• Title/Summary/Keyword: Transmission waveform

Search Result 115, Processing Time 0.025 seconds

Signal Transient and Crosstalk Model of Capacitively and Inductively Coupled VLSI Interconnect Lines

  • Kim, Tae-Hoon;Kim, Dong-Chul;Eo, Yung-Seon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.260-266
    • /
    • 2007
  • Analytical compact form models for the signal transients and crosstalk noise of inductive-effect-prominent multi-coupled RLC lines are developed. Capacitive and inductive coupling effects are investigated and formulated in terms of the equivalent transmission line model and transmission line parameters for fundamental modes. The signal transients and crosstalk noise expressions of two coupled lines are derived by using a waveform approximation technique. It is shown that the models have excellent agreement with SPICE simulation.

Analysis of Lightning Overvoltage on the Combined Power Transmission Line and Actuation of Arrester (혼합송전계통에서 뇌과전압해석 및 피뢰기 동작특성 검토)

  • Kim, Nam-Yoel;Kim, Kyoung-Ho;Lee, Jong-Beom;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.491-493
    • /
    • 2001
  • This paper describes the effect of lightning current on combination transmission line. In the paper, an lightning current which can generate 2/80[${\mu}s$]. 20[kA] - 40[kA] waveform is modeled in ATPDraw. The lightning current invaded to the overhead power transmission line propagates to the underground power cable. The simulation was performed to analyze the effect of arrester location and overvoltage occurred in power cable.

  • PDF

An Information Transmission Method of the DC Switchgear for Light Railway Vehicle (경량전철용 직류배전반의 정보 전송방식)

  • Lee, H.D.;Kim, S.N.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

Verilog Modeling of Transmission Line for USB 2.0 High-Speed PHY Interface

  • Seong, Ki-Hwan;Lim, Ji-Hoon;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.463-470
    • /
    • 2014
  • A Verilog model is proposed for transmission lines to perform the all-Verilog simulation of high-speed chip-to-chip interface system, which reduces the simulation time by around 770 times compared to the mixed-mode simulation. The single-pulse response of transmission line in SPICE model is converted into that in Verilog model by converting the full-scale analog signal into an 11-bit digital code after uniform time sampling. The receiver waveform of transmission line is calculated by adding or subtracting the single-pulse response in Verilog model depending on the transmitting digital code values with appropriate time delay. The application of this work to a USB 2.0 high-speed PHY interface reduces the simulation time to less than three minutes with error less than 5% while the mixed-mode simulation takes more than two days for the same circuit.

Enhanced Fault Location Algorithm for Short Faults of Transmission Line (1회선 송전선로 단락사고의 개선된 고장점 표정기법)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.955-961
    • /
    • 2016
  • Fault location estimation is an important element for rapid recovery of power system when fault occur in transmission line. In order to calculate line impedance, most of fault location algorithm uses by measuring relaying waveform using DFT. So if there is a calculation error due to the influence of phasor by DC offset component, due to large vibration by line impedance computation, abnormal and non-operation of fault locator can be issue. It is very important to implement the robust fault location algorithm that is not affected by DC offset component. This paper describes an enhanced fault location algorithm based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any erstwhile information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced fault location algorithm uses DFT filter as well as the proposed DC offset filter. The behavior of the proposed fault location algorithm using off-line simulation has been verified by data about several fault conditions generated by the ATP simulation program.

A STUDY ON THE SELF-MATCHED LINE PULSE GENERATOR (자기정합 선로형 펄스 발생기에 관한 연구)

  • Paek, Yong-Hyun;Sohn, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.184-187
    • /
    • 1990
  • This paper presents the self-matched line pulse generator and the concerned principles on its operation and characteristics are mentioned. The circuit consists of a charged transmission line and a high speed switch, and it generates a square wave pulse with the very fast rise time. The generated waveform depends on the load resistance. As the load resistance is infinite, a single rectangular wave pulse is generated and its efficiency is nearly unity.

  • PDF

Effects of Coupling Resistor Resistance Discrepancy from Characteristic Impedance on Discriminating Characteristics of Super Wide-Band FM Line Discriminator (전송선형 초광대역 FM변별기에서 결합 저항기의 오차가 미치는 영향)

  • 이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.4
    • /
    • pp.1-5
    • /
    • 1970
  • This presents the way in shich the input impedance, and the output waveform of the line discriminator are influenced by a discrepancy of less than $\pm$10% in the coupling resistor resistance from the optium value(Characteristic impedance of the transmission line used in the line discriminator)

  • PDF

Design of an Underwater Target Simulator (수중표적 시뮬레이터설계)

  • 조내현;예윤해;정연모
    • Journal of the Korea Society for Simulation
    • /
    • v.12 no.4
    • /
    • pp.17-24
    • /
    • 2003
  • In this paper, we propose a model that simulates the reflective waveform from underwater objects by means of Doppler effect, highlight and elongation phenomenon. Also, this paper presents a hardware Implementation of simulation model with the input and output parameters. The underwater target simulator consists of transducer, receiver, transmitter and control parts. According to the experimental results of the simulator, it carried out the performances of real target in response to transmission signal.

  • PDF

Timing Analysis of Discontinuous RC Interconnect Lines

  • Kim, Tae-Hoon;Song, Young-Doo;Eo, Yung-Seon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • In this paper, discontinuous interconnect lines are modeled as a cascaded line composed of many uniform interconnect lines. The system functions of respective uniform interconnect lines are determined, followed by its time domain response. Since the time domain response expression is a transcendental form, the waveform expression is reconfigured as an approximated linear expression. The proposed model has less than 2% error in the delay estimation.

Effect Analysis of MW Transmission System for Strategic Unit Using Adaptive Modulation (적응변조 적용 전략제대 MW전송시스템 효과 분석)

  • Lim, Young-Gab;Youn, Jong-Taek;Choi, Young-Min;Kim, Young-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.3
    • /
    • pp.412-419
    • /
    • 2020
  • The strategic unit communication infrastructure for military command, communications requires a dualized network structure of various communication methods, considering the direction of development, strategic unit and line characteristic. It has been pointed out that MicroWave, which is typical of wireless systems, is inefficient because it operates only with existing technologies. Therefore, it is necessary to analyze the structure, efficiency of the MW transmission system and its effects. It is difficult to transfer efficiently considering wireless environment due to a fixed type of access structure in the existing MW transmission system. Adaptive modulation allows improvement, but with traditional access structures and fixed bandwidth, there is a limit. Following the transmission performance improvement technique considering availability and link distance in the previous study, this paper presented improved packetized MW transmission system structure and variable bandwidth transmission in consideration of adaptive modulation based variable transmission waveform, bandwidth and distance, and performed the analysis in view of the strategic unit and command control circuit.