Evaluation of Tension Behavior in FRP Hybrid Bar Affected by UV Exposure and Freezing/Thawing Tests  

Yoon, Yong-Sik (Department of Civil Engineering, Hannam University)
Park, Jae-Sung (Department of Civil Engineering, Hannam University)
Park, Ki-Tae (Korea Institute of Civil Engineering and Building Technology)
Kwon, Seung-Jun (Department of Civil Engineering, Hannam University)
Publication Information
Journal of the Korean Recycled Construction Resources Institute / v.5, no.2, 2017 , pp. 130-136 More about this Journal
Abstract
The present work is for an evaluation of tension behavior and surface deterioration of FRP Hybrid Bar due to UV exposure and freezing/thawing(F/T) actions. For the work, FRP Hybrid Bar is subjected to UV exposure test, then F/T test is performed successively to 180 cycles. In FRP Hybrid Bar, no significant surface deterioration is evaluated after UV exposure. Tension hardening performance, a unique engineering advantage of FRP Hybrid Bar, is still maintained after F/T test. The performance in FRP Hybrid Bar exposed to UV is still effective. FRP Hybrid Bar exposed to UV have almost similar tension behavior of FRP Hybrid Bar without UV exposure. Although F/T cycles increase to 180, steel rebar, FRP Hybrid Bar, and FRP Hybrid Bar exposed to UV show no significant changes in tension behavior. In the work, UV exposure and F/T actions are evaluated to have little negative effect on surface deterioration and tensile performance in FRP Hybrid Bar, however spalling of silica coating due to impact should be considered since it affects bonding strength to outer concrete.
Keywords
Steel rebar; FRP Hybrid Bar; Tensile behavior; Freezing and thawing test; UV exposure test;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 ACI 440.1R-06. (2006). Guide for the Design and Construction of Structural Concrete Reinforce with FRP Bars, ACI Committee 440.
2 Al-Amoudi, O.S.B., Maslehuddin, M. (1993). The effect of chloride and sulfate ions on reinforcement corrosion. Cement and Concrete Research, 23(1), 139-146.   DOI
3 Broomfield, J.P. (1997). Corrosion of Steel in Concrete: Understanding, Investigation and Repair, E&FN, London, 1-15.
4 Cho, H.G., Yoo, D.H., Kang, H.G. (2008). Surface characteristic and tracking resistance of epoxy insulating materials against ultraviolet, Journal of the Korean Institute of Electrical and Electronic Material Engineers, 9, 495-496 [in Korean].
5 Choi, K.S., You, Y.C., Lee, H.S., Kim, K.H. (2006). Experimental study on freezing-thawing and warm-moisture resistance of FRP composites used in strengthening RC members, Journal of the Korea Concrete Institute, 18(1), 345-348 [in Korean].
6 Choi, S.J., Mun, J.M., Park, K.T., Park, C.W., Kwon, S.J. (2015). Characteristics of flexural capacity and ultrasonic in RC member with corroded steel and FRP hybrid bar, The Journal of the Korea Contents Association, 15(8), 397-407 [in Korean].   DOI
7 Dan, R., Liliana, R., Franica, M., Cristian-Dragos, V. (2012). Effect of UV radiation on some semi-interpenetrating polymer networks based on polyurethane and epoxy resin, Polymer Degradation and Stability, 97, 1261-1269.   DOI
8 KICT. (2013). Development of Enhancing Life Span Technology for Waterfront Structures using FRP Hybrid Bars, Korea Institute of Civil Engineering and Building Technology [in Korean].
9 KS F 2456. (2013). Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing, Korean Agency for Technology and Standards [in Korean].
10 KS M ISO 4892-2. (2012). Plastics-Methods of exposure to laboratory light sources-part 2:Xenon-arc sources, Korean Agency for Technology and Standards [in Korean].
11 Oh, B.H., Um, J.Y., Kwon, J.H. (1992). An experimental study on corrosion resistance of epoxy coated reinforcements, Journal of the Korea Concrete Institute, 4(4), 161-170 [in Korean].
12 Seo, D.W., Park, K.T., You, Y.J., Hwang, J.H. (2014). Evaluation for tensile performance of recently developed FRP hybrid bars, International Journal of Emerging Technology and Advanced Engineering, 4(6), 631-637.
13 Oh, K.S., Park, K.T., Kwon, S.J. (2016). Evaluation of anti-corrosion performance of FRP hybrid bar with notch on GGBFS concrete, Journal of the Korea Institute for Structural Maintenance and Inspection, 20(4), 51-58 [in Korean].   DOI
14 Ramirez, E., Gonzalez, J.A., Bautista, A. (1996). The protective efficiency of galvanizing against corrosion of steel in mortar and in $Ca(OH)_2$ saturated solutions containing chlorides, Cement and Concrete Research, 26(10), 1525-1536.   DOI
15 Sadegh, P.A., Changiz, D., Ali, K. (2015). Corrosion protection of the reinforcing steel in chloride-laden concrete environment through epoxy/polyaniline-camphorsulfonate nanocomposite coating. Corrosion Science, 90, 239-247.   DOI
16 Hearle, J.W.S., Grosberg, P., Backer, S. (1969). Structural Mechanics of Fibers, yarns and fabrics, Wiley-interscience, New York.
17 Seo, D.W., Park, K.T., You, Y.J., Kim, H.Y. (2013). Enhancement in elastic modulus of GFRP bars by material hybridization, Engineering, 5, 865-869.   DOI
18 Shin, S.W., Ahn, J.M., Han, B.S., Seo, D.W. (2006). Effects of reinforcement ratio on concrete beams reinforced with FRP re-bars, Journal of the Architectural Institute of Korea, 22(2), 19-26 [in Korean].
19 Song, T.H., Choi, K.S., You, Y.C., Kim, K.H. (2006). Experimental study on ultra-violet resistance of FRP composites used in strengthening RC members. Journal of the Korea Concrete Institute, 18(1), 333-336 [in Korean].
20 U. S. Department of Commerce. (1994). U. S. Industrial Outlook, Bernan Associates, U. S, 5-11.