• Title/Summary/Keyword: Screen Door Effect

Search Result 16, Processing Time 0.028 seconds

Effect of Platform Screen Door on fire in the subway station (스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구)

  • Jang, Yong-Jun;Jung, Woo-Sung;Park, Won-Hee;Kim, Hag-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1337-1345
    • /
    • 2007
  • The present study is a basic investigation for systematically proceeding disaster prevention studying the effect of platform screen door in case of fire at the subway station. In the paper, the characteristics of screen door were surveyed and described. The fully closed platform screen door and the island type of subway station were employed for simulation-study. Numerical simulations of fire driven flow at the subway station with platform screen door were performed with commercial fire CFD code. For analyzing of the effect of platform screen door, the fire simulations with and without the platform screen door were compared. For the fire location, the one is located on the platform and the other case on the railway. The Ultrafast model was taken as fire growth scenario. The maximum heat release rate was 10MW. The propagated time of the heat and smoke to stairs was within 4 minute when the fire is located on the platform. However the heat and smoke propagation was block off by screen door when the fire is located on the railway.

  • PDF

Development of Optimum Design Technology of Platform Screen Door Systems for the Environment Improvement and Disaster Prevention of Urban Railway (도시철도 환경개선 및 방재를 위한 스크린도어시스템 최적설계기술 개발)

  • Kim, Jung-Yup
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.84-87
    • /
    • 2008
  • In order to maximize the effect of installing screen door system while to minimize the problems in an initial stage of introduction, it is strongly required to research an optimum installation solution in connection with ventilation and disaster prevention system alongside with safety structure analysis of screen door in respect to train-induced wind, as well as to develop the criteria for the operation after the installation. This paper presents the results of study to develop the optimum design technology in urban railway equipped with platform screen door systems.

  • PDF

Investigation and Evaluation of Noise Level of the Busan Subway (부산 지하철 소음도 조사 및 평가)

  • Lee, Chang-Myung;Jung, Jin-Guk;Jung, Jin-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.243-250
    • /
    • 2011
  • Noise levels of the three subway lines of Busan city have been investigated. Averaged cabin noise of the train has been measured during the train trip for each station. It has been measured with separation of day time (9:00~18:00) and night time (18:00~22:00) measurements but there was no big difference on the measured data. Repeating for the measured data has been confirmed with twice measurements in May and June 2010. Several noise effects to the subway noise levels of Busan are explained. Those are screen door effect, rail road surface condition, subway train type and curvature of railway. Among three subway lines of Busan city, the line 2 is relatively noisy and its reasons are studied. It has been shown that the screen door effect is 10 dB(A) and S shape of sharp curve contributes in high noise level.

Actual Noise Condition of the Subway Station in Gwang-ju City (광주광역시 지하철 소음실태 조사연구)

  • Kim, Heung-Sik;Park, Gi-Pyo;Shin, Seung-Hun;Lee, Min-Tae;Moon, Gyeong-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.934-937
    • /
    • 2004
  • The purpose of this study is to present a fundamental data to get the noise reduction method of subway station in Gwang-ju city. Subway noise level measurement and questionnaire on the satisfaction of sound condition were carried out. The results show that the noise level of the subway station and the noise reduction effect installed by screen door is over 10 dB(A).

  • PDF

The Removal Effect of Fine Particles Applied Platform Screen Door in Seoul Subway Station (지하철 역사 승강장의 PSD 설치에 의한 미세먼지 감소 효과)

  • Sohn, Jong-Ryeul;Jung, Young-Rim;Park, Hyun-Hee;Oh, Youn-Hee;Choi, Won;Kim, Soon-Geun
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.60-68
    • /
    • 2009
  • The most principal approach to improve indoor air quality(IAQ) of subway was to examine the fine particulate(PM-10) from the emission sources. Therefore, this study was carried on the investigation the fine particulate for comparison with the removal efficiency of PM-10 in divided the PSD(Platform Screen Door) and Non-PSD subway station from July, 2007 to May 2008. In the monitoring results, the range of PM-10 concentration of Non-PSD station was $44.6{\sim}116.5{\mu}g/m^3$ and the range of PM-10 concentration of PSD station was $23.9{\sim}81.1{\mu}g/m^3$. And then the range of PM-2.5 concentration of Non-PSD station was $17.4-56.6{\mu}g/m^3$, and then the range of PM-2.5 concentration of PSD station was $17.9{\sim}34.4{\mu}g/m^3$. In comparison with the results of the PSD and Non-PSD subway station, we found that the PM-10 removal efficiency of PSD was 30-40%. In conclusion, the PSD will be applied the effective facilities of decreasing PM-10 in subway station in Korea.

The Technical Suggestion for Implementing Animated PSD Ads : Focused on Seoul Metro Line2 (동적 PSD광고 구현을 위한 기술적 제안 : 수도권 지하철 2호선을 중심으로)

  • Kim, Kyoung-Joo;Kim, Suk-Rae
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.381-391
    • /
    • 2018
  • The purpose of this research is to propose a new method of PSD(Platform Screen Door) ads using animated image for efficiency, based on the theoretical background that moving objects have a stronger visual attractiveness effect than static objects. For this, we analyze the relationship between the screen door and the train, then derive the positional and visual elements which help to create efficient animated images. Based on this analysis, we made an example and applied into 3D program to confirm the implementation process of the animated PSD ads. As the result, the research shows that it is possible to produce a new type of PSD ads that can show dynamic visual effects and can give diversity to the PSD advertising media through the combination of the images using time difference.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Heat and Fluid Flow Characteristics in Subway Station Platform with Consideration of Pressure Drop between Screen Doors and Stair Passages (스크린 도어와 계단 통로 사이 압력 강하량에 따른 지하철 승강장 내부 열유동 특성)

  • Yoon, Jung-Bae;Kim, Seok-Wan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.21-28
    • /
    • 2006
  • In the present study, the analysis on heat and fluid flow in subway station platform is carried out by considering the pressure drop between screen doors and stair passages. To investigate the effect on the characteristics of heat and fluid flow of pressure drop, Numerical simulation is applied. The present results show a better cooling condition, in the case of without pressure drop.

  • PDF

Kinematic Envelope Effect Analysis of the Urban Transit EMU According to PSD Installation (PSD 설치에 따른 도시철도차량의 Kinematic Envelope 영향 분석)

  • Chung, Jong-Duk;Pyun, Jang-Sik;Cho, Hui-Je;Hong, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1779-1784
    • /
    • 2010
  • Since PSD(Platform Screen Door) is set up at many subway stations, its design related to a safety becomes gradually important. Especially the intereference check with a running railway vehicle is the most important of performance indices. This study proposes a dynamic analysis models for the railway vehicle and rail. Some design parameters are considered in the models to find a correlation to the performance.

  • PDF