• 제목/요약/키워드: ILs

검색결과 279건 처리시간 0.031초

하부 구성품의 신뢰도 특성을 고려한 복합 시스템의 최적 예방정비 주기 산출 (Optimal Preventive Maintenance Period in Complex Systems in Considering Components Reliability Characteristic)

  • 이연호;이익도;이동우;손기홍
    • 대한산업공학회지
    • /
    • 제37권4호
    • /
    • pp.390-399
    • /
    • 2011
  • Generally the life-cycle cost of complex systems composed of several sub systems or equipments such as train, aircraft weapon systems is spent much more during operation and maintenance phase than development phase. The maintenance cost for maintaining the availability and extending the life span of systems comprise a large proportion of systems operation cost. The cycle of preventive maintenance affects operation and maintenance cost a lot. In this study we introduce a way minimizing life-cycle cost of systems by calculating more reliable preventive maintenance period than the results of previous study using systems reliability data considered the reliability and failure effect ratio of sub-systems or components. We can solve the preventive maintenance period problem known as NP-Hard as quick as possible by using modified genetic algorithm than using other models introduced in previous study.

태안비행장 GBAS Curved Approach 비행시험에 관한 연구 (A Study on GBAS Curved Approach Flight Test in Taean Airport)

  • 김우리얼;홍교영
    • 한국항행학회논문지
    • /
    • 제19권1호
    • /
    • pp.1-6
    • /
    • 2015
  • 전 세계적으로 급속하게 증가하는 항공교통량으로 인해 ICAO는 기존의 항행장비를 위성항법 기반으로 대체해 나가고 있으며, 이의 일환으로 기존의 ILS를 이용한 이착륙 서비스를 GBAS 로 대체할 계획을 수립 하였다. GBAS는 활주로까지 항공기를 유도하는 정밀 접근 서비스와 공항 주위의 정밀위치정보 서비스를 제공하는 위성항법 보강시스템을 이용하여 ILS와 달리 한 개의 시스템으로 활주로의 수에 관계없이 요구 성능을 제공할 수 있으며 curved approach가 가능하다는 장점을 보유하고 있다. 본 논문에서는 태안비행장 비행시험을 통한 ILS접근 절차와 GBAS curved approach절차를 비교하여 비행시간 단축 및 연료 감소효과를 분석하였으며 실제 비행시험을 통하여 이를 측정 확인 하였다.

Precious Metals Extraction Processing in Chloride Media by Using Ionic Liquids as Novel Extractant Systems

  • Kumar, Jyothi Rajesh;Choi, In-Hyeok;Lee, Jin-Young
    • Korean Chemical Engineering Research
    • /
    • 제55권4호
    • /
    • pp.503-509
    • /
    • 2017
  • The present experimental study proposed two ionic liquids (ILs) namely [Aliquat 336] [$HSO_4$] (prepared and characterized at our laboratory) and Cyphos 101 IL (supplied by Cytec Company) dissolved in two different diluents such as DCM (di-chloro-methane) and toluene applied for PMs extraction. The first IL [Aliquat 336] [$HSO_4$] prepared and confirmed the formation of final product by using FT-IR and TGA studies. The primary experiment in solvent extraction processing is kinetic effect; 0 to 30 time varied for PMs by using two ILs and confirmed the optimized extraction equilibrium time. This study was conducted for PMs (Pt, Rh and Cu) extraction and separation from each other by using proposed ILs. This is the primary study of the utilizing green solvents such as ILs as an extractant system for Pt, Rh and Cu extraction and possible separation.

무선센서네트워크에서 노드의 위치추정을 위한 반복최소자승법의 지역최소 문제점 및 이에 대한 해결책 (Local Minimum Problem of the ILS Method for Localizing the Nodes in the Wireless Sensor Network and the Clue)

  • 조성윤
    • 제어로봇시스템학회논문지
    • /
    • 제17권10호
    • /
    • pp.1059-1066
    • /
    • 2011
  • This paper makes a close inquiry into ill-conditioning that may be occurred in wireless localization of the sensor nodes based on network signals in the wireless sensor network and provides the clue for solving the problem. In order to estimate the location of a node based on the range information calculated using the signal propagation time, LS (Least Squares) method is usually used. The LS method estimates the solution that makes the squared estimation error minimal. When a nonlinear function is used for the wireless localization, ILS (Iterative Least Squares) method is used. The ILS method process the LS method iteratively after linearizing the nonlinear function at the initial nominal point. This method, however, has a problem that the final solution may converge into a LM (Local Minimum) instead of a GM (Global Minimum) according to the deployment of the fixed nodes and the initial nominal point. The conditions that cause the problem are explained and an adaptive method is presented to solve it, in this paper. It can be expected that the stable location solution can be provided in implementation of the wireless localization methods based on the results of this paper.

중복설계 및 예방정비를 고려한 수리가능 k-out-of-n 시스템 신뢰도 최적화 전략 (Optimal Reliability Strategy for k-out-of-n System Considering Redundancy and Maintenance)

  • 이연호;정광균;윤태동;권기상
    • 대한산업공학회지
    • /
    • 제40권1호
    • /
    • pp.118-127
    • /
    • 2014
  • The configuration such as series, parallel and k-out-of-n of a repairable system directly affects its reliability. The maintenance strategy can also affect the overall performance of the system. The objective of this work is to investigate the possible trade-off between the configuration of a repairable k-out-of-n system and its maintenance strategy. The redundancy is considered to be the design decision variables, whereas the preventive maintenance period is considered to be the maintenance decision variables. The optimization model is used to minimize the overall life cycle cost associated with the system, considering constraint on reliability. Finally, genetic algorithm is used to find the optimal values for the decision variables. The result is compared with optimal values for considering redundancy and maintenance respectively.

