• Title/Summary/Keyword: Current Mismatch

Search Result 171, Processing Time 0.036 seconds

A Feed-forward Method for Reducing Current Mismatch in Charge Pumps (전하 펌프의 전류 부정합 감소를 위한 피드포워드 방식)

  • Lee, Jae-Hwan;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.63-67
    • /
    • 2009
  • Current mismatch in a charge pump causes degradation in spectral purity of the phase locked loops(PLLs), such as reference spurs. The current mismatch can be reduced by increasing the output resistance of the charge pump, as in a cascoded output stage. However as the supply voltage is lowered, it is hard to stack transistors. In this paper, a new method for reducing the current mismatch is proposed. The proposed method is based on a feed-forward compensation for the channel length modulation effect of the output stage. The new method has been demonstrated through simulations on typical $0.18{\mu}m$ CMOS circuits.

A Design of Charge Pump with Up/Down Current Mismatch Compensation for PHS Application (Up/Down Current Mismatch 보상 기능을 추가한 Charge Pump 회로의 설계)

  • Kim, Sang-Woo;Park, Joon-Sung;Ko, Dong-Hyun;Pu, Young-Gun;Lee, Kang-Yoon
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.472-473
    • /
    • 2008
  • This paper presents a charge pump used in frequency synthesizer for PHS application. The up/down current mismatch of charge pump has a critical effect on the phase noise and spur performance in frequency synthesizer. Therefore, the mismatch compensation scheme is proposed in this paper. And, the measurement results show that the mismatch can be reduced below 5 %.

  • PDF

Compensation of PV Module Current for Reduction of Mismatch Losses in PV Systems (태양광 시스템의 부정합 손실 저감을 위한 모듈 전류 보상 기법)

  • Ahn, Hee-Wook;Park, Gi-Yob
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.26-32
    • /
    • 2012
  • A current compensation method to reduce the mismatch loss in PV systems is proposed as a way to increase the power generation efficiency. A dc-dc converter is used to supply currents to irregular modules in a PV string and is powered from the string output. The converter's voltage conversion ratio is adjusted so that all the modules in the string are operated at the maximum power point. The power rating and size of the converter can be reduced since only the current difference between the regular and irregular module may be supplied. The compensated string shows very little voltage mismatch compared to other regular strings. The validity of the proposed method is verified through a simulation and experiments in a prototype PV system.

Analysis of Module Mismatch Loss in Solar PV String and Feasibility Study for Improvement Method (태양광 PV 스트링에서의 모듈 부정합 손실의 분석 및 개선 기법 타당성 연구)

  • Ahn, Hee-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • In this paper, the power loss due to PV module mismatch in PV string is analyzed and a mismatch compensation method is proposed to improve the efficiency of PV system. The analysis of mismatch loss using PV model simulation reveals that the mismatch module may decrease the total efficiency because the MPPT function of power conditioner make the PV system operate at the local maximum point. The mismatch loss can be severe if the maximum power point current of mismatch module is less than that of string. The proposed compensation method which is simply implemented with a buck type converter shows the possibility to remove the mismatch loss. The effectiveness of the analysis and compensation method is verified by a prototype experiment.

A Dual-compensated Charge Pump for Reducing the Reference Spurs of a Phase Locked Loop (위상 고정 루프의 기준 스퍼를 감소시키기 위한 이중 보상 방식 전하 펌프)

  • Lee, Dong-Keon;Lee, Jeong-Kwang;Jeong, Hang-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.465-470
    • /
    • 2010
  • The charge pump in a phase-locked loop is a key block in determining reference spurs of the VCO output signal. To reduce reference spurs, the current mismatch in the charge pump must be minimized. This paper presents a dual compensation method to reduce the current mismatch. The proposed charge pump and PLL were realized in a $0.18{\mu}m$ CMOS process. Measured current matching characteristics were achieved with less than 1.4% difference and with the current variation of 3.8% in the pump current over the charge pump output voltage range of 0.35-1.35V at 1.8V. The reference spur of the PLL based on the proposed charge pump was measured to be -71dBc.

