Abstract
In this study, a basic study was carried out on the external strengthening method of public buildings. A steel damper is installed outside the specimen with a rocking wall and connected to the frame. Two specimens were fabricated, and the non-reinforced specimens utilized the existing results. As a result of evaluating the envelope curve, strength, stiffness and energy dissipation capacity, it was evaluated that the strength enhancement of the RW_P specimen externally reinforced plate damper was evaluated to be excellent. In addition, RW_S specimens with external S type damper shows a gentle envelop curve after maximum load, and it can be confirmed that the damper properly dissipates the seismic energy.
Keywords
External strengthening; Steel damper; Rocking wall; Energy dissipation capacity;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lee, H.H., Kim, J.H., Rho, K.G. (2012). Strengthening effectsof rc column using fiber reinforced polymer, Journal of theKorea Concrete Institute, 24(4), 473-480 [in Korean].   DOI
2 Lee, H.H. (2014). "Behavior of metallic damper in externalstrengthening," Proceeding of the Korea Institute for StructuralMaintenance and Inspection, 8(2), 678-679 [in Korean].
3 Lee, H.H. (2015a). "External strengthening evaluation of metallicdamper by strut shape," Proceeding of the Korea ConcreteInstitute, 27(1), 77-78 [in Korean].
4 Lee, H.H. (2015b). Capacity development of existing frame by aramid sheet and energy dissipation device, Journal of the Korea Institute for Structural Maintenance and Inspection, 19(5), 112-119 [in Korean].   DOI
5 Marriott, D., Pampanin S., Bull, D., Palermo, A. (2008). Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutions, Bulletin of the New Zealand Society of Earthquake Engineering, 41(2), 90-103.
6 Japan Society of Seismic Isolation. (2005). Design and ConstructionManual of Passive Seismic Control Structures, Japan Societyof Seismic Isolation [in Japanese].
7 Wada, A., Qu, Z., Motoyui, S., Sakata, H. (2011). Seismic retrofit of existing SRC frames using rocking walls and steel dampers, Frontiers of Architecture and Civil Engineering in China, 5(3), 259-266.   DOI