• 제목/요약/키워드: 공공 건물

검색결과 255건 처리시간 0.023초

열원장비의 적정용량산정을 위한 장비가동현황 및 할증률 분석 - 공공업무시설 - (The analysis on the operation condition and premium proportion for estimating the appropriate capacity of Cooling Equipment - Public office-)

  • 신무경;박성훈;박은하;장종운;이지원;김세환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.506-511
    • /
    • 2006
  • To today with the acceleration due to the preference actual condition of high-class energy national income level it is together improving. It follows hereupon and it is convenient and the neat heat source is increasing a tendency where it is. It investigates the government offices building in commerce portion from the research which it sees and from the draft it analyzes a coat dosage. And comparison it analyzes the movable present condition of thread use dosage and the freezer. It presents the improvement direction against enemy conditions heat source equipment selecting. Also, currently it produces the dosage of heat source equipment and application it tries. The result, the various safety rate and the premium rate which it uses universally are considered above thread using. The reappraisal for enemy conditions heat source equipment selecting which it follows hereupon is necessary.

  • PDF

2025년 의무화 로드맵에 따른 공공시설 제로에너지건축물 인증제도 시장 수용성 (Market Acceptability of the ZEB Certification System for Public Buildings According to the 2025 Roadmap)

  • 이승민;김진호;신광수;김의종
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.557-566
    • /
    • 2018
  • The ZEB certification system has come into effect since 2018 according to the ZEB road map. From 2020, the public buildings with the total floor area smaller than $3000m^2$ are the target of the certification, and it will be extended to the buildings with up to $5000m^2$ floor area in 2025. However, current mandatory regulations for public office buildings seem already to meet the ZEB certification system planned for 2025. In this work, two buildings belong to $3,000{\sim}5,000m^2$ in total floor area were selected to analyze the possibility of meeting the ZEB certification only by following current obligation regulations. Results showed that the test buildings satisfied the minimum building energy efficiency and energy self-sufficiency rates for the ZEB certification when the mandatory insulation and installation ratio of renewable energy are applied. This can be useful for revising the road map or extending the target buildings of the ZEB certification.

골조 외부에 부착한 강재댐퍼의 성능 평가 (Capacity Evaluation of Steel Damper Attached to Outside of Frame)

  • 이현호
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.382-388
    • /
    • 2017
  • 본 연구에서는 공공건물에 보강이 가능하도록 건물 외부에 록킹 월을 설치하고 이를 본 구조에 강재댐퍼로 연결하는 외부 보강 내진공법에 대한 기초 연구를 시행하였다. 2개의 실험체를 제작하였으며, 댐퍼 비보강 실험체는 기존 결과를 활용하였다. 포락선, 강도, 강성저하 및 에너지 소산능력을 평가한 결과, 플레이트 댐퍼를 외부 보강한 RW_P 실험체의 강도 증진이 우수한 것으로 평가되었다. 또한 S형 댐퍼를 외부 부착한 RW_S 실험체는 최대하중 이후에 완만한 포락곡선을 보여 댐퍼가 하중을 적절히 소산하는 것을 확인할 수 있었다.

공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석 (Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings)

  • 이한솔;김서훈;김종훈;김준태;장철용
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향 (A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea)

  • 이아영
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

민방위 대피시설 계획 및 설계 방안에 관한 연구 2 - 미국의 대피시설 계획 및 설계를 중심으로 - (A Study on the Planning of Civil Defense Shelter and Design 2 - Focused on Planning and Design of Defense Shelter the U.S. -)

  • Park, Namkwun;Kwon, Taeil;Kim, Twehwan
    • 한국재난정보학회 논문집
    • /
    • 제10권3호
    • /
    • pp.442-451
    • /
    • 2014
  • 현재 국내에 2만 여개의 대피시설이 지정되어 운영되고 있다. 그러나 북한의 화생방공격 혹은 화생방테러로부터 방호가 가능한 시설은 극소수에 불과하다. 또한 공공용 대피시설은 단순 방공호 수준의 성능만을 보유하고 있으며, 화생방공격에 대한 기준 확립이 시급하다. 이에 본 연구는 미국의 화생방 대피시설 중 SIP(건물 내 대피시설)를 중심으로 개념과 기준등의 현황분석을 통하여, 한국형 대피시설의 계획 및 구축 방안을 도출하고자 하였다.

학교시설 현황분석을 통한 에너지절약설계 개선방향 연구 (A Study on Design for Energy-saving Based on Analysis of Current Situation in School Facilities)

  • 맹준호;김성중;이승민;고현수
    • 교육녹색환경연구
    • /
    • 제17권3호
    • /
    • pp.1-8
    • /
    • 2018
  • 기후변화에 따른 지구 생태계의 변화와 에너지 및 자원고갈 등 전 지구적 대응노력이 절실한 상황에서 정부에서는 탈원전 정책 등 적극적인 정책을 수립하여 시행하고 있다. 특히 공공건물 중 적지 않은 비중을 차지하고 있는 학교시설은 학생수가 감소하는 반면 학교수가 증가하고 있으며 에너지사용량 또한 지속적으로 증가하고 있다. 본 연구에서는 학교시설의 설계현황을 분석하여 에너지절약설계의 개선방향을 제시하고자 하였다.

