Axial compressive behavior of concrete-encased CFST stub columns with open composite stirrups  

Ke, Xiaojun (College of Civil Engineering and Architecture, Guangxi University)
Ding, Wen (College of Civil Engineering and Architecture, Guangxi University)
Liao, Dingguo (College of Civil Engineering and Architecture, Guangxi University)
Publication Information
Advances in concrete construction / v.12, no.5, 2021 , pp. 399-409 More about this Journal
Abstract
The existing method to improve the coordination performance of the inner and outer parts of concrete-encased concrete-filled steel tube (CFST) composite columns by increasing the volume-stirrup ratio causes difficulties in construction due to over-dense stirrups. Thus, this paper proposes an open polygonal composite stirrup with high strength and high ductility CRB600H reinforced rebar, and seventeen specimens were constructed, and their axial compressive performance was tested. The main parameters considered were the volume-stirrup ratio, the steel tube size, the stirrup type and the stirrup strength. The test results indicated: For the specimens restrained by open octagonal composite stirrups, compared with the specimen of 0.5% volume-stirrup ratio, the compressive bearing capacity increased by 14.6%, 15.7% and 21.5% for volume-stirrup ratio of 0.73%, 1.07% and 1.61%, respectively. For the specimens restrained by open composite rectangle stirrups, compared with the specimen of 0.79% volume-stirrup ratio, the compressive bearing capacity increased by 7.5%, 6.1%, and -1.4% for volume-stirrup ratio of 1.12%, 1.58% and 2.24%, respectively. The restraint ability and the bearing capacity of the octagonal composite stirrup are better than other stirrup types. The specimens equipped with open polygonal composite stirrup not only had a higher ductility than those with the traditional closed-loop stirrup, but they also had a higher axial bearing capacity than those with an HPB300 strength grades stirrup. Therefore, the open composite stirrup can be used in practical engineering. A new calculation method was proposed based on the stress-strain models for confined concrete under different restrain conditions, and the predicted value was close to the experimental value.
Keywords
axial compression; CRB600H; composite column; concrete-filled steel tube; open polygonal composite stirrup;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 GB/T 50080 (2017), Standard for Test Method of Performance on Ordinary Fresh Concrete, China Architecture Building Press, Beijing, China.
2 Sun, L.Z., Wu, D.Y., Zhao, J.L., Yang, F. and Li, W. (2017), "Behavior of circular RC columns with two layers of spirals", KSCE J. Civil Eng., 21, 955-963. https://doi.org/10.1007/s12205-016-0928-0.   DOI
3 Wang. L.S. and Qian, J.R. (2004), "Experimental research on complete axial compressive stress-strain curve of high-strength concrete filled steel tubular columns", Build. Struct., 34(1), 11-19. https://doi.org/10.19701/j.jzjg.2004.01.003.   DOI
4 Qian, J., Cheng, L. and Zhou, D. (2002), "Behavior of axially loaded concrete columns confined with ordinary coops", J. Tsinghua Univ., 42(10), 1369-1373. https://doi.org/10.16511/j.cnki.qhdxxb.2002.10.024.   DOI
5 Hong, H.P., Huang, Y. Deng, L. and Bai, Y. (2019), "Axial capacity of steel tube-reinforced concrete stub columns", Eng. Struct., 183, 523-532. https://doi.org/10.1016/j.engstruct.2019.01.044.   DOI
6 Mander, J.B. and Priestley, M.J.N. (1988), "Observed stress-strain behavior of confined concrete", J. Struct. Eng., 114(8), 1827-1849. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1827).   DOI
7 Chen, Q.J., Cai, J. and Bradford, M.A. (2014), "Seismic behaviour of a through-beam connection between concrete-filled steel tubular columns and reinforced concrete beams", Eng. Struct., 80, 24-39. https://doi.org/10.1016/j.engstruct.2014.08.036.   DOI
8 Cusson, D. and Paultre, P. (1998), "High-strength concrete columns confined by rectangular ties", J. Struct. Eng., 120, 783-804. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:3(783).   DOI
9 Eurocode (2004), Design of Composite Steel and Concrete Structures Part1-1, General Rules-Structural Rules for Buildings, European Committee for Standardization, Brussels, Belgium.
10 Han, L.H. and An, Y.F. (2014), "Performance of concrete-encased CFST box stub columns under axial compression", J. Constr. Steel Res., 93, 62-76. https://doi.org/10.1016/j.jcsr.2013.10.019.   DOI
11 Hwang, S.K. and Yun, H.D. (2004), "Effects of transverse reinforcement on flexural behaviour of high-strength concrete columns", Eng. Struct., 26(1), 1-12. https://doi.org/10.1016/j.engstruct.2003.08.004.   DOI
12 Ji, X., Kang, H., Chen, X. and Qian, J. (2014), "Seismic behavior and strength capacity of steel tube-reinforced concrete composite columns", Earthq. Eng. Struct. Dyn., 43(4), 487-505. https://doi.org/10.1002/eqe.2354.   DOI
13 Liang, C.Y., Chen, C.C., Weng, C.C., Yin, Y.L. and Wang, J.C. (2014), "Axial compressive behavior of rectangle composite columns confined by multiple spirals", J. Constr. Steel Res., 103, 230-240. https://doi.org/10.1016/j.jcsr.2014.09.006   DOI
14 Cai, J., Pan, J., Su, H. and Lu, C., (2018), "Experimental study on the hysteretic behavior of ECC-encased CFST columns", Eng. Struct., 173, 107-121. https://doi.org/10.1016/j.engstruct.2018.06.095.   DOI
15 ACI318-11 (2011), Building Code Requirements for Structural Concrete and Commentary, American Concrete Institute, Detroit, USA.
