• Title/Summary/Keyword: line bundle

Search Result 81, Processing Time 0.03 seconds

Nontrivial Complex Equivariant Vector Bundles over $S^1$ (원 위에서의 Nontrivial Complex Equivariant Vector Bundle)

  • Kim, Sung-Sook
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.13-16
    • /
    • 1998
  • Every complex vector bundle over $S^1$ splits sum of line bundle and the first Chern class classify complex line bundle. This implies every complex vector bundle over $S^1$ is trivial. In this paper, we show the existence of some nontrivial complex vector bundle over $S^1$ in the equivariant case.

  • PDF

Analysis and Preventive Countermeasures of Power Line Twisting for 4-conductor bundle Transmission Line (4도체 송전선로의 전력선 염회 분석 및 방지 방안)

  • Min, B.W.;An, J.S.;NamKung, D.;Park, J.W.;Kim, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.406-410
    • /
    • 2001
  • For 4-conductor bundle transmission line spacer damper are equipped so as to keep the spacing between sub conductors. For 4-conductor bundle the subspan spacing of a spacer damper is determined and applied in order that the bundle may get restored to a normal state when 4-conductor bundle is rolled by rigid body vibration due to wind. But 4 conductors of 345kV 4-conductor bundle transmission line were twisted by the angle of $315^{\circ}$ for the first time korea. In this paper, we will analyze the reason of the power line twisting of 4-conductor bundle which occurred for the first time in korea and offer the preventive countermeasures for this

  • PDF

CLASSIFICATION OF THE EQUIVARIANT LINE BUNDLES OVER $S^1$ (원 위에서의 EQUIVARIANT LINE BUNDLE 의 분류)

  • Kim, Seong-Suk
    • The Journal of Natural Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-3
    • /
    • 1992
  • G가 compact Lie 군이고 $\pi$ : $E to S^1$$S^1$ 상의 G-line bundle 일때, 군 작용이 없다면, 부드러운 trivial G-line bundle $E to S^1$ 은 S(V) $\times$ $\delta to S(V)$ 와 동치이고 부드러운 nontrivial G-line bundle $E to S^1$ 은 S(V) $\times$$z_2$ $\delta to S(V)$/$Z_2$=P(V)와 동치 이다.

  • PDF

Equivariant vector bundle structures on real line bundles

  • Shu, Dong-Youp
    • Communications of the Korean Mathematical Society
    • /
    • v.11 no.1
    • /
    • pp.259-263
    • /
    • 1996
  • Let G be a topological group and X a G space. For a given nonequivariant vector bundle over X there does not always exist a G equivariant vector bundle structure. In this paper we find some sufficient conditions for nonequivariant real line bundles to have G equivariant vector bundle structures.

  • PDF

Impact of Central Line Insertion Bundle on the Adherence of Bundle and Central Line-Associated Bloodstream Infections in the Operating Room (수술실에서 중심정맥관 삽입 시 번들적용이 중심정맥관 관련 혈류감염에 미치는 영향)

  • Shin, Eun Jeong;Jeong, Jae Sim;Choi, Sang Ho;Huh, In Young
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.257-263
    • /
    • 2016
  • Background: This study purposed to examine how the incidence of the central line-associated bloodstream infection (CLABSI) in a operating room (OR) is affected by bundle application on central line insertion (CLI) practice. Methods: The study design was a pretest-posttest experimental trial. The subjects were 83 patients before the bundle application on CLI and 70 patients after. Results: The compliance(%) of bundle on CLI of among those who observed all of the five items increased from 7.2% before the intervention to 72.9% after. By items, compliance with the maximal barrier precaution was 100% for the use of a mask and cap before and after the intervention, but increased from 73.5% before the intervention to 88.6% after for the hand hygiene, from 73.5% to 88.6% for the use of a sterile gown, and from 9.6% to 75.7% for the use of a sterile large drape covering the whole body. CLABSI did not happen on CLI either before or after the application of the bundle intervention. Conclusion: Bundle application increased compliance with the use of a sterile gown and the use of a sterile large drape. However, its effect in the prevention of CLABSI was not clear probably due to the short period of intervention in a single hospital.

Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type (765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석)

  • Kim, Dae-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

Decreasing Technique of the Electric-field Intensity on Transmission Conductor Surface using the Hybrid Conductor Bundle (2종소도체 배열방식을 적용한 송전도체 표면전계강도 저감기법)

  • Lee, Dong-Il;Sin, Gu-Yong;Kim, Jeong-Bu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.542-549
    • /
    • 1999
  • Corona discharges form at the surface of a transmission line conductor when the electric-field intensity on the conductor surface exceeds the breakdown strength of air. In order to decrease the electric-field intensity on the conductor surface, a new 6 conductor bundle has been studied. This bundle, hybrid conductor bundle, consists of using a larger subconductor at the bottom two conductor positions in the 6-conductor bundles of each phase of the line. The electric field on these two larger subconductors is reduced which in turn reduces the corona noise. It is shown that this is a better solution for decreasing the electric-field intensity than ether the conventional bundle or the asymmetric bundle proposed by EPRI.

  • PDF

ANTI-LINEAR INVOLUTIONS ON A G-VECTOR BUNDLE

  • Kim, Sung-Sook;Shin, Joon-Kook
    • Communications of the Korean Mathematical Society
    • /
    • v.14 no.1
    • /
    • pp.211-216
    • /
    • 1999
  • We study the anti-linear involutions on a real algebraic vector bundle with bundle with a compact real algebraic group action.

  • PDF