• 제목/요약/키워드: Unit Module

검색결과 831건 처리시간 0.03초

고속 네트워크 시스템의 이중화 회로 구현 (Implementation of High Speed Router's Redundancy Architecture)

  • 강덕기;이상우;이준철;이형섭;이영천
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.267-270
    • /
    • 2000
  • In this paper, we consider the simple redundant structures with the function of hardware based active/standby control. The system includes two switch modules. The switch module is connected to a data bus, but only the active switch module has control of the data bus. The standby unit takes over the function of the active unit when the active unit failure or mode command are asserted. And this paper illustrate the high-speed router system and the overall redundant system architecture. The proposed redundant architecture for 80G Router system is verified and implemented with experiment.

  • PDF

기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성( II ) (Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using High Performance Polymer Membranes( II ))

  • 이재달;홍영기;노덕길;배기서
    • 한국염색가공학회지
    • /
    • 제17권4호
    • /
    • pp.21-26
    • /
    • 2005
  • A combination separation system is composed of three parts, simple microfiltration unit for the pretreatment of real waste IPA, pervaporation unit with plate and frame type module(the effective membrane area 9,040$cm^2$), and simple ultrafiltration unit as a refiner. Utrafiltration module with hollow fiber membrane(MWCO 10,000) used to purify waste aqueous IPA solution. In addition, the flux of $CMPA-K^+$ composite membrane for waste aqueous IPA solution was very steady-state with long experiment time(30 days). And the standard deviation($\sigma$) was 0.152 and then the coefficient of variation($CV\%$)was 10.82 The IPA concentration on the membrane performance using pervaporation module system could be increased from $89.85wt(\%)$ to more than $99.90wt\%$ in about 8hr at operation temperature of $70^{\circ}C$ using the pervaporation module system. Therefore, a combination separation process system of simple filtration and pervaporation was very effective for the purpose of the IPA purification and reuse front industrial electronic components cleaning process.

Implementation of Unmanned Remote supervisory System having Multipurpose Measuring Modules

  • Park, Jung-Hoon;Hong, Sung-Hoon;Kang, Moon-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.132.1-132
    • /
    • 2001
  • In this paper, we have studied for development of unmanned remote supervisory system using mobile communication network, not wire network, not to be affected by space or distance. The unmanned remote supervisory system consists of data processing unit main part and measuring systems (modules part)-temperature measuring module, humidity measuring module and human body sensing module. The data processing unit to collect and process informations of each measuring module has the functions of data communication between a mobile cellular telephone and measuring systems. Each measuring module has supervisory and warning functions for a target of supervision. And then we have designed each system and evaluated accuracy and reliability of the combined total system.

  • PDF

환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석 (Comparison of Performance Analysis of the Ventilated and Non-­ventilated CIGS BIPV Units)

  • 김상명;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.47-57
    • /
    • 2017
  • CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was $6.8^{\circ}C$ lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

가변적 평면이 가능한 컨테이너 모듈형 조립식 공동주택의 건축계획 (Variable apartment building planning by using combinable container house module)

  • 조태흠;진경일
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.95-100
    • /
    • 2017
  • Purpose: Now a day, Most of the residential house in Korea consists of apartment buildings. However, in the case of old apartment buildings, dwelling environment condition depends on management effort by residents. But we can't rebuild or restructure only old single dwelling unit in apartment buildings. And we can't move every single dwelling unit in the apartment building. Therefore, this study suggests a prototype of combinable container dwelling module apartment. Method: The method of research is exploring the case of previously constructed containers. Based on the case, This study suggests prototypes to create a variable apartment design with dwelling container units. Based on the prototype, various combinations are proposed to produce various types of dwelling space. Finally, this study makes an example plan for the apartment by using the container unit modules. Results: This study suggests combinable container apartment building prototypes. And it may be a fundamental study of changing the apartment building concept.

