• 제목/요약/키워드: Steel rebar

검색결과 342건 처리시간 0.022초

The Effects of Cement Alkalinity upon the Pore Water Alkalinity and the Chloride Threshold Level of Reinforcing Steel in Concrete

  • ;;김기준
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.549-555
    • /
    • 2004
  • Cement of three alkalinities (equivalent alkalinities of 0.36,0.52 and 0.97) was employed in fabricating a set of classical G109 type specimens. To-date, these have been subjected to a one week wet-one week dry cyclic pending using 15 w/o NaCl solution. At the end of the dry period, potential and macro-cell current were measured to indicate whether the top reinforcing steel was in the passive or active state. Once this bar became active, the specimen was autopsied and the extent of corrosion was documented. Subsequent to visual inspection, concrete powder samples were collected from the upper region of the top rebar trace; and at a certain times concrete cores were taken from non-reinforced specimens. Using these, determinations were made of (1) critical chloride concentration for corrosion initiation ($Cl_{th}^-$), (2) effective chloride diffusion coefficient ($D_e$), and (3) pore water alkalinity ($[OH^-]$). The pore water alkalinity was strongly related to the alkali content of cement that was used in the mix. The chloride concentration, ($Cl^-$), was greater at active than at passive sites, presumably as a consequence of electro migration and accumulation of these species at active site subsequent to corrosion initiation. Accordingly, ($Cl^-$) at passive sites was considered indicative of the threshold concentration fur corrosion initiation. The $Cl_{th}^-$ was increased with increasing Time-to-corrosion ($T_i$). Consequently, the HA(High Alkalinity) specimens exhibited the highest $Cl_{th}^-$ and the NA(Normal Alkalinity) was the least. This range exceeds what has previously been reported in North America. In addition, the effective diffusion coefficient, $D_e$, was about 40 percent lower for concrete prepared with the HA cement compared to the NA and LA(Low Alkalinity) ones.

CT형강 전단연결재가 적용된 합성형 PHC벽체파일-하부슬래브 연결부 성능에 관한 실험적 연구 (An Experimental Study on Structural Capacity of Joint Between Composite PHC Wall Pile and Bottom Slab with CT Shear Connector)

  • 마호성;원정훈;이종구
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.531-541
    • /
    • 2013
  • 본 연구에서는 합성형 PHC 벽체파일의 CT형강 전단연결재가 벽체파일과 하부 슬래브와의 연결부에서 인장력에 저항하는 앵커의 성능을 갖는지 직접 인발실험을 통해 분석하였다. 다양한 실물 크기 실험체들의 파괴형상과 하중-변위 곡선으로부터 CT형강의 인발파괴를 방지하기 위해서는 CT형강 복부 홀에 관통철근을 배치하여 강도를 증가시켜야 함을 알 수 있다. 관통철근이 설치된 다양한 단면의 실험체들을 대상으로 지지점 거리를 변화시켜 파괴형상과 극한강도를 분석한 결과, CT형강의 인발파괴 전에 벽체파일 자체의 콘크리트 인장파괴가 모든 실험체에서 발생하므로 적용된 CT형강 전단연결재는 벽체파일과 하부 슬래브 연결부의 발생 인장력에 대해 충분히 저항할 수 있다.

GFRP 보강근의 부착파괴면 (Bond Failure Surface of Glass Fiber Reinforced Polymer Bars)

  • 이정윤;이종구;김태영;박지선;박영환
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.383-391
    • /
    • 2008
  • 이 연구에서는 콘크리트의 압축강도가 증가함에 따라서 변화하는 GFRP 보강근의 부착 특성을 조사하였다. 실험에서는 3종류의 콘크리트에 배근된 27개의 보강근의 부착응력-부착미끌림 관계를 측정하였다. 하중가력이 종료한 후에 실험체를 절단하여 고강도콘크리트가 GFRP 보강근의 부착에 미치는 영향을 살펴보았다. 실험 결과에 의하면 GFRP 보강근의 부착파괴면은 철근과 상이하게 2개의 면으로 구분되었다. 파괴면은 콘크리트와 외피 사이의 파괴면과 외피와 섬유보강근 사이의 파괴면으로 구분 할 수 있었다. 이와 같은 GFRP 보강근의 부착파괴면은 콘크리트의 압축강도가 증가함에 따라서 콘크리트의 접착력과 외피의 접착력의 상호관계에 따라서 달라졌다. GFRP 보강근의 부착강도는 콘크리트의 압축강도가 증가함에 따라서 증가하였지만, 증가 비율은 철근의 부착강도보다 낮았다.

비파괴 철근탐사의 주요 영향인자에 관한 실험적 연구 (An Experimental Study on Principal Factors for Non-destructive Test of Detecting Steel bars)

  • 오광진;김종호;이종우;이윤향
    • 한국재난관리표준학회지
    • /
    • 제3권1호
    • /
    • pp.25-32
    • /
    • 2010
  • 콘크리트 구조물 내의 철근탐사는 구조물의 상태를 평가하는 중요한 단계중의 하나이다. 본 연구에서는 비파괴 철근탐사기 중 전자기유도법과 전자파레이터법의 측정 정밀도 제고를 위한 제반 실험을 수행하였다. 시험에 크기가 1,000 mm(길이)${\times}300mm$(폭)이고 철근직경, 피복두께가 각기 다른 4개의 콘크리트 시험체를 이용하였다. 실험은 90일간의 공기중 건조 후와 3, 24, 48시간 및 28일간의 침수 후 실시되었다. 실험결과, 전자기유도법의 경우, 철근직경이 커짐에 따라 오차가 증가하는 것으로 나타났으며, 전자파레이더법의 경우에는 실제 피복두께에 맞는 비유전율에 따라 측정하여 깊은 심도의 경우에도 신뢰도가 우수한 것으로 나타났다. 수분함량이 3.6~5.5%로 증가함에 따라서 콘크리트 시험체의 비유전율도 증가하는 경향을 보이는 것으로 나타났다. 따라서 수분함량이 비유저율을 결정하는데 주요한 영향인자 중의 하나라는 것을 확인할 수 있었으며, 수분함유량에 따른 유전상수 산출식을 도출, 제시하였다.

  • PDF

해양환경 중 Zn-mesh를 적용한 콘크리트 슬랩의 음극방식 특성 (Cathodic Protection of Reinforced Concrete Slab with Zn-Mesh in Marine Environment)

  • 김기준;정진아;이우철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1065-1068
    • /
    • 2008
  • 해상교량은 바다에 노출되기 때문에 많은 경우 본래의 설계수명을 다하지 못하고 조기에 열화된다. 이러한 콘크리트 열화는 다공성인 콘크리트 내부에 염분이 침투함으로써 철근부식을 야기하고, 부식된 철근은 보통 $6{\sim}10$배까지 부피가 팽창하면서 콘크리트에 균열을 일으키고 결국 탈락(박리)으로 이어진다. 이와 같은 철근부식과 균열발생의 가속화는 구조물의 심각한 손상과 궁극적으로 붕괴까지 이어질 수 있다. 따라서 이러한 피해를 막기 위해서는 콘크리트 내 철근부식의 정확한 이해가 필요하며, 부식발생의 정량화에 의한 예측은 물론 적절한 방식법을 적용해야한다. 음극방식법은 비교적 최근에 개발된 철근콘크리트 구조물의 방식법 중 하나이며 요즈음도 해외 여러 나라에서 이에 대한 방식시스템 연구가 활발하다. 본 연구에서는 해상교량이나 항만부두 구조물의 상판부에 대한 예비실험 성격으로 슬랩 시험편(40cm ${\ast}$ 30cm ${\ast}$ 18cm)을 채택하였다. 시험환경은 15% 염분과 온도 $40^{\circ}C$의 가속화된 해양환경이었으며, 시험 기간 동안 주기적인 건습 반복을 실시하였다. 방식시험편은 음극방식 기술의 하나인 Zn-mesh에 의한 희생양극식을 채택하였다. 연구내용으로는 음극방식에 의한 방식성능을 관찰하였으며 신설구조물과 보수구조물에 대한 방식 효과를 비교하였다.

