• 제목/요약/키워드: Tubular Membrane

검색결과 189건 처리시간 0.024초

응집제와 관형막을 활용한 CMP 폐수 처리 가능성 연구 (The Feasibility Study of CMP Wastewater Treatment Using Tubular Membrane and Coagulants)

  • 정호찬;정철중;송자연;김연국;이선용
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.639-645
    • /
    • 2012
  • The purpose of this study is to identify the possibility of the CMP wastewater treatment from semiconductor fabrication under operating tubular membrane with coagulants. To find suitable coagulants treating CMP wastewater, we conducted Jar-test. After Jar-test experiments suitable coagulants are PAC(17%), $Ca(OH)_2$ and optimum coagulant dosage is PAC(17%) 10mg/L, $Ca(OH)_2$ 110 ~ 120mg/L. Based on these results, the tubular membrane was applied to CMP wastewater, the turbidity removal efficiency is $Ca(OH)_2$ > PAC(17%) > Nothing. The fast cross-flow velocity and backwash process what are operating characteristics of tubular membrane can be stable CMP wastewater treatment. But when the coagulant and tubular membrane are used at the same time, the withdraw and treatment of the CMP wastewater are possibile. However further treatment process needs if treated water will be used for semiconductor fabrications.

정수장 배출수 처리를 위한 Crossflow 관형막 여과 공정의 운전 적용에 관한 연구 (A Study about Applicability of Treatment for Water Treatment Residual Sludge Using Crossflow Tubular Membrane System)

  • 김영훈;김관엽;김지훈;이용수;이의종;엄정열;김형수;황선진
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.499-505
    • /
    • 2009
  • Many other countries have investigated the residual sludge treatment process to save the existing water resource and produce the high suspended solid concentration sludge. There are various methods for concentrating residual sludge, but the membrane system has received the most interest for its efficiency. The objective of this study was to evaluate the application of membrane filtration system for the residual sludge treatment. The experiment equipment was composed of Lab scale Crossflow tubular membrane filtration system. Generally, crossflow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, very low Crossflow velocity was used in this experiment. Results confirmed that suspended solid concentration of residual sludge could be concentrated to 57,000mg/L in low Crossflow velocity tubular membrane system,. This concentration can be directly injected into the dehydrator. Based on the results, we know that the Crossflow tubular membrane system should be replaced conventional residual sludge treatment system.

Advanced Water Treatment by Tubular Alumina Ceramic Ultrafiltration: Effect of Periodic Water-back-flushing Period

  • Park, Jin-Yong;Lee, Song-Hui
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • The periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic ultrafiltration (UF) system for Gongji stream water treatment in Chuncheon city. The filtration time (FT), which was the water-back-flushing period, 2 min with periodic 15 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 6.35 L. Consequently FT 2 min at back-flushing time (BT) 15 sec could be the optimal condition in advanced UF water treatment of Gongji stream. Then the average rejection rates of pollutants by our tubular ceramic UF system were 99.4% for Turbidity, 31.8% for $COD_{Mn}$, 22.6% for $NH_3$-N and 65.9% for T-P.

역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구 (A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode)

  • 엄정열;김관엽;김영훈;송준섭;김형수;한명애;양형석
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

Effects of ring number and baffled-ring distances on ultrafiltration in the tubular membrane inserted concentrically with a ring rod

  • Yeh, Ho-Ming;Ho, Chii-Dong;Li, Cha-Hsin
    • Membrane and Water Treatment
    • /
    • 제3권1호
    • /
    • pp.51-62
    • /
    • 2012
  • The permeate flux declination along an ultrafilter membrane is due mainly to the concentration-polarization resistance increment and the decline in transmembrane pressure. It was found in previous works that the concentration polarization resistance could be reduced in a ring-rod tubular membrane ultrafilter using the turbulent behavior. In the present study, the performance was further improved by properly and gradually decreasing the baffled-ring distance along the cross-flow channel coupled with properly adjusting the number of baffled rings. This theoretical analysis is based on the mass and momentum balances as well as the application of the resistance-in-series model. The correlation predictions are confirmed with the experimental results for dextran T500 aqueous solution ultrafiltration.

