As a new system of steel pipe pile cap reinforcement, the application of perforated flat bar bolted to the steel pipe pile head was suggested for the improvement of structural performance of footing structure. This study investigates the structural characteristics of perforated flat bar shear connectors according to shape and diameter of hole, number of rebars passing through the hole and the depth of settlement. The result shows several requirements to ensure sufficient pull-out resistance and ductility such as that the hole diameter excluding diameter of rebar should exceed the size of aggregates; the hole should be perforated with diameter as the half of plate height; and the adequate depth of settlement should be ensured for the optimal performance.

본 연구에서는 유공강판 전단연결재를 강관말뚝머리 연결부의 결합용 구조 요소로 활용하기 위한 연구의 일환으로 유공강판 전단연결재의 홀 형상, 홀 직경, 홀 관통철근, 매입깊이 등에 따른 구조적 성능 및 거동 특성을 실험적으로 규명하였으며, 그 결과 유공강판 전단연결재가 충분한 인발저항성능을 확보하기 위해서는 콘크리트 다웰 효과가 충분히 발현될 수 있도록 확보가능한 만큼의 다수의 홀을 가공 배치하되, 각 홀의 직경은 전단연결재 높이의 절반 정도임과 동시에 관통철근 배근 후에도 콘크리트의 완전한 충전이 가능할 만큼의 홀 내 여유 공간을 충분히 확보하는 것이 바람직하며, 아울러 유공강판 전단연결재가 강관말뚝머리 연결부의 결합용 구조 요소로서의 제기능을 발휘할 수 있도록 충분한 정착성능을 확보할 필요가 있다.

Keywords

References

  1. 구현본, 김형열, 김정호(2005) 유공판재형 전단연결재의 성능실험연구, 한국구조물진단학회 봄학술발표회 논문집, 한국구조물진단학회, pp. 3-8.
  2. 김형열, 구현본(2006) 강-콘크리트 합성 바닥판용 전단연결재의 합성 거동 연구, 대한토목학회 논문집, 대한토목학회, 제26권, 제1A호, pp. 91-97.
  3. 안진희, 김상효, 구현본, 강균희(2007) Perfobond Rib 전단연결재의 잔류강도 및 잔류강도 평가, 대한토목학회 논문집, 대한토목학회, 제27권, 제2A호, pp. 237-245.
  4. 정철헌, 이흥수, 박종면, 김영호(2004) 합성작용을 위한 새로운 Perfobond 전단연결재, 대한토목학회 논문집, 대한토목학회, 제24권, 제3A호, pp. 525-532.
  5. 정철헌, 이흥수, 유성근, 최외호(2005) 원형강관 거더와 콘크리트바닥판 사이 형 perfobond 리브 전단연결재의 실험적 연구, 대한토목학회 논문집, 대한토목학회, 제25권, 제1A호, pp. 1-12.
  6. 정철헌, 이흥수 (2005) 형 perforbond 리브 전단연결재의 전단강도 평가, 대한토목학회 논문집, 대한토목학회, 제25권, 제5A호, pp. 879-888.
  7. Leonhardt, F., Andra, W., Andram H.-P., and Harre, W. (1987) Neues Vorteihaftes Verbundmittel fur Stahlverbund-tragwerke mit Hoher Dauerfestigket, Betonund Stahlbetonbau.
  8. Machacek, J. and Studnicka, J. (2002) Perforated shear connectors, Steel and Composite Structures, Vol. 2, No. 1, pp. 51-66. https://doi.org/10.12989/scs.2002.2.1.051
  9. Oguejiofor, E.C. and Hosain, M.U. (1992) Behaviour of perfobond rib shear connectors in composite beams:full size test, Canadian Journal of Civil Engineering, Vol. 19, No. 2, pp 224-235. https://doi.org/10.1139/l92-028
  10. Oguejiofor, E.C. and Hosain, M.U. (1994) A paramatic study of perfobond rib shear connectors, Canadian Journal of Civil Engineering, Vol. 21, pp. 614-625. https://doi.org/10.1139/l94-063
  11. Oguejiofor, E.C. and Hosain, M.U. (1997) Numerical analysis of push-out specimens with perfobond rib connectors, Computers & Structures, Vol. 62, No. 4, pp. 617-624. https://doi.org/10.1016/S0045-7949(96)00270-2
  12. Sara, B.M. and Bahram, M.S. (2002) Perforbond shear connector for composite construction , Engineering Journal, First Quarter, pp. 2-12.
  13. Veldanda, M.R. and Hosain, M.U. (1992) Behavior of perfobond rib shear connectors : Push-out tests, Canadian Journal of Civil Engineering, Vol. 19, No. 1, pp. 1-10. https://doi.org/10.1139/l92-001
  14. Valente, I. and Cruz, P.J.S. (2004) Experimental analysis of perfobond shear connection between steel and lightweight concrete, Journal of Constructional Steel Research, Vol. 60, pp. 465-479. https://doi.org/10.1016/S0143-974X(03)00124-X
  15. Zellner, W. (1987) Recent designs of composite bridges and a new type of shear connectors. Proc. ASCE/IABSE Engineering Foundation Conference on Composite Construction. Henniker, N.H. pp. 240-252.