Browse > Article

Effect of Periodic Water-back-flushing Time ad Period in Water Treatment by Tubular Alumina Ceramic Microfiltration  

Park, Jin-Yong (Department of Environmental Sciences & Biotechnology, Hallym University)
Lee, A-Reum (Department of Environmental Sciences & Biotechnology, Hallym University)
Publication Information
Korean Membrane Journal / v.10, no.1, 2008 , pp. 33-38 More about this Journal
Abstract
In this study periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic micro filtration system for Gongji stream water treatment in Chuncheon city. The filtration time (FT) 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_0$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 7.44L. Also in the results of BT effect at fixed FT 10 min, BT (back-flushing time) 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_0$, and we could be obtained the highest $V_T$ of 8.04 L. Consequently FT 10 min and BT 20 sec could be the optimal condition in Gongji stream water treatment. Then the average rejection rates of pollutants by our tubular ceramic MF system were 93.8% for Turbidity, 20.7% for $COD_{Mn}$, 39.2% for $NH_3$-N and 31.5% for T-P.
Keywords
microfiltration; ceramic membrane; water treatment; water-back-flushing; tubular;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 J. Y. Park, G. Y. Kyung, S. H. Han, H. W. Kim, and H. C. Lee, 'Lake water treatment using ceramic ultrafiltration membrane system with periodic water-back-flushing', Korean Membrane J., 8(1), 50 (2006)   과학기술학회마을
2 W. Yuan, A. Kocic, and A. L. Zydney, 'Analysis of humic acid fouling during microfiltration using a pore blockage-cake filtration model', J. Membr. Sci., 198, 51 (2002)   DOI   ScienceOn
3 F. Malek, J. L. Harris, and F. A. Roddick, 'Interrelationship of photooxidation and microfiltration in drinking water treatment', J. Membr. Sci., 281, 541 (2006)   DOI   ScienceOn
4 H. C. Lee and J. Y. Park, 'Water Treatment of High Turbid Source by Tubular Ceramic Microfiltration with Periodic Water-back-flushing System', Korean Membrane J., 9(1), 12 (2007)   과학기술학회마을
5 V. T. Kuberkar and R. H. Davis, 'Microfiltration of protein-cell mixtures with crossflushing or backflushing', J. Membr. Sci., 183, 1 (2001)   DOI   ScienceOn
6 L. Fiksdal and T. O. Leiknes, 'The effect of coagulation with MF/UF membrane filtration for removal of virus in drinking water', J. Membr. Sci., 279, 364 (2006)   DOI   ScienceOn
7 M. H. Kim and J. Y. Park, 'Membrane fouling control effect of periodic water-back-flushing in the tubular carbon ceramic ultrafiltration system for recycling paper wastewater', Membrane Journal, 11(4), 190 (2001)
8 J. Y. Park, S. J. Choi, and B. R. Park, 'Effect of $N_2$-back-flushing in multichannels ceramic microfiltration system for paper wastewater treatment', Desalination, 202, 207 (2007)   DOI   ScienceOn
9 Y. T. Lee and J. K. Oh, 'Membrane fouling effect with organic-inorganic materials using the membrane separation in drinking water treatment process', Membrane Journal, 13(1), 219 (2003)
10 R. H. Davis, S. Redkar, and V. T. Kuberkar, 'Modeling of concentration and depolarization with high-frequency backpulsing', J. Membr. Sci., 121, 229 (1996)   DOI   ScienceOn