  • PDF

Axial compressive behavior of concrete-encased CFST stub columns with open composite stirrups

  • Ke, Xiaojun;Ding, Wen;Liao, Dingguo
    • Advances in concrete construction
    • /
    • 제12권5호
    • /
    • pp.399-409
    • /
    • 2021
  • The existing method to improve the coordination performance of the inner and outer parts of concrete-encased concrete-filled steel tube (CFST) composite columns by increasing the volume-stirrup ratio causes difficulties in construction due to over-dense stirrups. Thus, this paper proposes an open polygonal composite stirrup with high strength and high ductility CRB600H reinforced rebar, and seventeen specimens were constructed, and their axial compressive performance was tested. The main parameters considered were the volume-stirrup ratio, the steel tube size, the stirrup type and the stirrup strength. The test results indicated: For the specimens restrained by open octagonal composite stirrups, compared with the specimen of 0.5% volume-stirrup ratio, the compressive bearing capacity increased by 14.6%, 15.7% and 21.5% for volume-stirrup ratio of 0.73%, 1.07% and 1.61%, respectively. For the specimens restrained by open composite rectangle stirrups, compared with the specimen of 0.79% volume-stirrup ratio, the compressive bearing capacity increased by 7.5%, 6.1%, and -1.4% for volume-stirrup ratio of 1.12%, 1.58% and 2.24%, respectively. The restraint ability and the bearing capacity of the octagonal composite stirrup are better than other stirrup types. The specimens equipped with open polygonal composite stirrup not only had a higher ductility than those with the traditional closed-loop stirrup, but they also had a higher axial bearing capacity than those with an HPB300 strength grades stirrup. Therefore, the open composite stirrup can be used in practical engineering. A new calculation method was proposed based on the stress-strain models for confined concrete under different restrain conditions, and the predicted value was close to the experimental value.

유공강판 전단연결재의 인발저항성능 평가 (Pull-out Resistance Capacity Evaluation of Perfobond Rib Shear Connector)

  • 김영호;구현본
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.853-859
    • /
    • 2008
  • 본 연구에서는 유공강판 전단연결재를 강관말뚝머리 연결부의 결합용 구조 요소로 활용하기 위한 연구의 일환으로 유공강판 전단연결재의 홀 형상, 홀 직경, 홀 관통철근, 매입깊이 등에 따른 구조적 성능 및 거동 특성을 실험적으로 규명하였으며, 그 결과 유공강판 전단연결재가 충분한 인발저항성능을 확보하기 위해서는 콘크리트 다웰 효과가 충분히 발현될 수 있도록 확보가능한 만큼의 다수의 홀을 가공 배치하되, 각 홀의 직경은 전단연결재 높이의 절반 정도임과 동시에 관통철근 배근 후에도 콘크리트의 완전한 충전이 가능할 만큼의 홀 내 여유 공간을 충분히 확보하는 것이 바람직하며, 아울러 유공강판 전단연결재가 강관말뚝머리 연결부의 결합용 구조 요소로서의 제기능을 발휘할 수 있도록 충분한 정착성능을 확보할 필요가 있다.

칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링 (EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment)

  • 김제경;기성훈;이정재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.1-8
    • /
    • 2019
  • 본 연구는 시멘트 모르타르 속에 매입된 철근이 3wt.% NaCl 전해질 수용액에 8시간 침지 및 대기 중에서 16시간 건조가 반복되는 환경에 있을 때 교류 임피던스법을 이용하여, 10kHz에서 용액저항, 10mHz에서 전하이동저항을 측정하여, 그 값의 차이로부터 분극저항을 계산하여 부식속도를 측정하였다. 부식속도를 제어하기 위해 포화 Ca(OH)2 용액에서 일정시간 전착하여, 그 효과를 관찰하였다. 철근의 부식속도는 용존산소의 확산속도 증가에 의해, 침지보다는 건조 환경에서 가속되었으며, 이것은 모르타르 두께가 얇을수록 명확히 측정되었다. 침지 및 건조 반복횟수가 증가함에 따로, 철근의 부식속도는 부동태에서 Low-middle 상태로 가속되었으며, 그 기준은 다수의 연구자들이 사용한 기준을 사용하였다. 이 기준에 의해 철근의 부식속도가 Low-middle 상태가 되면, 포화 Ca(OH)2 용액에서 -10 uA/㎠ 전류밀도를 사용하여 철근에 전착을 진행하고, 5일간 건조시킨 후, 3wt.% NaCl 용액에서 침지-건조 반복실험을 다시 진행하면서, 부식속도를 측정하였다. 측정결과, 모르타르의 두께가 얇은 경우, 부식속도의 감소를 명확히 관찰하였다. 또한, 전착에 의한 철근의 부식속도 감소는 침지상태에서 보다 철근이 건조과정에 놓일 때, 더욱 크게 측정되었다. 전착처리에 따라 칼슘은 철근표면과 모르타르 계면에 존재하는 Porous rust layer의 void를 메우는 것으로 보인다. 시험체가 건조과정에 놓일 때, 철근표면에 형성된 다공질의 녹층속에 농축된 Ca2+가 침지과정보다 쉽게 CO32-와 결합되어, CaCO3가 형성됨으로서 철근의 부식속도를 더욱 감소시킨 것으로 생각된다.