A design of a floating point unit with 3 stages for a 3D graphics shader engine

  • Lee, Kwang-Yeob
    • 전기전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.358-363
    • /
    • 2007
  • This paper presents a floating point unit(FPU) with 3 stages for a 3D graphics shader engine. It targeted to accelerate 3D graphics in portable device environments. In order to design a balanced architecture for a shader engine, we analyzed shader assembly instructions and estimated the performance of FPU with the method we propose. The proposed unit handles 4-dimensional data through separated two paths that are lead to general operation module and special function module. The proposed FPU is compiled as a form of the cascade FPU with 3 stages to efficiently handle a matrix operation with relatively low hardware overhead. Except some complex instructions that are executed using macro instructions, all instructions complete an operation in a single instruction cycle at 100MHz frequency. A special function module performs all operations in a single clock cycle using the Newton Raphson method with the look-up table.

  • PDF

대규모 네트워크를 위한 침입 탐지결정모듈 설계 (PUM: Processing Unit Module Design of Intrusion Detector for Large Scale Network)

  • 최인수;차홍준
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권2호
    • /
    • pp.53-58
    • /
    • 2002
  • 인터넷 사용의 일반화는 정보보호라는 새로운 도구화를 요구하게 되었다. 따라서 정보시스템에 대한 침입, 정보 탈취, 변경 및 훼손 또는 의도적인 유출에 따르는 정보 보호는 시스템보호를 위한 시스템사용자 인준 문제에서 외부로부터 침입 탐지의 필요성이 요구된다. 그러므로 이 문제에서 여러 가지 사례의 지능화 침입 수법에 대한 호스트 로그(host log)를 분석하고, 네트워크_패킷(network_packet)을 분석해 대규모 네트워크 환경에서 이용할 수 있는 침입 탐지결정모듈 PUM(Processing Unit Module)설계를 제안한다.

  • PDF

비정형 파사드의 유닛 모듈 시공 공법 개발 (Unit Module Construction Method for Freeform Facade)

  • 김성진;박성진;박영미;류한국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.220-221
    • /
    • 2013
  • Exterior walls are designed and constructed through design focused exterior wall system. Nowadays, freeform facade design has been changing according to material, form and function of the exterior wall system. Especially, curtain wall facade system is designed and manufactured using solar shading faces. However, the traditional method have a lot of difficulties in the currently performing technology for curtain wall facade. It is important to make the freeform facade components that integrated as a surface of freeform buildings. Therefore it is necessary to develop unit module construction method for freeform facade.

  • PDF

무인 원격감시 시스템용 계측 모듈 및 데이터 처리장치의 구현 (Implementation of Measuring Modules & Data Processing Unit for Unmanned Remote Supervisory System)

  • 박정훈;홍성훈;서강면;강문성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2209-2211
    • /
    • 2001
  • Unmanned remote supervisory system consists of data processing unit and measuring systems-temperature measuring module, humidity measuring module and human body sensing module. The data processing unit to collect and process informations of each measuring modules has functions of data communication between a mobile cellular-telephone and measuring systems.

  • PDF

원자력 및 핵의학 분야용 Total RMS (Radiation Monitoring System)의 설계 (Design of Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.158-161
    • /
    • 2017
  • 본 논문에서는 원자력 및 핵의학 분야용 Total RMS(Radiation Monitoring System)를 제안한다. 제안하는 시스템은 Stack Monitor, Area Monitor, Water(Liquid) Monitor 등을 하나의 시스템으로 확장 및 제어할 수 있는 장비로 각 방사선 검출기에서 측정된 신호를 통합 모니터링 할 수 있다. 제안하는 시스템은 해당 방사선을 검출하는 Sensor Module, 방사선 검출 위치에 인접한 곳에서 방사선량을 디스플레이 하는 Display Unit, 검출된 방사선량이 위험 수준에 도달시 경보를 알리는 Alarm Unit, 각 모니터링에서 측정된 방사선량들을 취합하고 저장하여 원격 감시 시스템에 내용을 전달하는 Main Hub, 원격지에서 측정된 방사선량 상태를 일목요연하게 디스플레이 하는 RMS Monitoring Unit 등으로 구성된다. 제안된 원자력 및 핵의학 분야용 Total RMS의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 측정 불확도가 8.5%이하로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.