• Title/Summary/Keyword: on-site test

Search Result 2,570, Processing Time 0.029 seconds

An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction (기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구)

  • Cho Bong Suk;Jang Jae Bong;Kim Yong Ro;Kang Suk Pyo;Hong Sung Yun;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

Applicability of Dynamic Compact Pilot Test on Waste Landfill (폐기물 매립장에서 동다짐공법의 적용성에 관한 연구)

  • 천병식;임병수;김명진
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.418-425
    • /
    • 2000
  • In this study, the evaluation for utilization of waste landfill was performed by field test to use waste landfill as construction site(Nangido in Seoul). The site where dynamic compaction test was carried out was divided by 4 yards. Yard 1, 2 were not eliminated widening of cover soil and Yard 3, 4 were eliminated it. Dynamic Compaction Pilot Test was carried out by the 15ton heavy tamper with drop height of 20m in Yard 1, 3 and with drop height of 15m in Yard 2, 4 We evaluated the compaction ability, optimum compaction number and noiseㆍvibration through field test, monitoring. To make use of waste landfill as a construction site, The dynamic compaction method is suitable for using in waste landfill as a construction site among the ground improvement methods.

  • PDF

The Study on Test for Control of Weeds Invasion in Constructed on Upper Embankment in the Shoulder of a Expressway (고속도로 갓길 외측 성토상단의 잡초침입 억제를 위한 시험 연구)

  • Jeon, Gi-seong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.227-237
    • /
    • 2015
  • From January 2013 to October 2015, weed invasion control techniques was tested in the test road of Jungbunaeryuk expressway so as to collect preliminary data for the management methods of the upper exterior banking of expressway shoulders. Then, monitoring was conducted and its results are as follows. Mat (sheet), solidifying agent, and mulching (wood chips) were applied for the test and their initial effects of preventing weed invasion were all excellent. It was found that the homogeneity of the wood chip mulching method needs to improve. In the mat method and the mulching method were found to have the most excellent economic feasibility and aesthetics, respectively. The covering degree was found to be the highest at 80% in the control site, followed by the wood chip site at 20% and the solidifying agent site and the non-woven fabric site at 5% each. As for species diversity, the control had the largest variety of species. Two years after the construction, many different species of plants invaded and were growing. Plants including weed didn't tend to invade the slopes applied with non-woven fabric. In addition, weed didn't invade the solidifying agent site and the aesthetics of the upper exterior banking of expressway shoulders was found to be excellent. The wood chip site was found to require consistent management for preventing weed invasion. The mat (sheet) site, the solidifying agent site, and the wood chip mulching site were found to have excellent weed prevention effects. As time passed, the mat (sheet) site and the solidifying agent site showed better weed prevention effects. However, they need consistent monitoring for further application.

A New Multi-site Test for System-on-Chip Using Multi-site Star Test Architecture

  • Han, Dongkwan;Lee, Yong;Kang, Sungho
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.293-300
    • /
    • 2014
  • As the system-on-chip (SoC) design becomes more complex, the test costs are increasing. One of the main obstacles of a test cost reduction is the limited number of test channels of the ATE while the number of pins in the design increases. To overcome this problem, a new test architecture using a channel sharing compliant with IEEE Standard 1149.1 and 1500 is proposed. It can significantly reduce the pin count for testing a SoC design. The test input data is transmitted using a test access mechanism composed of only input pins. A single test data output pin is used to measure the sink values. The experimental results show that the proposed architecture not only increases the number of sites to be tested simultaneously, but also reduces the test time. In addition, the yield loss owing to the proven contact problems can be reduced. Using the new architecture, it is possible to achieve a large test time and cost reduction for complex SoC designs with negligible design and test overheads.

Efficient Multi-site Testing Using ATE Channel Sharing

  • Eom, Kyoung-Woon;Han, Dong-Kwan;Lee, Yong;Kim, Hak-Song;Kang, Sungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.3
    • /
    • pp.259-262
    • /
    • 2013
  • Multi-site testing is considered as a solution to reduce test costs. This paper presents a new channel sharing architecture that enables I/O pins to share automatic test equipment (ATE) channels using simple circuitry such as tri-state buffers, AND gates, and multiple-input signature registers (MISR). The main advantage of the proposed architecture is that it is implemented on probe cards and does not require any additional circuitry on a target device under test (DUT). In addition, the proposed architecture can perform DC parametric testing of the DUT such as leakage testing, even if the different DUTs share the same ATE channels. The simulation results show that the proposed architecture is very efficient and is applicable to both wafer testing and package testing.

Site Attenuations of an Open Area Test Site (야회시험장의 시험장감쇠량)

  • 김기채;정연춘;정정환;정낙삼
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1336-1343
    • /
    • 1990
  • In this paper the theoretical analysis of the site attenuation was made on the concept of mutual impedance of antennas and the cause of characteristic hump in the site attenuation curve below 80 MHz is explained. The deviation between the FCC site attenuatios and the experimental results of an ideal open area test site at low frequencies(below 80MHz) was found to be the mutual coupling effects of the antennas under the FCC's measurement conditions. It seems desirable that the site attenuations curve of FCC document be revicused to the theoretical curves presented in this paper is long as the FCC's measurement conditions are to the applied.

  • PDF

On-line and Off-line Partial Discharge Monitoring System with HVAC Testing (HVAC에 의한 On-line, Off-line PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

Operation Cost Comparison of Dedicated Outdoor and Cooling + reheating Air-conditioning Systems by On-site Performance Test (현장성능시험에 의한 외기전용과 냉각식 + 재열 공조기의 운전비 비교)

  • Kim, Young-Il;Kim, Jung-Min;Chung, Kwang-Seop;Park, Seung-Tae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.37-42
    • /
    • 2011
  • Dedicated outdoor air(DOA) system which conditions the outdoor air separately is superior to conventional Cooling + reheating system with respect to energy consumption and indoor comfort. Since the sensible and latent load characteristics of indoor and outdoor are different, it is more efficient to treat them separately. In this study, cycle analysis and on-site performance test of DOA system have been conducted. The study shows that DOA requires 50% less equivalent energy than the conventional system. The on-site performance test of a prototype shows that the coefficient of performance(COP) of the DOA system is 37% higher than the conventional system.

The Performance Analysis and On-site Performance Test of a Dedicated Outdoor Air System (외기 전용 공조기의 성능 분석 및 현장 성능시험)

  • Kim, Young-Il;Kim, Jung-Min;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.346-351
    • /
    • 2007
  • Dedicated outdoor air(DOA) system which conditions the outdoor air separately is superior to conventional cooling+reheating system with respect to energy consumption and indoor comfort. Since the sensible and latent load characteristics of indoor and outdoor are different, it is more efficient to treat them separately. In this study, cycle analysis and on-site performance test of DOA system have been conducted. The study shows that DOA requires 48.8% less equivalent energy that conventional system. The on-site performance test of the prototype shows that the coefficient of performance(COP) of the DOA system is 37.4% higher than the conventional system.

  • PDF

On-line Condition Monitoring for Electric Equipments (전력 설비 시스템의 온라인 감시)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.103-105
    • /
    • 2008
  • In, this paper, we consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PO) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PO testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PO measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF