• Title/Summary/Keyword: Breakdown Structure

Search Result 685, Processing Time 0.027 seconds

Life Cycle Cost Breakdown Structure Development of Buildings through Delphi Analysis

  • Jeong, Jae-Hyuk;Shin, Han-Woo;Ryu, Han-Guk;Kim, Gwang-Hee;Kim, Tae-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.5
    • /
    • pp.528-538
    • /
    • 2012
  • With domestic construction projects becoming bigger, more specialized and more advanced, the construction industry is striving to improve quality and quantity, and is diversifying functions and shapes. Nevertheless, the process of a construction project causes problems when we estimate construction price, because the cost breakdown structures are different in each step. The primary aim of this study was to estimate building life cycle cost using the Delphi method. The cost breakdown structure for life cycle cost was classified into planning, design, construction, maintenance and waste disposal, and each detailed classification was determined by estimating life cycle cost. Moreover, the developed cost breakdown structure is verified by consulting with experts to secure objectivity and validity.

Improving The Breakdown Characteristics of AlGaN/GaN HEMT by Optimizing The Gate Field Plate Structure (게이트 필드플레이트 구조 최적화를 통한 AlGaN/GaN HEMT 의 항복전압 특성 향상)

  • Son, Sung-Hun;Kim, Tae-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.5
    • /
    • pp.1-5
    • /
    • 2011
  • In this paper, we optimize the gate field plate structure to improve breakdown characteristics of AlGaN/GaN HEMT by two-dimensional device simulator. We have simulated using three parameters such as field-plate length, types of insulator, and insulator thickness and thereby we checked change of the electric field distribution and breakdown voltage characteristics. As optimizing field-plate structure, electric fields concentrated near the gate edge and field-plate edge are effectively dispersed. Therefore, avalanche effect is decresed, so breakdown voltage characteristic is increased. As a result breakdown characteristics of optimized gate field-plate structure are increased by about 300% compared to those of the standard structure.

PBS Construction by Using DSM (DSM을 이용한 PBS 구출)

  • Kim, Chan-Mook;Park, Young-Won
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • This paper discusses WBS (Work Breakdown Structure) that is known for technique of basic project management. The WBS use in domestic industries often exhibit errors in Its structure. The most common serious error is space-oriented breakdown structure of PBS (Product Breakdown Structure) that becomes the core element of the WBS. This paper proposes a method to correct the problem of space-oriented breakdown structure constructed in domestic railroad industry. DSM method was adopted to construct PBS containing function-oriented structure. The proposed process and method will contribute to minimize time that take to construct an accurate and useful PBS.

Improvement of Design Performance for the Minimization of Public Grievances Based on a Construction Public Grievance Breakdown Structure (건설공사 민원 최소화를 위한 민원분류체계 기반 설계성능향상)

  • Moon, Sungwoo;Jo, Hwani
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.1
    • /
    • pp.12-20
    • /
    • 2018
  • Construction projects are often large in magnitude and high in construction amount. Therefore, construction activities have great impacts on business economics and social lives in the surrounding regional area. The residents can have public grievances if they are badly affected by the construction activities. Project owners should try to minimize adverse impacts in planning and design as well as in construction. The objective of this paper is to establish a public grievance breakdown structure and apply this breakdown structure to improving design functions in an effort to minimize public grievances. This research has been done in three steps of 1) analyzing the characteristics of public grievances in construction projects; 2) developing a public grievance breakdown structure; and 3) based on the public grievance breakdown structure, generating design alternatives that can improve the preparedness against public grievances. A case study has been done to demonstrate the applicability of the public grievance breakdown structure in generating design alternatives to minimize public grievances.

Development of Semantic Risk Breakdown Structure to Support Risk Identification for Bridge Projects

  • Isah, Muritala Adebayo;Jeon, Byung-Ju;Yang, Liu;Kim, Byung-Soo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.245-252
    • /
    • 2022
  • Risk identification for bridge projects is a knowledge-based and labor-intensive task involving several procedures and stakeholders. Presently, risk information of bridge projects is unstructured and stored in different sources and formats, hindering knowledge sharing, reuse, and automation of the risk identification process. Consequently, there is a need to develop structured and formalized risk information for bridge projects to aid effective risk identification and automation of the risk management processes to ensure project success. This study proposes a semantic risk breakdown structure (SRBS) to support risk identification for bridge projects. SRBS is a searchable hierarchical risk breakdown structure (RBS) developed with python programming language based on a semantic modeling approach. The proposed SRBS for risk identification of bridge projects consists of a 4-level tree structure with 11 categories of risks and 116 potential risks associated with bridge projects. The contributions of this paper are threefold. Firstly, this study fills the gap in knowledge by presenting a formalized risk breakdown structure that could enhance the risk identification of bridge projects. Secondly, the proposed SRBS can assist in the creation of a risk database to support the automation of the risk identification process for bridge projects to reduce manual efforts. Lastly, the proposed SRBS can be used as a risk ontology that could aid the development of an artificial intelligence-based integrated risk management system for construction projects.

