• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.032 seconds

Measurement of the Natural Radiation Dose in the Ski Field (Focusing on the Gyeonggi Province area) (스키장의 자연방사선량 측정(경기도 지역을 중심으로))

  • Jung, Hongmoon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.117-122
    • /
    • 2017
  • With the increase in leisure life, the population of ski resorts is rapidly increasing. The activity at the ski resort is likely to receive a direct chance of natural sunlight or space ray. Because it is located in the mountains where altitude exists. As a general rule, it is widely known that the higher the elevation rate, the more increasing the natural radiation dose. However, the natural radiation dose rate for the ski slopes has not been reported yet. Various ski resorts exist in Korea, but this study had chose 4 ski resorts to measure the natural dose of natural radiation. As a result, the natural radiation dose for the ski slope was measured at a relatively high dose of ordinary living areas. However, the level of natural radiation dose was not worrisome. It is recommended to wear ski wear or goggles to minimize natural radiation exposure at the ski slopes.

Determination of the Effective Energy of X-Ray Beam Using Optically Stimulated Luminescent nanoDot Dosimeters (광자극형광나노닷선량계를 사용한 X선 빔의 유효에너지 결정)

  • Kim, Jongeon;Lee, Sanghun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.375-379
    • /
    • 2015
  • The purpose of this study is to determine the effective energy of a polyenegetic X-ray beam. The half value layer(HVL) of aluminum for 80 kVp X-ray beam was measured by using optically stimulated luminescent nanoDot dosimeters(OSLnDs). The linear attenuation coefficient(${\mu}$) was calculated using the measured HVL. And the mass attenuation coefficient(${\mu}/{\rho}$) was obtained by dividing the linear attenuation coefficient by the density(${\rho}$) of aluminum. The effective energy($E_{eff}$) of the obtained mass attenuation coefficient was determined using data of the X-ray mass attenuation coefficients for photon energies of aluminum given by National Institute of Standards and Technology(NIST). As a result, the HVL value is 2.262 mmAl. The ${\mu}$ value is $3.06cm^{-1}$. The ${\mu}/{\rho}$ value is $1.114cm^2/g$. And the $E_{eff}$ value was determined at 29.79 keV.

A STUDY ON SECONDARY IMAGES IN PANORAMIC RADIOGRAPH (파노라마방사선사진에 있어서 이차상에 관한 연구)

  • Cho Dai Hee;Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.81-87
    • /
    • 1984
  • This study was performed to observe the secondary images and to analyse the relationships between the primary and secondary images in panoramic radiograph. Using the Moritta's Panex-EC panoramic x-ray machine and the human dry skull, the author analysed 17 radiographs which were selected from 65 radiographs of the dry skull that attached the radiopaque materials, and the attached regions of the radiopaque materials were the normal anatomical structures which were important and selected as a regions for the evaluation of the secondary images effectively. The results were as follows; 1. The cervical vertebrae showed three images. The midline image was the most distorted and less clear, and bilateral images were slightly superimposed over the posterior border of the mandibular ramus. 2. In mandible, the secondary image of the posterior border of the ramus was superimposed on the opposite ramus region, and this image was elongated from the anterior border of the ramus to the lateral side of the posterior border of the ramus. The secondary image of the condyle was observed on the upper area of the coronoid process, the sigmoid notch and the condyle in opposite side. 3. In maxilla, the posterior region of the hard palate showed the secondary image on the lower part of the nasal cavity and the medial wall of the maxillary sinus. 4. The primary images of the occipital condyle and the mastoid process appeared on the same region, and only the secondary image of the occipital condyle was observed symmetrically on the opposite side with similar shape to the primary one. 5. In the cranial base, the anatomical structures of the midsagittal portions like a inferior border of the frontal sinus, sella turcica, inferior borderr of the sphenoid sinus and inferior border of the posterior part of the occipital bone showed the simillar shape between the primary and secondary images symmetrically. 6. The petrous portion of the temporal bone showed the secondary image on the lateral side of the sella-turcica, and the secondary images of the posterior border of lesser wing, superior border of greater wing of the sphenoid bone and posterior border were observed on the anterior-superior and inferior region of the sella-turcica.

