1 |
Abdullah, A.B.M., Rice, J.A. and Hamilton, H.R. (2014a), "Wire breakage detection using relative strain variation in unbonded posttensioning anchors", J. Bridge Eng., 10.1061/(ASCE)BE.1943-5592.0000639, 04014056.
DOI
|
2 |
Abdullah, A.B.M., Rice, J.A. and Hamilton, H.R. (2014b), "A damage detection model for unbonded post-tensioning tendons based on relative strain variation in multi-strand anchors", Proceedings of the SPIE Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems, San Diego, CA, March.
|
3 |
ASTM. (2006), "Standard specification for steel strand, uncoated sevenwire for prestressed concrete", A416, West Conshohocken, PA.
|
4 |
Bartoli, I., Salamone, S., Phillips, R., Lanza di Scalea, F. and Sikorsky, C.S. (2011), "Use of interwire ultrasonic leakage to quantify loss of prestress in multiwire tendons", J. Eng. Mech. -ASCE, 137(5), 324-333.
DOI
|
5 |
Bastien, J., Marceau, D., Fafard, M. and Chabert, A. (1996), "Experimental and numerical study of multi-strands wedge anchor heads", Symposium on Post-Tensioned Concrete Structures, Concrete Society, Slough, U.K.
|
6 |
Bastien, J., Marceau, D., Fafard, M. and Ganz, H.R. (2007), "Use of FEA for design of posttensioning anchor head", J. Bridge Eng., 12(2), 194-204.
DOI
ScienceOn
|
7 |
Chen, H.L.R. and Wissawapaisal, K. (2001), "Measurement of tensile forces in a seven-wire prestressing strand using stress waves", J. Eng. Mech. -ASCE, 127(6), 599-606.
DOI
|
8 |
Corven Engineering (2002), New directions for Florida post-tensioned bridges: Vol. 1: Post-tensioning in Florida bridges, Technical Report, Florida Department of Transportation (FDOT), Tallahassee, FL, Available at http://www.dot.state.fl.us/structures/posttensioning.shtm
|
9 |
Cullington, D.W., MacNeil, D., Paulson, P. and Elliott, J. (2001), "Continuous acoustic monitoring of grouted post-tensioned concrete bridges", NDT&E Int., 34(5), 95-105.
DOI
|
10 |
Elsener, B. (2008), "Monitoring of electrically isolated post-tensioning tendons", Tailor made concrete structures, Taylor & Francis, London.
|
11 |
Fricker, S. and Vogel, T. (2007), "Site installation and testing of a continuous acoustic monitoring", Constr. Build. Mater., 21(3), 501-510.
DOI
|
12 |
Lanza di Scalea, F., Rizzo, P. and Seible, F. (2003), "Stress measurement and defect detection in steel strands by guided stress waves", J. Mater. Civ. Eng., 15(3), 219-227.
DOI
|
13 |
Lau, K., Lasa, I. and Paredes, M. (2013), "Corrosion failure of post-tensioned tendons in presence of deficient grout", Proceedings of the NACE International CORROSION 2013, Orlando, FL, March.
|
14 |
Nguyen, K.D. and Kim, J.T. (2012), "Smart PZT-interface for wireless impedance-based prestess-loss monitoring in tendon-anchorage connection", Smart Struct. Syst., 9(6), 489-504.
DOI
|
15 |
Liu, W., Hunsperger, R.G., Folliard, K., Chajes, M.J., Barot, J. and Jhaveri, D. (1999), "Detection and characterization of corrosion of bridge cables by time domain reflectometry", Proceedings of the SPIE Nondestructive Evaluation of Bridges and Highways III, Bellingham, WA.
|
16 |
Liu, W., Hunsperger, R.G., Chajes, M.J., Folliard, K.J. and Kunz, E. (2002), "Corrosion detection of steel cables using time domain reflectometry", J. Mater. Civ. Eng., 14(3), 217-223.
DOI
|
17 |
Marceau, D., Bastien, J. and Fafard, M. (2001), "Experimental and numerical studies of mono-strand anchorage", Struct. Eng. Mech., 12(2), 119-134.
DOI
ScienceOn
|
18 |
Salamone, S., Bartoli, I., Phillips, R., Nucera, C. and Lanza di Scalea, F. (2011), "Health monitoring of prestressing tendons in posttensioned concrete bridges", Transportation Research Record 2220, Transportation Research Board, Washington, DC.
|
19 |
Salamone, S., Veletzos, M.J., Lanza di Scalea, F. and Restrepo, J.I. (2012), "Detection of initial yield and onset of failure in bonded posttensioned concrete beams", J. Bridge Eng., 17(6), 966-974.
DOI
|
20 |
Scheel, H. and Hillemeier, B. (2003), "Location of prestressing steel fractures in concrete", J. Mater. Civ. Eng., 15(3), 228-234.
DOI
|
21 |
Tabatabai, H., Mehrabi, A.B. and Yen, W.P. (1998), "Bridge stay cable condition assessment using vibration measurement techniques", Proceedings of the SPIE Structural Materials Technology III: An NDT Conference, Bellingham, WA.
|
22 |
Zejli, H., Gaillet, L., Laksimi, A. and Benmedakhene, S. (2012), "Detection of the presence of broken wires in cables by acoustic emission inspection", J. Bridge Eng., 17(6), 921-927.
DOI
|
23 |
Wang, M.L., Chen, Z.L., Koontz, S.S. and Lloyd, G.M. (2000), "Magnetoelastic permeability measurement for stress monitoring in steel tendons and cables", Proceedings of the SPIE Nondestructive Evaluation of Highways, Utilities, and Pipelines IV, Bellingham, WA.
|
24 |
Yuyama, S., Yokoyama, K., Niitani, K., Ohtsu, M. and Uomoto, T. (2007), "Detection and evaluation of failures in high-strength tendon of prestressed concrete bridges by acoustic emission", Constr. Build. Mater., 21(3), 491-500.
DOI
|