Diagnosis Method of PV Module Mismatch using Voltage and Current Waveforms (태양광 모듈의 전압 및 전류 파형을 이용한 부정합 진단 기법)

  • Ahn, Hee-Wook;Park, Gi-Yob
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.17-22
    • /
    • 2011
  • Techniques for mismatch loss minimization to increase the PV system efficiency are under development recently. In this paper, a method to make diagnosis of PV module mismatch is presented, which uses a concept of operating point factor. The method is based on the fact that the ratio of the incremental conductance of a PV module to instantaneous conductance is 1 when the module is operating at its maximum power point. The variations of module voltage and current are taking place by the maximum power point tracker in the power conditioning units of PV system. The effectiveness of the method is verified through an application to a real PV system.

Method for PV Module Mismatch Compensation to Reduce Parallel Mismatch in Solar PV Array (태양광 PV 어레이에서 병렬 부정합을 저감시키는 모듈 부정합 보상기법)

  • Park, Gi-Yob;Ahn, Hee-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.170-171
    • /
    • 2010
  • The power loss due to PV module mismatch in PV array system is analyzed and a mismatch compensation method is proposed. A dc-dc converter is used to compensate for series mismatch caused by a low current module in a string. The converter is controlled to maximize the array power output. The proposed compensation method was verified by PSpice simulation.

  • PDF

A Design of an Automatic Current Correcting Charge-Pump using Replica Charge Pump with Current Mismatch Detection (부정합 감지 복제 전하 펌프를 이용한 자동 전류 보상 전하 펌프의 설계)

  • Kim, Seong-Geun;Kim, Young-Shin;Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.94-99
    • /
    • 2010
  • This paper presents a charge pump architecture for correcting the current mismatch due to the PVT variation. In general, the current mismatch of the charge pump should be minimized to improve the phase noise and spur performance of the PLL. In order to correct the current mismatch of the charge pump, the current difference is detected by the replica charge pump and fed back into the main charge pump. This scheme is very simple and guarantees the high accuracy compared with the prior works. Also, it shows a good dynamic performance because the mismatch is corrected continuously. It is implemented in 0.13um CMOS process and the die area is $100{\mu}m\;{\times}\;160{\mu}m$. The voltage swing is from 0.2V to 1V at supply voltage of 1.2V. The charging and discharging currents are $100{\mu}A$, respectively and the current mismatch due to the PVT variation is less than 1%.

A Charge Pump Circuit in a Phase Locked Loop for a CMOS X-Ray Detector (CMOS X-Ray 검출기를 위한 위상 고정 루프의 전하 펌프 회로)

  • Hwang, Jun-Sub;Lee, Yong-Man;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.359-369
    • /
    • 2020
  • In this paper, we proposed a charge pump (CP) circuit that has a wide operating range while reducing the current mismatch for the PLL that generates the main clock of the CMOS X-Ray detector. The operating range and current mismatch of the CP circuit are determined by the characteristics of the current source circuit for the CP circuit. The proposed CP circuit is implemented with a wide operating current mirror bias circuit to secure a wide operating range and a cascode structure with a large output resistance to reduce current mismatch. The proposed wide operating range cascode CP circuit was fabricated as a chip using a 350nm CMOS process, and current matching characteristics were measured using a source measurement unit. At this time, the power supply voltage was 3.3 V and the CP circuit current ICP = 100 ㎂. The operating range of the proposed CP circuit is △VO_Swing=2.7V, and the maximum current mismatch is 5.15 % and the maximum current deviation is 2.64 %. The proposed CP circuit has low current mismatch characteristics and can cope with a wide frequency range, so it can be applied to systems requiring various clock speed.

Characteristics variation of PV module by damaged bypass diodes

  • Sin, U-Gyun;Jeong, Tae-Hui;Go, Seok-Hwan;Gang, Gi-Hwan;Jang, Hyo-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.424.2-424.2
    • /
    • 2016
  • Solar cell converts light energy to electric energy. But a solar cell generates low power, PV module is fabricated by connected in series with dozens of solar cell. Owing to solar cell connected in series, power of PV module is influenced by shading or mismatch power of solar cells. To prevent power loss of PV module by shading or mismatch current, Bypass diodes are installed in PV module. Bypass diode operating reverse voltage by shading or mismatch power of solar cells bypass mismatch current. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we confirm characteristics variation of PV module with damaged bypass diode. As a result, power of PV module with damaged bypass diode is reduced and Temperature of that is increased.

  • PDF