공간정보 속성에 따른 토지보상액 결정에 관한 연구 -공공주택지구 보상사례를 중심으로- (A Study on Compensation of Land according to the Spatial Properties -In case Compensation of Public Housing District-)

  • 문재혁;이명훈
    • 한국콘텐츠학회논문지
    • /
    • 제16권11호
    • /
    • pp.188-198
    • /
    • 2016
  • 주거복지 증진을 위해 필요한 택지공급을 위해서는 많은 토지를 취득해야 한다. 토지는 다양한 개발압력과 토지이용규제로 지가 결정에 대한 이견이 크며, 이러한 견해의 차는 공익사업 시행에 있어 갈등의 단초가 되고 있다. 지가 결정에 대한 객관적 연구를 통해 견해의 차이를 좁히는 것은 갈등 해결의 실마리를 제공하는 일이 될 것이다. 본 연구는 공익사업의 하나인 공공주택지구를 사례지역으로 선정하고, 보상단가를 종속변수로, 선행연구 및 전문가 집중인터뷰를 통해 선정된 변수를 독립변수로 하여, 헤도닉모형을 적용하여 지가에 영향을 주는 요인 및 그 정도를 분석하였다. 용도지역 및 이용상황을 기준으로 구분한 그룹별 분석결과 영향요인의 유의성 여부에서는 건물부지여부가, 영향력의 크기에서는 접근성측면과 공법상 제한측면이 그룹별로 상이한 결과가 도출되어, 합리적인 결과로 해석된다. 또한 선행연구에서 제시되지 않은 건물부지 여부를 변수로 추가 선정한 것과 도로접면 변수에 대한 비율척도 적용으로 보상액 영향 분석에 있어서 설명력이 높아졌다.

공공건축물의 그린리모델링 수준별 LCC (Life Cycle Cost) 분석을 통한 경제성 비교 (The Economic Comparision through LCC Analysis on each Graded Alternatives for Green Remodeling of Public Building)

  • 김재문;이정혁;이두환
    • 한국건설관리학회논문집
    • /
    • 제19권2호
    • /
    • pp.38-49
    • /
    • 2018
  • 파리협약 비준 이후 온실감축에 대한 중요성 및 국가 의무가 커짐에 따라 정부에서는 건축산업의 온실가스 감축을 위한 정책을 지속적으로 강화해 나가고 있으며, 특히 노후건축물에 대한 에너지 성능개선의 필요성을 강조하고 있다. 2014년 이후 정부에서는 공공 노후건축물 그린리모델링 사업의 시공비 지원 등으로 시범사업을 운영 중에 있으며 이를 통해 그린리모델링의 모범사례를 개발하여 민간에 그린리모델링을 활성 시키고자 한다. 본 연구에서는 공공 노후건축물의 그린리모델링을 통한 수준별 경제성을 분석하였으며, 해당건물의 대안을 계획하기 위해 건물 육안조사 및 장비측정을 수행하였다. 개선안은 대안을 종합한 그린리모델링 계획안으로 수준별 5개의 개선안을 개발하여 각 안에 대한 경제성을 분석하였다. 분석방법은 ECO2를 통한 1차 에너지소요량 산정 및 LCC 분석을 진행하였으며, LCC 측면에서는 개선 3, 4안(중간수준 안)이 가장 우수한 것으로 분석되었으며, 다음으로 최대비용안, 최소 비용 안 순으로 결과가 도출되었다. 이 결과로 향후 진행될 그린리모델링 성능계획 및 경제성 분석 시 기초자료로서 활용이 가능 할 것으로 예상된다.

교육시설의 건축물에너지효율등급 사례분석을 통한 에너지자립률 평가 (Evaluation of Energy Self-Sufficiency Rate through Case Analysis of Building Energy Efficiency Rating in Educational Facilities)

  • 이현승;김지현;이승민;맹준호;신우철
    • 교육녹색환경연구
    • /
    • 제18권4호
    • /
    • pp.58-65
    • /
    • 2019
  • 교육시설은 '공공기관 에너지이용 합리화 추진에 관한 규정'에 따라 2014년부터 '건축물에너지효율 1등급 이상'의 의무대상건축물로 지정되었으며, 동 규정에서 정의하는 공공기관 건축물에 해당되어, 2008년 9월 신·재생에너지 의무대상 건축물로 포함되었다. 또한 2019년 4월 녹색건축물 조성 지원법이 개정됨에 따라, 2020년부터 ZEB인증의 의무대상 건축물로 확정되었다. 따라서 본 연구에서는 2015년 2월부터 2019년 5월까지 "건축물에너지효율등급" 본인증을 획득한 316개의 교육시설을 대상으로 "건물에너지효율등급" 및 "신·재생에너지시스템"설치 현황을 파악하고, 에너지 소요량 및 신·재생에너지 생산량을 기준으로 에너지자립률을 분석하였다. 316개 본인증 교육시설의 "건축물에너지효율등급"에 따른 ZEB 인증등급을 추정하면 1+++ 등급 12개 시설의 경우 1곳을 제외하고 모두 ZEB 5등급 이상으로 나타났으며, 239개의 1++ 등급 시설에서 11%에 해당하는 28곳이 ZEB 5등급 수준에 도달하였다. 따라서 현 수준에서 일반 교육시설의 ZEB 인증은 무리가 있으며, 건물에너지효율 1+++등급 상향과 신·재생에너지시스템 투자가 선행되어야 할 것으로 판단된다.