가상현실 기반의 무기체계 군수지원성 설계 검증 방안 : 사례연구 (A Case Study on Design Verification for Supportability of Weapon System Based on Virtual Reality)

  • 김희욱;이학표;이승용;강성욱;허길환
    • 한국군사과학기술학회지
    • /
    • 제19권1호
    • /
    • pp.76-83
    • /
    • 2016
  • State-of-the-art design S/W and other 3D systems are used for design and development of weapon system. It is possible to detect problems of design through 3D or VR(Virtual Reality) in advance, and then reduce the development cost by finding solutions before prototype production. Therefore, we can increase efficiency for supportability of weapon system. In this study, we first propose a design verification procedure. Then we verify design of weapon system, underwater guided weapon, as a case study. Finally, we suggest alternatives for underwater guided weapon under development with DMS(Digital Maintenance System) and ICIDO from the point of view of ILS(Integrated Logistics Support). Developed S/W, DMS, draws maintenance procedures for components. Commercial S/W, ICIDO, verifies cable maintainability.

스러스트 래버린스 실을 배면에 갖는 원심형 임펠러의 축력 해석 (Analysis of the Axial Thrust Force of a Centrifugal Impeller with a Thrust Labyrinth Seal at its Backside)

  • 박준혁;김태호
    • Tribology and Lubricants
    • /
    • 제37권1호
    • /
    • pp.31-40
    • /
    • 2021
  • This study describes the effects of a thrust labyrinth seal applied to the backside of a centrifugal impeller on the axial thrust force for high speed turbomachinery. The bulk flow model using Neumann's equation calculates the seal cavity pressures and leakage flow rate of the thrust labyrinth seal based on three configurations: teeth-on-rotor (TOR), teeth-on-stator (TOS), and interlocking labyrinth seal (ILS). Prediction results show that the ILS is superior to the TOR and TOS in terms of leakage flow rate. A mathematical model of a centrifugal impeller with a thrust labyrinth seal on its backside calculates the force components corresponding to the impeller inlet, shroud, impeller backside outer, backside seal, and backside inner pressures. A summation of the force components renders the total axial thrust force acting on the centrifugal impeller. The Newton-Raphson numerical scheme iteratively calculates the pressures and leakage flow rate through the impeller wall gap. The prediction results reveal that the leakage flow rate and total axial thrust force increase with rotor speed, and the ILS significantly decreases the leakage flow rate, whereas it slightly increases the axial thrust force when compared to TOR and TOS. Increasing the seal clearance causes an increase in the leakage flow rate and a slight decrease in the axial thrust force with the ILS.

미국 군수체계데이터(LPD) 국내 적용방안 연구 (A Study of Domestic Application of U.S. LPD(Logistics Product Data))

  • 김근영;김남수;조기형;이혁;박재현
    • 한국항공우주학회지
    • /
    • 제50권9호
    • /
    • pp.663-668
    • /
    • 2022
  • 미국은 2000년대 초반부터 무기체계의 전투준비태세를 유지하면서 수명주기비용을 줄이기 위해서 TLCSM를 적용하였다. TLCSM이 적용되면서 획득단계 중심의 ILS 개념에서 전체 수명주기 동안 수명주기비용을 관리하는 개념인 IPS로 전환하였다. 또한 ILS를 개발하기 위한 LSAR은 IPS을 개발하기 위한 LPD로 전환하였다. 본 연구에서는 한국의 LSAR과 미국의 LPD를 비교 및 분석하여 LPD의 한국 도입 시 필요한 정책을 제안하였다.

이온성 액체의 기술 동향 (Technology Trend in Ionic Liquids)

  • 이현주;이제승;안병성;김훈식
    • 공업화학
    • /
    • 제16권5호
    • /
    • pp.595-602
    • /
    • 2005
  • 이온성 액체는 $100^{\circ}C$ 이하에서 액체로 존재하는 이온성 염으로 낮은 휘발성, 비가연성, 높은 온도에서의 액체상 안정성, 유기물과 무기물에 대한 높은 용매화 능력, 높은 전기 전도성 등 독특한 화학적, 물리적, 전기적 특성을 갖고 있어 신 개념의 매체로 주목받고 있다. 특히, 이용 목적에 따라 양이온과 음이온을 다양하게 조합하여 그 특성을 변화시킬 수 있어서 디자이너 용매(designer solvent)라고도 불린다. 이온성 액체는 기존 화학산업을 비롯한 에너지, 재료, 전자 등 광범위한 산업분야에서 필수적으로 사용되는 휘발성 유기용매를 대체하여 환경유해물질의 배출을 원천적으로 방지하면서 반응선택성과 반응성을 향상시킬 수 있는 green media로 기대되고 있다. 본 총설에서는 이온성 액체의 구조, 특성, 응용분야와 연구동향에 대해 기술하였다.

방진마스크의 안면부 누설률에 관한 연구 (Inward Leakage Test for Particulate Filtering Respirators in Korea)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.