• Title/Summary/Keyword: anchor end

Search Result 64, Processing Time 0.021 seconds

Pullout Resistance of Geosynthetic Strip with Rounded Band Anchor (수동저항부가 형성된 띠형 섬유보강재의 인발저항 특성)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.3
    • /
    • pp.43-51
    • /
    • 2011
  • This paper describes the results of pullout tests in the laboratory, which are conducted to assess the pullout performance of recently developed geosynthetic strip reinforcement with rounded band anchor. The geosynthetic strip can be used as reinforcements in reinforced soil wall with concrete block facing. The pullout resistance of the geosynthetic strip with rounded band anchor is mobilized by the combination of the interface friction between soil-reinforcement surface and the passive soil resistance caused by the rounded band anchor. Therefore, both the friction resistance and the passive resistance have to be considered in design. From the pullout test results, when the rounded band anchor are formed in the end part of the geosynthetic strip, pullout strength increases about from 10% to 65%. The passive resistance can be evaluated based on the pullout test results.

An analysis of anchor stones on the west and south coasts (서·남해안 출수 닻돌 분석)

  • PARK Seungmin
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.4
    • /
    • pp.6-22
    • /
    • 2022
  • In this paper classifies the types of 228 anchor stones discharged from the west and south coasts, assumes a combined method by type, routes through discharge locations, and It attempted to estimate the burial site. Prior to classification of types, the weight, thickness, width, and length of the anchor stone were measured, and the largest Young in the tomb The scent weight was classified into I~V groups, and the shape of the anchor stone was classified into 1-6 types. All of these weight and shape correlations It was classified into 17 types. The combined method by type is 180kg or less depending on the morphological characteristics of the reference value of the extracted anchor stone, and the type An anchor of type 1 or 2 is used in combination with an anchor, and a anchor of type 3 or 6 weighs more than 180kg and is combined with an anchor The dragon was assumed to be an anchor. Along with this, the route and burial site are identified through past records and testimony of local residents It was checked against the data. The route was largely consistent with past records, but the new route was apparent in waters near the island or inland It was also drawn. In the case of burial sites, small and large in Taean Mado Sea and Jindo Byeokpajin Sea, where anchor stones are concentrated, Considering the pattern of the type anchor stones being discharged, it was consistent with the testimony that ships of various sizes were mysterious in the two seas. Based on this type classification, a study on the spatiality of the anchors was conducted. First, a comparison and analysis was done on whether actual real data, such as anchor stones, old ships, and relics, were identified on the Joun-ro route and international trade routes as recorded in the past literature. Where there was no record, the route was estimated based on real data. To this end, routes estimated based on the testimony of local residents and modern ship workers were analyzed as to whether ships traveled there in the past and whether they could actually sail. Next, the location of each seedling was estimated by ship size according to the weight of the anchor stone. In the case of the Taean Mado Sea and Jindo Byeokpajin Sea, both small and large anchor stones were discharged from the coastline and were far away.

Mooring Cost Sensitivity Study Based on Cost-Optimum Mooring Design

  • Ryu, Sam Sangsoo;Heyl, Caspar;Duggal, Arun
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The paper describes results of a sensitivity study on an optimum mooring cost as a function of safety factor and allowable maximum offset of the offshore floating structure by finding the anchor leg component size and the declination angle. A harmony search (HS) based mooring optimization program was developed to conduct the study. This mooring optimization model was integrated with a frequency-domain global motion analysis program to assess both cost and design constraints of the mooring system. To find a trend of anchor leg system cost for the proposed sensitivity study, optimum costs after a certain number of improvisation were found and compared. For a case study a turret-moored FPSO with 3 ${\times}$ 3 anchor leg system was considered. To better guide search for the optimum cost, three different penalty functions were applied. The results show that the presented HS-based cost-optimum offshore mooring design tool can be used to find optimum mooring design values such as declination angle and horizontal end point separation as well as a cost-optimum mooring system in case either the allowable maximum offset or factor of safety varies.

Seismic behavior of simplified electrical cabinet model considering cast-in-place anchor in uncracked and cracked concretes

  • Bub-Gyu Jeon;Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Hong-Pyo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4252-4265
    • /
    • 2023
  • In the case of nuclear power plants near end of their design life, a reassessment of the performance of safetyrelated equipment may be necessary to determine whether to shut down or extend the operation of the power plant. Therefore, it is necessary to evaluate the level of performance decline due to degradation. Electrical cabinets, including MCC and switchgear, are representative safety-related equipment. Several studies have assessed the degradation and seismic performance of nuclear power plant equipment. Most of those researches are limited to individual components due to the size of safety-related equipment and test equipment. However, only a few studies assessed the degradation performance of electrical cabinets. The equipment of various nuclear power plants is anchored to concrete foundations, and crack in concrete foundations is one of the most representative of degradation that could be visually confirmed. However, it is difficult to find a study for analysis through testing the effect of cracks in concrete foundations on the response of electrical cabinet internal equipment fixed by anchors. In this study, using a simple cabinet model considering cast-in-place anchor in uncracked and cracked concretes, a tri-axial shaking table tests were performed and the seismic behavior were observed.

A study for construction of Shore-end Submarine cable (천해부에서 해저케이블 건설 연구)

  • Jung, Jae-Jin;Lee, Young-Sun;Shin, Hyun-Shik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.3
    • /
    • pp.185-190
    • /
    • 2007
  • The biggest cause of submarine cable fault is fishing activity such as 70% by anchor of fishing boats and occurs within 200m the depth of water. It needs a regulation for protection of submarine cable from the fishing boats and construction of cable at shore-end. This paper is studying a plan and regulation to install the construction among the subsee users, and the burial technique of submarine cable at shore-end suggests to manage from company to government.