Effect of Periodic Water-back-flushing Time ad Period in Water Treatment by Tubular Alumina Ceramic Microfiltration

  • Park, Jin-Yong;Lee, A-Reum
    • Korean Membrane Journal
    • /
    • 제10권1호
    • /
    • pp.33-38
    • /
    • 2008
  • In this study periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic micro filtration system for Gongji stream water treatment in Chuncheon city. The filtration time (FT) 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_0$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 7.44L. Also in the results of BT effect at fixed FT 10 min, BT (back-flushing time) 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_0$, and we could be obtained the highest $V_T$ of 8.04 L. Consequently FT 10 min and BT 20 sec could be the optimal condition in Gongji stream water treatment. Then the average rejection rates of pollutants by our tubular ceramic MF system were 93.8% for Turbidity, 20.7% for $COD_{Mn}$, 39.2% for $NH_3$-N and 31.5% for T-P.

연속식 공기세정 관형막 투과특성 (Permeation Characteristics of the Tubular Membrane with Continuous Air Cleaning System)

  • 박미자;정건용
    • 멤브레인
    • /
    • 제23권2호
    • /
    • pp.185-188
    • /
    • 2013
  • 본 연구는 정밀여과용 관형 분리막 모듈 내에 자체 설계한 기체분사형 노즐을 장착하여 막오염 감소 효과에 따른 투과유속을 측정하였다. 원료 용액으로는 0.1 wt% yeast 입자를 사용하였으며 공기 주입에 따른 막오염 감소 효과를 확인하기 위하여 공기를 주입하지 않은 경우와 주입한 경우의 투과유속을 비교 분석하였다. 공기를 주입하지 않았을 경우 투과유속은 지속적으로 감소하였지만 공기를 주입할 경우 투과유속은 공기를 주입하지 않은 경우와 비교하여 30% 이상 향상됨을 확인하였다.

관형 알루미나 세라믹 한외여과막에 의한 고도정수처리 시스템에서 물 역세척의 영향 (Effect of Water-back-flushing in Advanced Water Treatment System by Tubular Alumina Ceramic Ultrafiltration Membrane)

  • 박진용;이송희
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.194-202
    • /
    • 2009
  • 본 연구에서 처리수를 이용한 주기적인 역세척은 춘천시 공지천의 관형 세라믹 한외여과막에 의한 고도정수처리 시스템에서 막오염을 저감하고 투과선속을 향상시키고자 수행되었다. 일정한 역세척 시간(BT) 15초에서 여과시간 즉, 물 역세척 주기(FT) 2분이 가장 높은 무차원 투과선속(초기 투과선속에 대한 투과선속)과 가장 낮은 막오염 저항값을 보였다. 또한, FT 10분으로 고정한 BT 영향의 결과에서 BT 20초가 가장 낮은 막오염 저항과 가장 높은 무차원 투과선속을 나타내어, 가장 많은 총여과부피 107.3 L를 얻을 수 있었다. 결론적으로 공지천의 정수처리에서 FT 10분과 BT 20초가 최적조건으로 관형 알루미나 정밀여과의 선행 연구결과와 정확히 일치하였다. 한편 관형 세라믹 한외여과 시스템에 의한 오염물질 평균제거율은 탁도 97.0%, 망간법에 의한 COD 32.1%, 암모니아성 질소 28.8%, 총인 54.4%로 나타났다.

공기주입 노즐관이 장착된 관형막의 투과특성 (Permeation Characteristics of the Tubular Membrane Module Equipped wtih the Air Injection Nozzle Tube)

  • 박미자;정건용
    • 멤브레인
    • /
    • 제27권1호
    • /
    • pp.43-52
    • /
    • 2017
  • 분리막 오염을 감소시키고 투과유속 향상을 위하여 관형분리막 모듈 내에 공기 분사노즐관을 삽입시켰다. 분리막의 평균 기공크기는 $0.1\;{\mu}m$이며 이스트를 오염물질로 사용하였다. 모든 투과실험은 노즐관을 모듈에 장착하고 공기를 주입하지 않는 실험을 먼저 실시하고 연속해서 공기를 주입하는 투과실험을 하였다. 그 다음 노즐관을 제거한 후 공기를 주입시키지 않으면서 투과유속을 측정하였다. 측정된 투과유속은 공기주입 효과를 분석하기 위하여 비교하였다. 공기주입에 대한 투과유속은 거의 일정하거나 증가하였다. 노즐관이 장착되고 공기 주입을 하지 않을 경우의 투과유속이 빈 관형 모듈의 경우보다 높았다. 운전압력을 0.4 bar까지 감소시키면 노즐관이 장착되지 않는 경우와 비교하여 공기를 주입할 경우 투과유속이 21%까지 향상되었다. 기체량이 증가하여 기/액체 2상 흐름이 stratified-smooth에서 intermittent 상태로 변화됨에 따라서 공기 주입에 의한 투과유속은 30% 이상으로 증가하였다.