• 제목/요약/키워드: Surface plasmon resonance imaging

검색결과 19건 처리시간 0.02초

영상 소자를 사용하지 않는 새로운 표면 플라즈몬 공명 센서 (A novel surface plasmon resonance sensor without using imaging devices)

  • 이승기
    • 센서학회지
    • /
    • 제15권5호
    • /
    • pp.347-351
    • /
    • 2006
  • A novel surface plasmon resonance sensor, which can measure 2-dimensional array of immobilized ligands without using imaging devices such as CCD, has been proposed. Regular surface plasmon resonance can be directly used due to the insertion of additional layers with different thickness, on which each ligands are immobilized. Surface plasmon resonance signals are separated depending on the thickness of additional layers. The possibility of multi-sensing capability of the proposed surface plasmon resonance sensor has been verified by the modeling that is based on Fresnel reflection model.

Development and evaluation of surface plasmon resonance imaging for the detection of antibodies against classical swine fever virus in swine

  • Cho, Ho-Seong;Lee, Tae-Uk;Park, Nam-Yong
    • 한국동물위생학회지
    • /
    • 제30권2호
    • /
    • pp.205-209
    • /
    • 2007
  • A protein chip based on surface plasmon resonance (SPR) imaging was developed for measuring classical swine fever virus (CSFV) antibody using a recombinant gp55 protein as an antigen. The diagnostic potential of SPR imaging for detecting antibodies to the CSFV gp55 protein was compared with that of a enzyme -linked immunosorbent assay (ELISA) using 70 pig sera. There was a strong positive correlation between the SPR imaging and ELISA (n=70, r=0.916, p<0.01). Therefore, the SPR imaging, which is a label-free and high-through put method, is expected to be a valuable tool in the serodiagnosis of CSFV.

표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발 (Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging)

  • 정찬호;이형주;최창경;이형순;이성혁
    • 한국분무공학회지
    • /
    • 제26권4호
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.

부가층의 두께 차이를 이용한 표면플라즈몬공명 멀티센싱 (Surface Plasmon Resonance Multisensing Using Thickness Difference of Additional Layer)

  • 김영규;오명환;이승기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권10호
    • /
    • pp.492-498
    • /
    • 2006
  • A novel surface plasmon resonance(SPR) multisensing method, which does not require imaging apparatus such as CCD, has been proposed and implemented experimentally. The proposed method is based on the multichannel SPR and the separation of signals by use of additional layers whose thickness is controlled. SPR signals are influenced by the thickness of sensing layer as well as the optical condition of sensing surface. As the SPR signals from different ligands are usually positioned closely, the reflected light from sensing surface does not provide us with the clear differences of resonance signal depending on the kinds of ligands. It was found from our experiments that SPR signals from each ligand that is located on the additional layer with different thickness can be separated clearly enough to identify various signals from different ligands. Proposed method with theoretical design and simulation has been verified experimentally by using $SiO_2$ thin film layer as additional layer.

Development of serodiagnostic surface plasmon resonance imaging assay for the detection of antibodies to porcine circovirus type 2

  • Park, Chul;Kim, Bum-Seok;Kim, Yong-Hwan;Cho, Ho-Seong
    • 한국동물위생학회지
    • /
    • 제34권1호
    • /
    • pp.1-4
    • /
    • 2011
  • A surface plasmon resonance imaging (SPRI) assay was developed for measuring porcine circovirus type 2 (PCV2) antibody using a recombinant capsid protein as an antigen. The diagnostic potential of SPRI for detecting antibodies to the PCV2 capsid protein was compared with that of a conventional enzyme-linked immunosorbent assay (ELISA) using 70 pig serum samples taken from 6 pig farms. There was a strong positive correlation between the SPRI and ELISA (n = 70, r = 0.911, P<0.01). Therefore, this recombinant capsid protein can be used as an antigen for serological studies, and the SPRI, a label-free and high-throughput method, is expected to be a valuable tool in the serodiagnosis of PCV2 infection.

