에 관한 연구)

  • YongGoo Seo;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.673-688
    • /
    • 2023
  • Purpose: Fires that occur during construction are infrequent, but cause great damage. Recently, with the growth of the logistics and distribution industry, the number of construction sites for new logistics warehouses is increasing, so it was selected as a research subject and research was conducted to reduce accidents at construction sites through the development of a fire risk assessment tool to quantitatively approach fire prevention. Method: A comprehensive fire risk assessment tool was accumulated by classifying the work in progress, classifying combustibles and ignition sources by grade, excluding air (oxygen), which is difficult to control, and additionally substituting evacuation safety. Result: Using the developed and proposed fire risk evaluation tool, excavation work with low fire risk, facility construction with medium fire risk, and finishing work with high fire risk were sampled to derive the result (CGI). Conclusion: In this study, it was possible to establish specific preventive measures and evaluate evacuation safety by controlling physical conditions (combustibles) and energy conditions (ignition sources) according to the risk assessment by developing a tool that can evaluate the risk of 14fire occurrence at construction sites. It is expected that in the future, through the application of the fire risk evaluation tool at construction sites, it will be provided as a criterion for establishing a process plan that can reduce risk and evaluating the adaptability of firefighting equipment.14

A Study on Fire Hazard by Metallic Migration (금속 마이그레이션에 의한 화재 위험성 연구)

  • Choi, Gyeong Won;Hyun, Byoung Soo;Kim, Sun Jae;Lim, Kyu Young;Woo, Seung Woo;Lee, Dong Kyu;Cho, Young Jin;Park, Jong Taek;Goh, Jae Mo;Park, Nam Kyu
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.114-119
    • /
    • 2019
  • We found metallic migration phenomena at the fire scene in Printed circuit board (PCB) of LED light equipment which are commonly used. Accordingly we did this study. In order to generate rapidly metallic migration, we experiment the water drop test under low voltage (3.0 V) and a small amount of water condition. As a results of our experiment, we saw the growth of metallic migration of Copper and checked directly short of the PCB between isolated two poles by Cu migration. Finally we saw the shape of dendrite pattern by Cu migration using Scanning electron microscope (SEM) and analyzed that components via Energy dispersive Spectrometer (EDS).

Analysis of the Wireless Communication Environment in the Narrowed Residential Space for the Fire fighting Operation (소방작전을 위한 협소거주 공간의 무선 통신 환경 분석)

  • Park, Hyun-Ju;Hong, Sang-Beom;Choi, Hyuk-Jo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.242-248
    • /
    • 2017
  • Recently, Population has been concentrated in cities due to rapid economic growth. As a result, urban buildings are becoming more dense, high-rise, and diversified. The shape of these urban buildings increases the risk of fire, accidents and crime. The narrow living space has the characteristic of the unchanged floor. In case of a fire, the living space of the narrow residence is large in the damage because the smoke diffusion rate is fast. The radio wave transmittance and transmission distance of wireless communication used in fire fighting operations vary depending on the type of building materials and buildings. Therefore, this paper analyzes the building materials and structural characteristics of the narrow residential space for efficient fire fighting operations. We have developed a communication environment solution for a narrow residential space for the optimal fire fighting operation through the measurement of the radio wave transmittance and the transmission distance of the wireless communication.

A Study on the Heat Hazard Assessment of Building Wood (건축용 목재의 열 유해성 평가에 대한 연구)

  • Woo, Tae-Young;Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.6-14
    • /
    • 2018
  • This study was carried out with respect to the heat release rate (HRR) properties of building wood. Heat release characteristics were measured using a cone calorimeter (ISO 5660-1) with four kinds of wood. The time to ignition measured after the combustion in $25kW/m^2$ external heat flux was 35 to 55 s. Time to ignition of both lauan and red pine was marked with the most delayed value in each of 54 s, 55 s. The maximum heat release rate ($HRR_{peak}$) was $156.87{\sim}235.1kW/m^2$, and the risk of early fire was highest in spruce. Total heat release of red pine was obtained in the highest value with $114.2MJ/m^2$. The mean effective heat of combustion of Japanese cedar was 19.1 MJ/kg and the highest among the samples. Fire risk of wood by FPI was orderly increased from lauan ($0.2468s{\cdot}m^2/kW$), red pine ($0.2339s{\cdot}m^2/kW$), spruce ($0.2308s{\cdot}m^2/kW$) to Japanese cedar ($0.2231s{\cdot}m^2/kW$). Fire risk of wood by FGI get increased from lauan ($0.5088kW/m^2{\cdot}s$), red pine ($0.5111kW/m^2{\cdot}s$), Japanese cedar ($2.8522kW/m^2{\cdot}s$) to spruce ($3.0662kW/m^2{\cdot}s$). Therefore, the risk of fire on the heat release characteristics of woods were found that spruce and Japanese cedar showed the high value compared with the other specimens.