  • PDF

Development of the Prefabricated Anchoring Device for External Strengthening (외부 강선 보강용 조립식 정착장치 개발 연구)

  • Han Man-Yop;Lee Sang-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.461-464
    • /
    • 2004
  • External prestressing method is the most papular method to strengthen concrete structures. The key parts of external prestressing method is an anchoring device which holds the prestressing cables. The most popular anchoring devices is an end bearing type, which has to be welded at site to assamble the anchor. The welding at site has a significant Quality problem. In this paper, new anchoring system has been developed, which needs no site welding. A design method for the new anchor has been proposed and developed to optimize the anchoring system. The developed anchors are very efficient, small, and compact, which have two types, one for abutment section and the other one for pier section. The anchors are expected to be used very widely, because of its convinience.

  • PDF

Experimental Analysis of Terminus and Horizontal Crack Behaviors in Continuously Reinforced Concrete Pavement (연속철근 콘크리트 포장 단부 및 수평균열 거동 실험적 분석)

  • Cho, Young-Kyo;Kim, Seong-Min;An, Zuog;Han, Seung-Hwan
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.81-91
    • /
    • 2011
  • This study was conducted to evaluate the necessity of the anchor lug system in continuously reinforced concrete pavement(CRCP) by comparing longitudinal displacements of CRCPs with and without anchor lugs, and to investigate the effect of horizontal cracking on CRCP performance by measuring the vertical displacements. The measurements before and after the anchor lug section was separated were conducted for 12 days in June, and for 14 days in August after the abrupt displacements according to cutting disappeared, respectively. This short term measurement results showed that when anchor lugs were installed, a daily displacement variation at any location was less than 0.1mm; therefore, longitudinal movements were negligibly small. When there were no anchor lugs, longitudinal displacements mainly occurred near the free end and the displacement variation was small; therefore, an expansion joint system seems to be employed at a CRCP terminus without installing anchor lugs. However, further studies are needed to verify the terminus behavior due to annual temperature changes. The horizontal crack width variation was ignorable and did not affect the vertical displacement of the slab. Therefore, the horizontal crack did not delaminate the slab and did not seem to reduce the structural capacity and performance of CRCP.

A strain-based wire breakage identification algorithm for unbonded PT tendons

  • Abdullah, A.B.M.;Rice, Jennifer A.;Hamilton, H.R.
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.415-433
    • /
    • 2015
  • Tendon failures in bonded post-tensioned bridges over the last two decades have motivated ongoing investigations on various aspects of unbonded tendons and their monitoring methods. Recent research shows that change of strain distribution in anchor heads can be useful in detecting wire breakage in unbonded construction. Based on this strain variation, this paper develops a damage detection model that enables an automated tendon monitoring system to identify and locate wire breaks. The first part of this paper presents an experimental program conducted to study the strain variation in anchor heads by generating wire breaks using a mechanical device. The program comprised three sets of tests with fully populated 19-strand anchor head and evaluated the levels of strain variation with number of wire breaks in different strands. The sensitivity of strain variation with wire breaks in circumferential and radial directions of anchor head in addition to the axial direction (parallel to the strand) were investigated and the measured axial strains were found to be the most sensitive. The second part of the paper focuses on formulating the wire breakage detection framework. A finite element model of the anchorage assembly was created to demonstrate the algorithm as well as to investigate the asymmetric strain distribution observed in experimental results. In addition, as almost inevitably encountered during tendon stressing, the effects of differential wedge seating on the proposed model have been analyzed. A sensitivity analysis has been performed at the end to assess the robustness of the model with random measurement errors.

Bearing Reinforcing Effect of Concrete Block with a Round End according to the Application of Aluminum Stiffener (알루미늄 보강재 적용에 따른 원형 단부 콘크리트 블록의 지압 보강 효과)

  • Seok Hyeon Jeon;Tae-Yun Kwon;Jin-Hee Ahn
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2023
  • In this study, a bearing test was performed and analytically evaluated to evaluate the bearing performance according to the application of the aluminum stiffener in round-end concrete. In the bearing strength test, the change in bearing performance due to the aluminum stiffener using the aluminum form for manufacturing concrete with round-end, and the steel anchor bolts for member movement and assembly was confirmed. The FE analysis model was identically configured to the experimental conditions, and the result was compared with the experiment. Also, the crack patterns and stress behavior were confirmed. In addition, the effect of strength change of the aluminum stiffener on the round-end concrete was also evaluated analytically. The bearing strength of the round-end concrete increased by about 20% due to the aluminum stiffener, and it was confirmed that the steel anchor bolt did not affect the bearing strength. The maximum load and crack patterns shown as a result of FE analysis were similar to those of the experiment. As a result of FE analysis according to the strength change of the aluminum stiffener, the maximum load change according to the increase and decrease of the strength of the aluminum stiffener by 10% and 20% was evaluated to have no significant effect at a maximum of about 4% compared to before the strength change.

A Study on the Fatigue Characteristics to Improve the Eng Bond Properties of Strengthening Concrete Beam (단부 부착력 개선을 위한 보강콘크리트보의 피로특성에 관한 연구)

  • 한만엽;이영헌;이성준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.721-724
    • /
    • 1999
  • The concrete structure under fatigue load depresses in mechanical capability or breaks down finally because of the fatigue. So recently the study on strengthening methods using bonded plate is widely attended. Which could be constructed under use and without damaging the structure. The intention of this method is to increase the useability of the structure and to recover the strength. So application on fields are sharply increasing. In this study it is tried to develop strengthening methods using notches and anchor bolts which could supply the defect on falling off of the plate at the end.

  • PDF