  • PDF

The Calculation Method of the Breakdown Voltage for the Drain Region with the Spherical Structure in High Voltage Analog CMOS (Spherical 구조를 갖는 고전압용 Analog CMOS의 Drain 역방향 항복전압의 계산 방법)

  • Lee, Un Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1255-1259
    • /
    • 2013
  • A calculation method of the breakdown voltage for the Drain region with the spherical structure in high voltage analog CMOS is proposed. The Drain depletion region is divided into many sub-regions and the doping concentration of each sub-region is assumed to be constant. The field in each sub-region is calculated by the integration of the net charge and the breakdown voltage is calculated using the ionization integral method. The breakdown voltage calculated using the proposed method shows the maximum relative error of 3.3% compared with the result of the 2-dimensional device simulation using BANDIS.

Numerical Analysis of a SOI LDMOS with a Recessed Source for Low ON Resistance (ON 저항이 작은 Recessed Source 구조 SOI LDMOS의 수치해석)

  • Yang, Hoe-Yun;Kim, Seong-Ryong;Choe, Yeon-Ik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.605-610
    • /
    • 1999
  • An SOI(Silicon-On-Insulator) LD(Lateral Double-diffused)MOS with a recessed source structure is proposed to improve the on-resistance and the breakdown voltage. The recessed source structure can decrease the on-resistance by reducing the path of electron current, also increase the breakdown voltage by extending the effective length of gate field plate. Simulation results by TSUPREM4 and MEDICI have shown that the on-resistance of the LDMOS with a recessed source was 26% lower than conventional LDMOS. The breakdown voltage of proposed device was found to be 45V while that of conventional device was 36.5 V. At the same breakdown voltage of 36.5V, the on-resistance of the LDMOS with a recessed source was 41% lower than that of conventional structure.

  • PDF

The Calculation Method of the Breakdown Voltage for the Drain Region with the Cylindrical Structure in LDMOS (Cylindrical 구조를 갖는 LDMOS의 Drain 역방향 항복전압의 계산 방법)

  • Lee, Un Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1872-1876
    • /
    • 2012
  • A calculation method of the breakdown voltage for the drain region with the cylindrical structure in LDMOS is proposed. The depletion region of the drain is divided into many smaller regions and the doping concentration of each split region is assumed to be uniformly distributed. The field and potential in each split region is calculated by the integration of the Poisson equation and the ionization integral method is used to compute the breakdown voltage. The breakdown voltage resulted from the proposed method shows the maximum relative error of 2.2% compared with the result of the 2-dimensional device simulation using BANDIS.

A study on the breakdown characteristics of power p-n junction device using field limiting ring and side insulator wall (전계제한테와 측면 유리 절연막 사용한 전력용 p-n 접합 소자의 항복 특성 연구)

  • 허창수;추은상
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.386-392
    • /
    • 1996
  • Zinc-Borosilicate is used as a side insulator wall to make high breakdown voltage with one Field Limiting Ring in a power p-n junction device in simulation. It is known that surface charge density can be yield at the interface of Zinc-Borosilicate glass / silicon system. When the glass is used as a side insulator wall, surface charge varied potential distribution and breakdown voltage is improved 1090 V under the same structure.The breakdown voltage under varying the surface charge density has a limit value. When the epitaxial thickness is varied, the position of FLR doesn't influence to the breakdown characteristic not only under non punch-through structure but also under punch-through structure. (author). 7 refs., 12 figs., 2 tabs.

  • PDF

A Study on the Development of Optimal Alternative Selection Model to Renew Building Equipments System (건축설비시설의 갱신을 위한 최적 대체안 선정모델 개발에 관한 연구)

  • 윤동원;이정재;정광섭;한화택;정순성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.950-961
    • /
    • 2000
  • The objective of this study is to develop optimal alternative selection model for renewing building equipments system. Cost Breakdown Structure of LCC in HVAC systems are deduced from resonable data and factors. As for Cost Breakdown Structure of LCC in HVAC system, pertinent level, title, CBS number, and block number are determined efficiently. Especially, in addition to current cost factor, it is possible to make Cost Breakdown Structure using present worth method more clear. A model of POWER LCC ver 1.0 used to analyze primary cooling system, heating system, and air conditioning system are POWER LCC ver 1.0_/sub SYSTEM/ : C1+ C2- C3+ C4+ C5+ C6+ C7±C8+ C9- C10/sub -1/+ C10/sub -2/+ C10/sub -3/, and is implemented with consideration of Cost Breakdown Structure and their summation using present-worth method. It is programmed with one of scientific languages, MATLAB 5.3.

  • PDF