• Title/Summary/Keyword: Total Harmonic Distortion

Search Result 416, Processing Time 0.046 seconds

Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM (6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF

New Generalized PWM Schemes for Multilevel Inverters Providing Zero Common-Mode Voltage and Low Current Distortion

  • Nguyen, Nho-Van;Nguyen, Tam-Khanh Tu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.907-921
    • /
    • 2019
  • This paper presents two advanced hybrid pulse-width modulation (PWM) strategies for multilevel inverters (MLIs) that provide both common-mode voltage (CMV) elimination and current ripple reduction. The first PWM utilizes sequences that apply one switching state at the double ends of a half-carrier cycle. The second PWM combines the advantages of the former and an existing four-state PWM. Analyses of the harmonic characteristics of the two groups of switching sequences based on a general switching voltage model are carried out, and algorithms to optimize the current ripple are proposed. These methods are simple and can be implemented online for general n-level inverters. Using a three-level NPC inverter and a five-level CHB inverter, good performances in terms of the root mean square current ripple are obtained with the proposed PWM schemes as indicated through improved harmonic distortion factors when compared to existing schemes in almost the entire region of the modulation index. This also leads to a significant reduction in the current total harmonic distortion. Simulation and experimental results are provided to verify the effectiveness of the proposed PWM methods.

Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator (풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향)

  • Rho, Sang-Pil;Park, Jung-Seok;Lee, Young-Gil;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

Efficient Hybrid Carrier Based Space Vector Modulation for a Cascaded Multilevel Inverter

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.277-284
    • /
    • 2010
  • This paper presents a novel hybrid carrier based space vector modulation for cascaded multilevel inverters. The proposed technique inherits the properties of carrier based space vector modulation and the fundamental frequency modulation strategy. The main characteristic of this modulation are the reduction of power loss, and improved harmonic performance. The carrier based space vector modulation algorithm is implemented with a TMS320F2407 digital signal processor. A Xilinx Complex Programmable Logic Device is used to develop the hybrid PWM control algorithm and it is integrated with a digital signal processor for hybrid carrier based space vector PWM generation. The inverter offers less weighted total harmonic distortion and it operates with equal electrostatic and electromagnetic stress among the power devices. The feasibility of the proposed technique is verified by spectral analysis, simulation, and experimental results.

A Study on the Power Supply Condition in the Railway Substation with Operating HSR350x (한국형 고속열차 주행에 따른 전철변전소 전력공급 상태에 관한 연구)

  • Im, Yong-Chan;Lee, Tae-Hyung;Han, Young-Jae;Park, Choon-Soo;Kim, Ki-Hwan;Sin, Myung-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.495-498
    • /
    • 2008
  • PCC(Point of Common Coupling) is measured by waveform in power system. Analyzing their frequency, it is possible to get various indices such as THD(Total Harmonic Distortion), TDD(Total Demand Distortion), and VF(Voltage Flicker), and then the harmonic can be evaluated from them. In this paper, the harmonic effect on the power supply which is generated by the vehicle is presented by comparing harmonics with the substation and the vehicle.

  • PDF

Converter Utilization Ratio Enhancement in the THD Optimization of Cascaded H-Bridge 7-level Inverters

  • Khamooshi, Reza;Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.173-181
    • /
    • 2016
  • In this paper, a new technique for harmonic optimization in cascaded H-bridge 7-level inverters is proposed. The suggested strategy is based on minimizing an objective function which simultaneously optimizes the converter utilization and Total Harmonic Distortion (THD). The Switch Utilization Ratio (SUR) is formulized for both the phase and line-line voltages of a 7-level inverter and is considered in the final objective functions. Based upon the SUR formula, utilization ratio enhancement will reduce the value of feeding DC links, which improves the efficiency and lifetime of the circuit components due to lower voltage stresses and losses. In order to achieve more effective solution in different modulation indices, it is assumed that the DC sources can be altered. Experimental validation is presented based on a three-phase 7-level inverter prototype.

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

FPGA Implementation of Diode Clamped Multilevel Inverter for Speed Control of Induction Motor

  • Kuppuswamy, C.L.;Raghavendiran, T.A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.362-371
    • /
    • 2018
  • This work proposes FPGA implementation of Carrier Disposition PWM for closed loop seven level diode clamped multilevel inverter in speed control of induction motor. VLSI architecture for carrier Disposition have been introduced through which PWM signals are fed to the neutral point seven level diode clamped multilevel using which the speed of the induction motor is controlled. This proposed VLSI architecture makes the power circuit to work better with reduced stresses across the switches and a very low voltage and current total harmonic distortion (THD). The output voltages, currents, torque & speed characteristics for seven level neutral point diode clamped multilevel inverter for AC drive was studied. It has observed the proposed scheme introduces less distortion and harmonics. The results were validated using real time results.

Harmonic Elimination Method of Using Coupling Transformer in Twelve Pulse Inverter (12 펄스 인버터에서 결합변압기를 이용한 고조파 제거기법)

  • Jeong, Chang-Yong;Lee, Young-Woon;Choi, Kyu-Hyoung;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.613-615
    • /
    • 1996
  • Harmonic elimination method of using coupling transformer in twelve pulse inverter is presented for high power application. This method is using coupling transformer and PWM(pulse width modulation) switching and voltage source inverter. The object of proposed harmonic elimination method is obtained inverter output of low THD(Total Harmonic Distortion). The simulation results confirm the proposed harmonic elimination method.

  • PDF

Infuences of Harmonic Current on Electrical Characteristics of an Induction Motor (유도전동기의 전기적 특성에 미치는 고조파 전류의 영향)

  • Park Yang-Birm;Kim Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.67-72
    • /
    • 2005
  • This paper proposes the influences of harmonic current on electrical characteristics of an induction motor. Recently, a power system gets more worse as nonlinear load makes harmonics to affect energy lose of system and shorten lift of machines. In this paper, the electrical effect and THD(Total Harmonic Distortion) of harmonic current to an induction motor which is of great use in the industrial fields are measured and analyzed. A power conversion equipment(inverter) is installed to produce harmonics and variable reactors are installed to reduce the harmonics having an effect on the input terminal. Then the effects of the reactors are measured and analyzed. Also average voltage, current, power and 110 by harmonics are analyzed. The results show that Inn is increased by increasing load of the induction motor and installing reactors. And the harmonics affecting the input terminal are decreased by increasing reactor 3[mH] to 6[mH], however, average power of the induction motor is decreased. Therefore, it is very important that reactors should be carefully installed considering the merits and demerits resulting from the installation of reactors.