• Title/Summary/Keyword: Problem Statement

Search Result 515, Processing Time 0.024 seconds

PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION (하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석)

  • Cho Hye-Won;Kim Nan-Young;Kim Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

COMPARATIVE STUDIES OF RETENTIVE FORCES IN MAXILLARY OVERDENTURE BAR ATTACHMENTS (상악 임플랜트 Overdenture에서 Bar Attachment 설계에 따른 유지력 변화에 관한 연구)

  • Son Cha-Young;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.650-661
    • /
    • 2005
  • Statement of problem: It could be hypothesised that attachments, which provide more retention against vortical and horizontal dislodgement, will be associated with more favorable parameters of oral function. Purpose: This study was to provide data of initial retentive force and retention loss of different bar attachment systems recommended for use with maxillary implant overdentures. Material and method: 4 implants were placed in the anterior region of edentulous maxilla, five different systems of bar attachment were fabricated as follows: cantilevered Hader bar using clips (Type 1), Hader bar using clips without cantilever (Type 2), Hader bar using clip and ERA attachment orange male (Type 3), Hader bar using clip and ERA attachment white male (Type 4), and Bar using magnets (Type 5). Each samples were placed in the universal testing machine for determination of retentive forces(at initial and after every 200 cycles up to 1,000 cycles). Results and Conclusion 1. Attachment type 1 showed the biggest initial retentive force followed by type 3, type 2, type 4, and lastly type 5(P<0.001). 2. After 1,000 cycles of repeated removals of attachments, significant loss of retentive forces was taken place except for attachment type 5. 3. After 1,000 cycles of repeated removals, the loss of retentive force between type 1 and type 2, which used Hader bar and clip attachments. was greater in type 1 that had wider clip formation. And between type 3 and type 4, which used ERA attachments, the loss of retentive force was greater in type 4 that had white male attached (P<0.001). 4. After 1.000 cycles of repeated removals, attachment type 3 showed the biggest retentive force followed by type 2, type 4, type 1 and lastly type. 5. There was no significant difference between attachment type 3 and 4, and type 4 and 1(P<0.001).

PHOTOCATALYTIC ANTIEUNGAL ACTIVITY AGAINST CANDIDA ALBICANS BY $TiO_2$ COATED ACRYLIC RESIN DENTURE BASE

  • Yang Ji-Yeon;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.284-294
    • /
    • 2006
  • Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of the denture is equally important as treatment of the tissue. Cleansing and disinfection should be efficiently carried-out as the organisms can penetrate into the voids of the acrylic resin and grow in them, from which they can continue to infect and reinfect bearing tissues. Purpose. The purpose of this study was to evaluate the applicability of photocatalytic reaction to eliminate Candida albicans from acrylic resin denture base, and to investigate the anti-fungal effect with various UVA illumination time. Materials and Methods. The specimens were cured by the conventional method following the manufacturer's instruction using thermal polymerized denture base resin (Vertex RS: Dentimex, Netherlands). $TiO_2$ photocatalyst sol(LT), which is able to be coated at normal temperature, was made from the Ti-alkoxide progenitor. The XRD patterns, TEM images and nitrogen absorption ability of the $TiO_2$ photocatalyst sol(LT) were compared with the commercial $TiO_2$ photocatalyst P-25. The experimental specimens were coated with the mixture of the $TiO_2$ photocatalyst sol(LT) and binder material (silane) using dip-coater, and uncoated resin plates were used as the control group. Crystallinity of $TiO_2$ of the specimen was tested by the XRD. Size, shape and chemical compositions were also analyzed using the FE-SEM/ EDS. The angle and methylene blue degradation efsciency were measured for evaluating the photocatalytic activity of the $TiO_2$ film. Finally, the antifungal activity of the specimen was tested. Candida albicans KCTC 7629(1 ml, initial concentration $10^5$ cells/ ml) were applied to the experiment and control group specimens and subsequently two UVA light source with 10W, 353 nm peak emission were illuminated to the specimens from 15cm above. The extracted $2{\mu}l$ of sample was plated on nutrient agar plate ($Bacto^{TM}$ Brain Heart Infusion; BD, USA) with 10 minute intervals for 120 minute, respectively. It was incubated for 24 hours at $37^{\circ}C$ and the colony forming units (CFUs) were then counted. Results. Compared the characteristics of LT photocatalyst with commercial P-25 photocatalyst, LT were shown higher activity than P-25. The LT coated experimental specimen surface had anatase crystal form, less than 20 nm of particle size and wide specific surface area. To evaluate the photocatalytic activity of specimens, methylene blue degradation reaction were used and about 5% of degradation rate were measured after 2 hours. The average contact angle was less than $20^{\circ}$ indicating that the LT photocatalyst had hydrophilicity. In the antifungal activity test for Candida albicans, 0% survival rate were measured within 30 minute after irradiation of UVA light. Conclusion. From the results reported above, it is concluded that the UVA-LT photocatalytic reaction have an antifungal effect on the denture surface Candida albicans, and so that could be applicable to the clinical use as a cleaning method.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