Surface Plasmon Resonance Imaging Analysis of Hexahistidine-tagged Protein on the Gold Thin Film Coated with a Calix Crown Derivative

  • Chung, Bong-Hyun;Baek, Seung-Hak;Shin, Yong-Beom;Kim, Min-Gon;Ro, Hyeon-Su;Kim, Eun-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권2호
    • /
    • pp.143-146
    • /
    • 2004
  • A surface plasmon resonance (SPR) imaging system was constructed and used to detect the hexahistidine-ubiquitin-tagged human parathyroid hormone fragment (His$\sub$6/-Ub-hPTHF(1-34)) expressed in Escherichia coli. The hexahistidine-specific antibody was immobilized on a thin gold film coated with ProLinker$\^$TM/ B, a novel calixcrown derivative with a bifunctional coupling property that permits efficient immobilizaton of capture proteins on solid matrices. The soluble and insoluble fractions of an E. coli cell lysate were spotted onto the antibody-coated gold chip, which was then washed with buffer (pH 7.4) solution and dried. SPR imaging measurements were carried out to detect the expressed His$\sub$6/-Ub-hPTHF(1-34). There was no discernible protein image in the uninduced cell lysate, indicating that non-specific binding of contaminant proteins did not occur on the gold chip surface. It is expected that the approach used here to detect affinity-tagged recombinant proteins using an SPR imaging technique could be used as a powerful tool for the analyses of a number of proteins in a high-throughput mode.

전사인자 저해제 통한 미백제 탐색용 단백질 칩 제작 (Manufacturing Protein-DNA Chip for Depigmenting Agent Screening)

  • 한정선;곽은영;이향복;신정현;백승학;정봉현;김은기
    • 대한화장품학회지
    • /
    • 제30권4호
    • /
    • pp.479-483
    • /
    • 2004
  • MITF는 미백관련 유전자의 대표적인 조절 인자 단백질로서 미백관련 유전자의 E-box와의 결합정도를 단백질 칩을 이용하여 측정하였다. 융합 단백질 형태의 MITF를 유리 칩에 고정시켰고 E-box를 포함하는 DNA oligomer가 결합하는 것을 확인하였다. 형광법, SPR (surface plasmon resonance), SPRi (surface plasmon resonance imaging)방법 중 형광법이 가장 효과적이었으며, DNA 저해제를 사용시 결합이 감소하는 것을 확인하였다. 이 결과 MITF를 이용한 미백원료의 고속스크리닝(HTS)의 가능성을 보여주었다.

표면 플라즈몬 현미경을 이용한 자기조립 단분자막의 이미징 (Imaging of self-assembled monolayers by surface plasmon microscope)

  • 표현봉;신용범;윤현철;양해식;김윤태
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.97-102
    • /
    • 2003
  • 이차원 표면 플라즈몬의 공명 흡수와 포토 마스크를 이용하여 11-MUA(11-Mercaptoundecanoic acid)와 11-MUOH(11-Mercaptoundecanol) 둥으로 이루어진 자기조립 단분자막(Self-Assembled Monolayer; SAM)의 다채널 영상을 얻었다. 통상의 Photoresist를 이용한 리토그래피 대신에 Thiol bonding의 광산화를 이용하여 패터닝 과정을 줄이고, 백색광 및 대역통과 필터(λ$_{0}$=633nm)를 이용하여 입사광으로써 레이저를 사용할 때 나타나는 간섭무늬를 줄였다. 이로부터 나타나는 이차원 영상의 명암을 정량적으로 보정하면 수 나노미터(nm) 두께의 변화를 측정할 수 있다. 또한 표면 플라즈몬 공명법은 국소화된 근접장 (소산장)을 이용하는 방법으로서, 통상 많이 이용되는 형광법 등에서 나타나는 광탈색(Photobleaching)이나 소광(Quenching) 현상이 없이 시료의 처리가 간단하고, 영상 신호의 시간에 따른 변화가 극히 적으며, 실시간으로 신호의 변화를 측정할 수 있다는 장점이 있다.

Critical Enhancement of Photothermal Effect by Integrated Nanocomposites of Gold Nanorods and Iron Oxide on Graphene Oxide

  • Yun, Kum-Hee;Seo, Sun-Hwa;Kim, Bo-Mi;Joe, Ara;Han, Hyo-Won;Kim, Jong-Young;Jang, Eue-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2795-2799
    • /
    • 2013
  • Irradiation of gold nanorods (GNRs) with laser light corresponding to the longitudinal surface plasmon oscillation results in rapid conversion of electromagnetic energy into heat, a phenomenon commonly known as the photothermal effect of GNRs. Herein, we propose a facile strategy for increasing the photothermal conversion efficiency of GNRs by integration to form graphene oxide (GO) nanocomposites. Moreover, conjugation of iron oxide (IO) with the GO-GNR nanohybrid allowed magnetic enrichment at a specific target site and the separated GO-IO-GNR assembly was rapidly heated by laser irradiation. The present GO-IO-GNR nanocomposites hold great promise for application in various biomedical fields, including surface enhanced Raman spectroscopy imaging, photoacoustic tomography imaging, magnetic resonance imaging, and photothermal cancer therapy.