UV 폭로 및 동결융해 시험을 거친 FRP Hybrid Bar의 인장거동 평가 (Evaluation of Tension Behavior in FRP Hybrid Bar Affected by UV Exposure and Freezing/Thawing Tests)

  • 윤용식;박재성;박기태;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제5권2호
    • /
    • pp.130-136
    • /
    • 2017
  • 본 연구에서는 UV 폭로 및 동결융해 환경이 FRP Hybrid Bar의 인장거동 및 표면 열화에 미치는 영향을 평가하기 위해 FRP Hybrid Bar를 대상으로 UV 폭로 및 동결융해 시험을 실시하였다. FRP Hybrid Bar의 경우 UV 폭로 및 동결융해 180cycle 시험 전/후 외관적인 열화가 거의 발생하지 않았다. 또한 FRP Hybrid Bar의 주요 장점 중 하나인 인장경화특성은 동결융해 시험을 거친 이후에도 유지되었는데, 이는 UV 폭로시험을 거친 FRP Hybrid Bar에도 유효하게 평가되었다. UV 폭로시험을 거친 FRP Hybrid Bar는 일반 FRP Hybrid Bar와 거의 비슷한 인장거동을 나타내었으며, 동결융해 180cycle의 진행에도 불구하고 일반철근, FRP Hybrid Bar, UV 폭로를 거친 FRP Hybrid Bar의 인장거동은 큰 변화를 나타내지 않았다. 본 연구에서는 UV 폭로 및 동결융해 환경이 FRP Hybrid Bar의 외관 및 인장 특성에 큰 영향을 미치지 못하는 것으로 판단되지만, 충격에 따른 규사코팅의 박락은 콘크리트와의 부착력에 영향을 미치므로 이에 대한 고려가 필요하다.

외부철판이 사용된 DH Beam의 휨거동에 대한 실험 및 비선형해석 (Experiment and Nonlinear Analysis of DH Beams with Steel Form)

  • 문정호;오영훈
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.171-179
    • /
    • 2014
  • 이 연구는 DH beam의 구조성능을 평가하는 것을 목적으로 하였다. DH beam을 사용하는 DH 공법은 얇은 철판을 성형하여 거푸집 및 구조적 역할을 할 수 있는 철판을 철근과 함께 공장에서 선조립하여 현장으로 반입하여 콘크리트를 타설하는 공법이다. 이 때 DH 판이 거푸집 역할 뿐 아니라 휨강도에 기여할 것으로 여겨져서 이 연구에서는 DH 판의 휨강도 기여도를 평가하고자 하였다. 총 5개의 실험체를 대상으로 실험 및 해석적 연구를 수행하였다. 실험체는 2개의 정모멘트 실험체, 2개의 부모멘트 실험체, 그리고 1개의 RC 실험체로 구성되었다. RC 실험체는 DH beam과 비교를 목적으로 제작하였다. DH beam에 대한 실험 결과는 휨강도를 산정하는 설계식 그리고 RC 실험체에 대한 실험 결과 등과 비교를 통하여 DH beam은 철판이 항복하면서 충분히 휨강도에 기여하고 있음을 알 수 있었다. 그리고 비선형 구조해석에서는 두 개의 실험체에 대하여 DH 판이 있는 경우와 없는 경우를 대상으로 휨강도, 콘크리트의 주인장변형률, 그리고 철근의 응력을 비교하였으며, 해석에서도 DH 판이 휨강도에 충분히 기여함을 알 수 있었다. 이상과 같은 실험 및 해석적 연구의 결과 DH beam의 철판은 콘크리트와 합성단면을 형성하여 충분한 휨강도를 갖는 것으로 보였다.