EFFECT OF IMPLANT DESIGNS ON INSERTION TORQUE AND IMPLANT STABILITY QUOTIENT (ISQ) VALUE

  • Piao Chun-Mei;Heo Seong-Joo;Koak Jai-Young;Kim Seong-Kyun;Han Chong-Hyun;Fang Xian-Hao
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.325-332
    • /
    • 2006
  • Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant stability and osseiointegratation are considered highly desirable. Purpose. The purpose of this study was to evaluate the ISQ value and the insertion torque of the 3 different implant system, then to evaluate whether there was a correlation between ISQ value and insertion torque; and to determine whether implant design has an influence on either insertion torque or ISQ value. Material and method. The experiment was composed of 3 groups: depending on the implant fixture design. Group1 was Branemark type parallel implant in $3.75{\times}7mm$. Group2 was Oneplant type straight implant in $4.3{\times}8.5mm$. Group3 was Oneplant type tapered implant in $4.3{\times}8.5mm$. Depending on the density of the bone, 2 types of bone were used in this experiment. Type I bone represented for cortical bone, type II bone represented for cancellous bone. With the insertion of the implant in type I and type II bone, the insertion torque was measured, then the ISQ value was evaluated, and then the correlation between insertion torque and ISQ value was analyzed Result and conclusion. Within the limitations of this study, the following conclusions were drawn. 1. Within the 3 different implants, the insertion torque value and ISQ value were higher in type I bone, when compared with type II bone.(p<0.05) 2. In type I and type II bone, Oneplant type tapered implant has the highest value in insertion torque.(p<0.05) 3. In type I and type II bone, there was no difference in ISQ values among the 3 types of implant. (p>0.05) 4. Significant linear correlation was found in $Br{\aa}nemark$ type parallel implant: $3.75{\times}7mm$ in type II bone.

SURFACE CHARACTERISTICS OF ANODIC OXIDIZED TITANIUM ACCORDING TO THE PORE SIZE

  • Ha Heon-Seok;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.343-355
    • /
    • 2006
  • Statement of problem. The success of osseointegration can be enhanced with an implant that has improved surface characteristics. Anodic oxidation is one of the surface modifying method to achieve osseointegration. Voltage of anodic oxidation can change surface characteristics and cell activity Purpose. This study was performed to evaluate MG63 cell responses such as affinity, proliferation and to compare surface characteristics of anodic oxidized titanium in various voltage. Material and method. The disks for cell culture were fabricated from grade 3 commercially pure titanium,1 m in thickness and 12 mm in diameter. Surfaces of 4 different roughness were prepared. Group 1 had a machined surface, used as control. Group 2 was anodized under 220 V, group 3 was anodized under 300 V and group 4 was anodized under 320 V. The microtopography of specimens was observed by scanning electron microscope (JSM-840A, JEOL, Japan) and atomic force microscope(Autoprobe CP, Park Scientific Instrument, USA). The surface roughness was measured by confocal laser scanning microscope(Pascal, LSM5, Zeiss, Germany). The crystal structure of the titanium surface was analyzed with x-ray diffractometer(D8 advanced, Broker, Germany). MG63 osteoblast-like cells were cultured on these specimens. The cell morpholgy was observed by field emission electron microscope(Hitachi S-4700, Japan). The cell metabolic and proliferative activity was evaluated by MTT assay Results and conclusion. With in limitations of this in vitro study, the following conclusions were drawn. 1. In anodizing titanium surface, we could see pores which did not show in control group. In higher anodizing voltage, pore size was increased. 2. In anodizing titanium surface, we could see anatase. In higher anodizing voltage, thicker oxide layer increased crystallinity(anatase, anatase and rutile mixed). 3. MG63 cells showed more irregular, polarized and polygonal shape and developed more lamellipodi in anodizing group as voltage increased. 4. The activity of cells in MTT assay increased significantly in group 3 and 4 in comparison with group 1 and 2. However, there was no difference between group 3 and 4 at P<0.05. Proliferation of MG63 cells increased significantly in pore size($3-5.5{\mu}m$) of group 3 and 4 in comparison with in pore size($0.2-1{\mu}m$ ) of group 2.