Experimental Study on the Measurement of Fire Behavior and Heat Release Rate in Building Compartment Space - Focus on Full Scale Fire Test of the Bed Mattress - (건축물 구획공간에 따른 화재성상 및 열방출율 측정에 관한 실험적 연구 - 실물규모 침대 매트리스 화재시험 중심으로 -)

  • Seo, Bo-Youl;Jang, Woo-Bin;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.28-33
    • /
    • 2018
  • To measure the full scale fire test and heat release rate of bed mattresses according to the building compartment space, a fire test was performed using the Standard test method to determine the heat release rate of mattresses and mattress sets (KS F ISO 12949: 2011). Both test locations showed similar fire growth until approximately 3 minutes after burner ignition. After 3 minutes, the heat release rate in the test room was higher than the open calorimeter. For bed mattresses (SS), the maximum heat release rate in the open calorimeter was 735 kW and the maximum heat release rate in the test room was 992 kW. For bed mattresses (Q), the heat release rate in the test room increased more rapidly than the open calorimeter. The maximum heat release rate in the open calorimeter was 1,087 kW (346 s) and the maximum heat release rate in the test room was 2,127 kW (287 s). The difference between the maximum heat release rate and the measurement time according to the test location was confirmed.

Experimental Study on the Fire Performance of PC Slab by the Bearing Length (걸침길이에 따른 PC 슬래브의 화재성능에 관한 실험적 연구)

  • Park, Siyoung;Kang, Thomas H.K.;Lee, Ho-Wook;Gwak, Si-Young;Park, Jun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.14-22
    • /
    • 2022
  • In this study, a fire test was conducted to evaluate the fire performance of precast concrete (PC) slabs in an outdoor environment in response to the increase in fire incidents caused by the growth of warehouses. Prior to the field fire test, the tensile yield strength of the tendon at elevated temperatures was tested to analyze the mechanical properties. Also, by referring to previous studies, the thermal properties of tendon and the mechanical and thermal properties of concrete were investigated. A field fire test was conducted to analyze the structural and fire performance of two identical slabs with 50 and 150 mm bearing length. As the bearing length increased, deflection and horizontal displacement decreased. The fire test lasted for 200 minutes without the collapse of slabs, validating current codes. Based on the structural performance which maintained even with concrete spalling and rupture of some tendons, the bonded method is assumed to be practical in pre-tensioned PC slabs. The results of fire test are expected to be utilized in evaluating the fire performance of PC slabs in warehouses.

Experiences of Posttraumatic Growth in Firefighters with Repeated Traumatic Events (반복적 외상 사건을 겪은 소방공무원의 외상 후 성장 경험)

  • Ko, Youngshim;Ha, Yeongmi
    • Korean Journal of Occupational Health Nursing
    • /
    • v.30 no.3
    • /
    • pp.132-143
    • /
    • 2021
  • Purpose: The study aimed to explore experiences of the posttraumatic growth (PTG) in firefighters with repeated exposure to traumatic events. Methods: Participants were 11 firefighters from two fire departments, who had experienced more than one critical trauma events. Data were collected through personal interviews from August to October 2020 and analyzed by Colaizzi's phenomenological methods. Results: The PTG experiences were derived into four categories: 'growth in self-perception', 'rediscovery of the meaning of life', 'deep interpersonal relationships', and 'discovery of the meaning of work'. Conclusion: These findings could be used as basic information for developing PTG program for firefighters such as logo-therapy, semantic therapy, and self-disclosure intervention using expressive writing and speaking.

Study on the Improvement of a Special Fire Police Judicial Police System (소방특별사법경찰제도의 문제점에 따른 개선방안 연구)

  • Park, Hyeong-Jin;Kim, Jung-Rae;Kim, Jong-Buk;Cha, jin;Kwon, Hyun-Seok;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.77-86
    • /
    • 2018
  • In recent years, the high growth of the Korean society has led to the development of large and small incidents and accidents, while safety regulations, such as the firefighting sector, have been strengthened with the expectation of people desiring safety. This study surveyed the problems and improvement plan of the current operation centered on the fire service public officers in Gyeonggi-do and Gangwon. As a result of the main research, it is necessary to arrange and carry out excellent investigative manpower, such as lawyers and professional career veterans in the fire department, metropolitan city and provincial firefighting headquarters, and frontline fire departments. In particular, it was suggested that a special task force should be established and set up in the above agency, and the planning investigation and enforcement work should be solved through subdivision of the fire special enforcement officer tasks, and the judicial cases that are difficult to be handled by the local fire station. In future research, it will be necessary to study the field of fire - fighting specialists' needs for more specialized education and various disaster field experiences.

A Study on the Arson Characteristic by the Economic Variable (경제적변수에 따른 방화특성에 관한 연구)

  • Park, Nam-Kwun;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.14-19
    • /
    • 2011
  • This research was conducted with goals to reducing arson and finding its relationship with social phenomenons. Especially, unlike previous researches, focus has been on the economic indicators, and the effect of economic indicators on arson. As a result, we were able to find the relationship between economic indicators and arson. When growth rate and consumer index prices decrease, the economy stagnates and thus incidents of arson increases. In contrast, when growth rate increases and consumer index prices increase, the rate in which arson occurred decreased. Also, we have found that when personal debt rate increases, the numbers of arson incidents increased as well.