DOI QR코드

DOI QR Code

Capacity Evaluation of Steel Damper Attached to Outside of Frame

골조 외부에 부착한 강재댐퍼의 성능 평가

  • Lee, Hyun-Ho (Department of Architecture & Fire Service Administration, Dongyang University)
  • 이현호 (동양대학교 건축소방행정학과)
  • Received : 2017.09.03
  • Accepted : 2017.10.13
  • Published : 2017.12.30

Abstract

In this study, a basic study was carried out on the external strengthening method of public buildings. A steel damper is installed outside the specimen with a rocking wall and connected to the frame. Two specimens were fabricated, and the non-reinforced specimens utilized the existing results. As a result of evaluating the envelope curve, strength, stiffness and energy dissipation capacity, it was evaluated that the strength enhancement of the RW_P specimen externally reinforced plate damper was evaluated to be excellent. In addition, RW_S specimens with external S type damper shows a gentle envelop curve after maximum load, and it can be confirmed that the damper properly dissipates the seismic energy.

본 연구에서는 공공건물에 보강이 가능하도록 건물 외부에 록킹 월을 설치하고 이를 본 구조에 강재댐퍼로 연결하는 외부 보강 내진공법에 대한 기초 연구를 시행하였다. 2개의 실험체를 제작하였으며, 댐퍼 비보강 실험체는 기존 결과를 활용하였다. 포락선, 강도, 강성저하 및 에너지 소산능력을 평가한 결과, 플레이트 댐퍼를 외부 보강한 RW_P 실험체의 강도 증진이 우수한 것으로 평가되었다. 또한 S형 댐퍼를 외부 부착한 RW_S 실험체는 최대하중 이후에 완만한 포락곡선을 보여 댐퍼가 하중을 적절히 소산하는 것을 확인할 수 있었다.

Keywords

References

  1. Japan Society of Seismic Isolation. (2005). Design and ConstructionManual of Passive Seismic Control Structures, Japan Societyof Seismic Isolation [in Japanese].
  2. Lee, H.H., Kim, J.H., Rho, K.G. (2012). Strengthening effectsof rc column using fiber reinforced polymer, Journal of theKorea Concrete Institute, 24(4), 473-480 [in Korean]. https://doi.org/10.4334/JKCI.2012.24.4.473
  3. Lee, H.H. (2014). "Behavior of metallic damper in externalstrengthening," Proceeding of the Korea Institute for StructuralMaintenance and Inspection, 8(2), 678-679 [in Korean].
  4. Lee, H.H. (2015a). "External strengthening evaluation of metallicdamper by strut shape," Proceeding of the Korea ConcreteInstitute, 27(1), 77-78 [in Korean].
  5. Lee, H.H. (2015b). Capacity development of existing frame by aramid sheet and energy dissipation device, Journal of the Korea Institute for Structural Maintenance and Inspection, 19(5), 112-119 [in Korean]. https://doi.org/10.11112/jksmi.2015.19.5.112
  6. Marriott, D., Pampanin S., Bull, D., Palermo, A. (2008). Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutions, Bulletin of the New Zealand Society of Earthquake Engineering, 41(2), 90-103.
  7. Wada, A., Qu, Z., Motoyui, S., Sakata, H. (2011). Seismic retrofit of existing SRC frames using rocking walls and steel dampers, Frontiers of Architecture and Civil Engineering in China, 5(3), 259-266. https://doi.org/10.1007/s11709-011-0114-x