• 제목/요약/키워드: scintillation detector

검색결과 129건 처리시간 0.019초

Towards a better understanding of detection properties of different types of plastic scintillator crystals using physical detector and MCNPX code

  • Ayberk Yilmaz;Hatice Yilmaz Alan;Lidya Amon Susam;Baki Akkus;Ghada ALMisned;Taha Batuhan Ilhan;H.O. Tekin
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4671-4678
    • /
    • 2022
  • The purpose of this comprehensive research is to observe the impact of scintillator crystal type on entire detection process. For this aim, MCNPX (version 2.6.0) is used for designing of a physical plastic scintillation detector available in our laboratory. The modelled detector structure is validated using previous studies in the literature. Next, different types of plastic scintillation crystals were assessed in the same geometry. Several fundamental detector properties are determined for six different plastic scintillation crystals. Additionally, the deposited energy quantities were computed using the MCNPX code. Although six scintillation crystals have comparable compositions, the findings clearly indicate that the crystal composed of PVT 80% + PPO 20% has superior counting and detecting characteristics when compared to the other crystals investigated. Moreover, it is observed that the highest deposited energy amount, which is a result of the highest collision number in the crystal volume, corresponds to a PVT 80% + PPO 20% crystal. Despite the fact that plastic detector crystals have similar chemical structures, this study found that performing advanced Monte Carlo simulations on the detection discrepancies within the structures can aid in the development of the most effective spectroscopy procedures by ensuring maximum efficiency prior to and during use.

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

적은 수의 광센서를 사용한 PET 검출기 설계 (PET Detector Design with a Small Number of Photo Sensors)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.525-531
    • /
    • 2021
  • 양전자방출단층촬영기기의 검출기는 다수의 섬광 픽셀과 다수의 광센서를 사용하여 구성된다. 다수의 광센서를 사용함으로써 비용이 증가하고 신호처리가 복잡해진다. 본 연구에서는 적은 수의 광센서를 사용하여 비용의 감소와 간결한 신호처리가 가능한 검출기를 설계하였다. 섬광 픽셀과 적은 수의 광센서를 사용하고 모든 광센서에 빛을 전달하기 위해 광가이드를 사용하였다. 섬광 픽셀과 광가이드에는 광센서로 최대한의 빛을 전달하기 위해 반사체를 적용하였다. 반사체는 난반사체 및 거울반사체를 사용하였으며, 광가이드의 두께를 다르게 적용하여 평면 영상을 획득하였다. 획득된 평면 영상의 비교 분석을 통해 최적의 조합을 선택하였다. 그 결과 섬광 픽셀과 광가이드 모두 거울반사체를 사용하였을 경우, 모든 두께의 광가이드에서 우수한 평면 영상을 획득하였다. 광가이드는 섬광 픽셀의 영상이 형성된 지점의 분석 및 영상의 크기를 고려하여 3 mm 두께를 사용할 경우 최적의 영상이 획득되는 결과를 도출하였다.

광센서 크기에 따른 섬광 픽셀 배열의 최대화 연구 (A Study on the Maximization of Scintillation Pixel Array According to the Size of the Photosensor)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.157-162
    • /
    • 2022
  • 전임상용 양전자방출단층촬영기기는 인체에 비해 매우 작은 소동물을 대상으로 촬영이 이루어지므로, 우수한 공간분해능을 지닌 검출기가 필요하다. 이를 위해 작은 섬광 픽셀을 사용한 검출기를 사용하여 시스템을 구성하였다. 현재 개발되어 사용되는 광센서의 크기는 한정되어 있으므로, 이에 맞는 최소한의 섬광 픽셀과 최대의 배열로 구성할 경우 우수한 공간분해능을 얻을 수 있다. 본 연구에서는 광센서의 크기를 고정하고, 이에 맞는 다양한 섬광 픽셀의 배열을 구성하여 평면 영상에서 겹침이 발생하지 않고, 모든 섬광 픽셀들이 구분이 되는 최대의 섬광 픽셀 배열을 찾고자 한다. 이를 위해 섬광체와 광센서로 이루어진 검출기 모듈의 시뮬레이션이 가능한 DETECT2000을 사용하였다. 3 mm × 3 mm 픽셀이 4 × 4 배열로 이루어진 광센서를 사용하였으며, 섬광 픽셀 배열은 8 × 8에서부터 13 × 13까지 구성하여 시뮬레이션을 수행하였다. 광센서 픽셀에서 획득된 데이터를 통해 평면 영상을 구성하였으며, 평면 영상과 프로파일을 통해 영상의 겹침이 발생하지 않는 최대의 섬광 픽셀 배열을 찾았다. 그 결과 평면 영상에서 서로 겹침이 발생하지 않고 모든 섬광 픽셀들이 영상화되는 섬광 픽셀 배열의 크기는 11 × 11이었다.

적은 수의 광센서를 사용한 PET 검출기의 최대우도함수를 적용한 디지털 위치 측정 (Digital Position Measurement with MLPE of PET detector using a Small Number of Photosensors)

  • 강승훈;이승재
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-156
    • /
    • 2022
  • 적은 수의 광센서를 사용하는 검출기를 설계하고, 최대우도함수를 통해 감마선과 상호작용한 섬광 픽셀의 위치를 디지털 위치로 측정하는 연구를 수행하였다. 이를 위해 섬광체 내에서 빛의 이동을 모사할 수 있는 DETECT2000을 사용하여 시뮬레이션을 수행하였으며, 위치 측정의 정확도를 평가하였다. 6 × 6의 섬광 픽셀 배열과 4개의 광센서를 사용하여 검출기를 구성하였으며, 각 섬광 픽셀 중심에서 감마선 이벤트를 발생시켜 수집된 빛의 비율을 통해 순람표를 작성하였다. 새로운 위치에서 발생된 감마선 이벤트를 최대우도함수의 입력값으로 적용하여 순람표와 비교후 섬광 픽셀의 위치를 디지털 위치로 변환하였다. 모든 섬광 픽셀들에서 평가하였으며, 그 결과 99.1%의 높은 정확도를 획득하였다. 이러한 방법을 현재 사용되는 시스템에 적용할 경우 섬광 픽셀의 위치를 판별하는 과정의 간소화를 이룰 것으로 판단된다.