AGAR-ALGINATE COMBINED IMPRESSION TECHNIQUE AND DIMENSIONAL CHANGE RESULTING FROM IDOPHOR DISINFECTION (아기-알지네이트 연합 인상체의 보관방법 및 idophor 침적소독에 의한 체적 변화에 관한 연구)

  • Oh Nam-Sik;Seo Joung-Min;Kim Sun-Hee;Youn Young-Ah;Shim Joon-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Statement of problem : Because dental impression can be a cross-infection source, disinfection, such as immersion disinfection is nessecary. However, the disinfection process may change the volume of the impression cast. Purpose : The purpose of this study is to find out the effects on dimensional change of different storage times and methods, of agar-alginate impression when immersed in a 5% idophor disinfectant. Material and Methods : An agar-alginate impression was made from a mandible model and then was disinfected and stored according the experimental conditions and a stone model was produced. Measurements were taken between reference points on the original mandible model and they were compared to measurements taken between reference points on the stone model. The study was divided into 4 groups. In group 1, the impression was stored in a 100% humidor for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours and 24 hours and stone models were made at each time. In group 2, the impression was immersed in 5% idophor disinfectant and then stored in a 100% humidor for the same length of times as group 1, and stone models were made at each time. In group 3, the impression was stored in extend-A-pourR, a special storage solution for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours, 24 hours 3 days, and 7 days and stone models were made at each time. In group 4, the impression was immersed in 5% idophor disinfectant and then stored in stored in extend-A-pourR, a special storage solution for the same length of times as group 3, and stone models were made at each time. 5 impressions and stone models were made at each time to make a total of 180. The Student-t test (P < .05) was used to do a statistical analysis of the measurements of the mandible model and stone models. The repeated-measure 2-way analysis of variance (P < .05) was used to do a statistical analysis of the difference in the 4 groups. Results : The percent liner dimensional change was from $0.25{\pm}0.03%$ (group 1, 30 minutes) to $0.34{\pm}0.06%$ (group 4, 7 days). No significant change was noticed between the 4 groups. Conclusion : According to the above study, in both methods, least dimensional change was recorded when the storage times were short and in both methods, immersion in 5% idophor disinfectant did not effect dimensional change in the agar-alginate impression.

SHADE PERCEPTION ABILITY AMONG DIFFERENT DENTAL PERSONNEL (치과 종사자간의 색조 식별 능력)

  • Kim Ja-Yeong;Lee Im-Gi;Yoon Tae-Ho;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.455-465
    • /
    • 2006
  • Statement of problem: Many factors influence shade determination in clinical practice and shade matching is highly affected by the viewing conditions. Purpose : This study investigated the differences in shade perception among distinct groups of dental personnel (10 prosthodontists, 10 general practitioners, 10 last-year dental students and 10 dental technicians) Material and method: Four groups of dental personnel were investigated. They were tested to eliminate color blindness. To compare shade selection ability, they were asked to match four test tabs of shades A3, B2, C2 and D4 (VITAPAN$^{(R)}$ Classical shade guide. The identification codes of the shade tabs were masked to prevent shade memory. ) against another full set of VITA$^{(R)}$ PAN$^{(R)}$ Classical shade guide under similar lighting conditions. Shade selections were randomly repeated five times every week and then the repeatability between dental personnel was evaluated. To compare value perception ability, they were asked to arrange randomly selected five test tabs (Bl, A2, D2, C3, A4) in descending order from the brightest to the darkest. To compare hue determination ability, they were asked to divide selected eight test tabs (n, A3, B2, B3, C2, C3, D2, D3) into four groups by manufacturer as follows : Group A-Reddish brown, Group B-Reddish yellow. Group C-Grey. Group D-Reddish grey. Results and conclusion : The obtained results were as follows : 1. For the value perception ability and hue determination ability. there was no significant difference among 4 groups: prosthodontists, general practitioners, dental students, dental technicians (P>.05). 2. For shade selection ability, the prosthodontists and dental technicians were significantly higher than dental students(P<.05). 3. The repeatability of selected shade in the dental technicians was significantly higher than that of general practitioners and dental students(P<.05). 4. The prosthodontists and dental technicians had significantly higher selection ability than dental students for shade B2 (P<.05).

RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS (유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Song Kie-Bum;Kim Sung-Rok;Park Kwang-Soo;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.

Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining (Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교)

  • Han, Sun-Deok;Kim, Won;Choi, Ji-Young;Oh, Nam-Sik;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Statement of problem: when using resin for class II restoration, micoleakage by instrumentation can be regarded as the primary negative characteristic. A review of the available literature suggests that using flowable resin as liner to decreased microleakage. Purpose: The aim of this study was to determine the influence of the nanofilled flowable resin lining on marginal microleakage after load cycling in class II composite restoration fillings using nanofiller resin. Material and methods: 24 extracted premolars were prepared with class II cavity. F group was restored the nanofilled resin with the nanofilled flowable resin as liner. NF group was restored the nanofilled resin only. After restoration, an experiment was performed on 2 groups using a 300N load at 104, 105 and 106 cycles. Prior to and before each load cycling, it was gauged length on total marginal microleakage, axial marginal microleakage and buccal, gingival, lingual marginal microleakage. Data were analyzed with the Mann-Whitney test & Kruskal-Wallis test. Results: There were statistically significant differences between 2 groups and between individual groups. (P <.05) The result showed less microleakage in teeth restored by the nanofilled resin, which was lined by the nanofilled flowable resin. Conclusion: There was significant reduction in microleakage when the nanofilled flowable resin lining was placed underneath the nanofilled resin in class II composite restoration fillings.