16 AISC360-10 (2010), Specification for Structural Steel Buildings, American Institute of Steel Construction (AISC), Chicago, USA.
17 Cai, J., Pan, J. and Li, X. (2018), "Behavior of ECC-encased CFST columns under axial compression", Eng. Struct., 171, 1-9. https://doi.org/10.1016/j.engstruct.2018.05.090.   DOI
18 Zhang, J., Cai, R., Li, C. and Liu, X. (2020), "Seismic behavior of high-strength concrete columns reinforced with high-strength steel bars", Eng. Struct., 218, 110861. https://doi.org/10.1016/j.engstruct.2020.110861.   DOI
19 Cai, M., Ke, X. and Su, Y. (2020), "Axial compressive performance of RAC-encased RACFST composite columns", Eng. Struct., 210, 110393. https://doi.org/10.1016/j.engstruct.2020.110393   DOI
20 Candappa, D.P., Setunge, S. and Sanjayan, J.G. (1999), "Stress versus strain relationship of high strength concrete under high lateral confinement", Cement Concrete Res., 29(12), 1977-1982. https://doi.org/10.1016/S0008-8846(99)00219-7.   DOI
21 CECS458 (2016), Technical Specification for CRB600H High Ductility and High Strength Steel Bars, China Planning Press, Beijing, China.
22 JGJ95 (2011), Technical Specification for Concrete Structures with Cold-rolled Ribbed Steel Wires and Bars, China Architecture Building Press, Beijing, China.
23 Xu, L. and Liu, Y.B. (2013), "Concrete filled steel tube reinforced concrete (CFSTRC) columns subjected to iso-834 standard fire: experiment", Adv. Struct. Eng., 16(7), 1263-1282. https://doi.org/10.1260/1369-4332.16.7.1263.   DOI
24 Yang, F., Sun, L., Zhao, J., Wu, D. and Li, W. (2015), "Behavior of a novel circular HSC column with double high strength spirals", Adv. Struct. Eng., 18, 1371-1382. https://doi.org/10.1260/1369-4332.18.9.1371.   DOI
25 Chen, Y., Feng, J. and Yin, S. (2012), "Compressive behavior of reinforced concrete columns confined by multi-spiral hoops", Comput. Concrete, 9, 341-355. https://doi.org/10.12989/cac.2012.9.5.341   DOI
26 GB/T 228.1 (2010), Metallic Materials-tensile Testing-Part 1, Method of Test at Room Temperature (ISO 6892-1:2009, MOD).
27 Han, L.H., Wang, Z.B., Xu, W. and Tao, Z. (2016), "Behavior of concrete-encased CFST members under axial tension", J. Struct. Eng., 142, 04015149. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001422.   DOI
28 Li, Y.J., Han, L.H., Xu, W. and Tao, Z. (2015), "Circular concrete-encased concrete-filled steel tube (CFST) stub columns subjected to axial compression", Mag. Concrete. Res., 68(19), 1-16. https://doi.org/10.1680/jmacr.15.00359.   DOI
29 Li, Y., Li, G., Hou, C. and Zhang, W.J. (2019), "Long-term experimental behavior of concrete-encased CFST with preload on the inner CFST", J. Constr. Steel. Res., 155, 355-369. https://doi.org/10.1016/j.jcsr.2019.01.001.   DOI
30 Xue, J., Zhang, X., Ke, X. and Ma, L. (2019), "Seismic resistance capacity of steel reinforced high-strength concrete columns with rectangular spiral stirrups", Constr. Build Mater., 229, 116880. https://doi.org/10.1016/j.conbuildmat.2019.116880.   DOI
31 T/CECS188 (2019), Technical Specification for Steel Tube-reinforced Concrete Column Structure, China Architecture Building Press, Beijing, China.
32 Shi, Q., Wang, N., Tian, Y., Wang, P. and Li, K. (2013), "Study on stress-strain relationship of high-strength concrete confined with high-strength stirrups under axial compression", J. Build. Struct., 34(4), 144-151. https://doi.org/10.14006/j.jzjgxb.2013.04.014.   DOI
33 Zhou, X.H., Zheng, Z. and Dan, G. (2020), "Analysis and design of axially loaded square CFST columns with diagonal ribs", J. Constr. Steel Res., 167, 105848. https://doi.org/10.1016/j.jcsr.2019.105848.   DOI
34 Ma H., Li M. and Wang Q. (2019), "Experimental study on seismic performance of full-scale concrete-filled steel tube columns with openings in the steel tube wall", World Earthq. Eng., 35, 53-61. https://doi.org/CNKI:SUN:SJDC.0.2019-01-007.
35 Mander, J.A.B. and Priestley, M.J.N. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804).   DOI
36 Pooya, A., Yoshiharu, S. and Bing, L. (2018), "Drift capacity of high-strength concrete columns with mixed-grade longitudinal reinforcements", Adv. Struct. Eng., 22, 519-534. https://doi.org/10.1177/1369433218794270.   DOI