감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가 (Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution)

  • 신상훈;유욱재;장경원;조승현;이봉수
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

성능이 향상된 Stack Monitoring System의 설계 (Design of Stack Monitoring System with Improved Performance)

  • 장경욱;이주현;이승원;이승호
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.299-302
    • /
    • 2016
  • 본 논문에서는 성능이 향상된 Stack Monitoring System을 설계한다. Stack Monitoring System의 증폭기(AMP)에 들어오는 펄스성 잡음을 차단하기 위하여, 차폐 및 전원부 임피던스를 낮추고 전원회로를 분리하여 노이즈를 차단한다. 신틸레이션 검출기 특성을 최대한 장치에 매칭하기 위한 가변 고전압, 이득(Gain), 상쇄(Offset), 한계(Threshold) 등을 설정 할 수 있는 제어부를 설계한다. 또한 300 ~ 1,500V의 가변 고전압 전원회로를 구성하여 다양한 신틸레이션 검출기에 적용가능 한 가변 전압 공급 장치를 설계한다. 성능이 향상된 Stack Monitoring System은 다종의 신틸레이션 검출기가 각각의 특성을 고려하여 동작하게 함으로서 효율적이고 높은 신뢰성을 보장한다. 개발된 Stack Monitoring System의 측정 불확도에 대하여 공인 시험기관의 장비를 사용하여 실험한 결과 우수한 성능을 나타내었다.

Optimized TOF-PET detector using scintillation crystal array for brain imaging

  • Leem, Hyuntae;Choi, Yong;Jung, Jiwoong;Park, Kuntai;Kim, Yeonkyeong;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2592-2598
    • /
    • 2022
  • Research groups in the field of PET instrumentation are studying time-of-flight(TOF) technology to improve the signal-to-noise ratio of PET images. Scintillation light transport and collection plays an important role in improving the coincidence resolving time(CRT) of PET detector based on a pixelated crystal array. Four crystal arrays were designed by the different optical reflection configuration such as external reflectors and surface treatment on the CRT and compared with the light output, energy resolution and CRT. The design proposed in the study was composed of 8 × 8 LYSO crystal array consisted of 3 × 3 × 15 mm3 pixels. The entrance side was roughened while the other five surfaces were polished. Four sides of all crystal pixels were wrapped with ESR-film, and the entrance surface was covered by Teflon-tape. The design provided an excellent timing resolution of 210 ps and improved the CRT by 16% compared to the conventional method using a polishing treatment and ESR-film. This study provided a method for improving the light output and CRT of a pixelated scintillation crystal-based brain TOF PET detector. The proposed configuration might be an attractive detector design for TOF brain PET requiring fast timing performance with high cost-effectiveness.

Sensitivity of GAGG based scintillation neutron detector with SiPM readout

  • Fedorov, A.;Gurinovich, V.;Guzov, V.;Dosovitskiy, G.;Korzhik, M.;Kozhemyakin, V.;Lopatik, A.;Kozlov, D.;Mechinsky, V.;Retivov, V.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2306-2312
    • /
    • 2020
  • Here we report on the first results of sensitivity evaluation of the gadolinium-aluminum-gallium- garnet (GAGG) scintillation detector with SiPM readout to fast and slow neutrons and, to the natural background and Co-60 γ-radiation as well. Data on sensitivity were obtained using certified dosimetry benches, so it can be utilized in the calculation of detection limits of neutron flux with such type of detectors. It was concluded that use of GAGG scintillator has a good prospect for neutron monitoring in different parts of nuclear research reactors and power plants.

방사선 분포측정용 CsI(Tl) 검출기 설계 및 신호처리에 관한 연구 (The Study of CsI(Tl) Scintillation Detector Design and Signal Processing for the Measurement of the Radiation Distribution)

  • 황영관;이남호;김종열;정상훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.778-779
    • /
    • 2016
  • 본 논문에서는 공간상에 분포된 방사선원에 대해 화소단위로 방사선 신호를 탐지하기 위한 섬광 검출기를 설계하고, 탐지신호를 취득하기 위한 모듈을 설계하여 방사선 영상화를 위한 연구를 수행하였다. 방사선 분포측정을 위해 적용한 검출기는 CsI(Tl) 섬광체와 결합효율이 높은 수광센서로 구성하였으며, 수광센서를 통해 획득된 신호를 처리하기 위해 펄스 신호를 증폭, 성형 한 후 임계치를 기준으로 펄스를 계수하기 위한 장치를 구현하였다. 제작된 검출기의 성능을 검증하기 위해 감마선 교정시설을 이용하여 검출기에 대한 성능 시험을 수행하고 그 결과를 분석하였다. 본 논문의 결과는 제작된 검출기에 방향성을 부여하기 위한 차폐체 및 조사부를 적용한 후 방향을 이동시켜 개별적인 영역의 값을 2차원 적으로 나타냄으로써 선원의 분포측정을 위한 기초자료로 활용될 것이다.

  • PDF