  • PDF

CLINICO-RADIOLOGICAL STUDY OF RADICULAR CYST OF THE JAW (악골 치근단 낭종의 임상 방사선학적 연구)

  • Choi Sung Youn;Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.111-120
    • /
    • 1984
  • The author analyzed clinically and radiologically 319 radicular cysts which were proven histologically in Infirmary College of Dentistry Yonsei University and Seoul National University Hospital from 1965 to 1983, and which occurred in 167 males and 139 females between the ages of 6 and 70. This analysis was undertaken to discover the frequency and distribution of the radicular cysts with regard to the age and sex, the chief complaints of the patients, the regions, the radiographical appearances, the tooth changes, and the anatomical structures involved by the lesions. The obtained results were as follows: 1. The most frequently involved age group for the radicular cysts was the third decade of the patients, and the greatest number 69.9 per cent occurred between the ages of 11 and 40 years. The statistical analysis did not show any significant difference between male and female (P>0.05) 2. The frequently involved region for the radicular cysts was orderly the maxillary anterior region (44.9 per cent), the mandibular anterior region (15.9 per cent), the maxillary premolar region (14.8 per cent), and the mandibular premolar region (11.0 per cent). The maxillo-mandibular ratio of the radicular cysts was about 7:3. The statistical analysis did not show any significant difference between right and left sides (P>0.05). 3. The greatest number was 92.2 per cent, which were involved in apical portions of the radicular cysts, 88.7 per cent of the radicular cysts were found in the round shapes which were oval and elliptical, and 66.8 per cent of the radicular cysts were observed with the completely hyperostotic borders. 4. The radicular cysts caused the root resorption in 55.2 per cent and the migration of the involved tooth or teeth in 23.5 per cent respectively.

  • PDF

A ROENTGENOGRAPHIC CEPHALOMETRIC STUDY OF CONDYLAR HEAD ON THE SUBMENTOVERTEX CEPHALOGRAM (두부축방향방사선규격사진에 있어서 하악과두의 두부방사선계측학적 연구)

  • Baek Hong Woo;Ryu Young Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.12 no.1
    • /
    • pp.49-56
    • /
    • 1982
  • The purpose of this study was to observe the anatomic variation of condylar head and the positional relationship between condylar head and other anatomic structures of head by means of cephalometry using the submentovertex cephalogram from each person in centric occlusion for producing a good quality of temporomandibular joint radiograph. The 100 submentovertex cephalograms of 100 Korean adults consisted of 50 females ranged from 20 to 24 years age and 50 males ranged from 22 to 30 years age, were studied and analyzed statistically. The results were as follows; 1. The mean of the horizontal angulation of condylar head to the transmeatal line (EE-LA) was 18.5° (S.D. 7.9°), and all measurements that indicate the horizontal angulation of condylar head showed considerable differences among individuals. 2. In the comparison of male vs. female in the measurements, statistically significant differences were found in the majority of measurement items, and with exception of R-LA and LA-LA, the rest of these measurements were larger in male than in female. 3. In the comparison of left vs. right in the measurements, statistically significant differences were found in the majority of measurement items, and with exception of PC-CC, the rest of these measurements were larger in right than in left. As above, because the majority of measurements that involve the horizontal angulation of condylar head varied among individuals, between male and female, and between left and right, the condition of various temporomandibular joint radiography should be determined by means of cephalometry using the submentovertex cephalogram for producing the accurate radiographic image of temporomandibular joint.

  • PDF

Effectiveness Evaluation of Scanogram Using Longbone Detector (Longbone 검출기를 이용한 Scanogram의 유효성 평가)

  • Jang, Su-han;Heo, Ji-eun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.235-242
    • /
    • 2020
  • Scanogram is that combine several practical images into one image to observation. So it is an important consideration in many clinical situation such as iliac measurement, leg alignment measurement and Scoliosis. Currently, scanogram examinations are mainly conducted for children and elderly patients. In this study, in order to apply the longbone detector to children or elderly patients who are difficult to cooperate with, we compared the longbone detector from D equipment with the G equipment discovery 656 Puls equipment in reproducibility of images, distribution of irradiation dose, scattering dose, irradiation time and image acquisition time. D equipment took more than twice as much time as G equipment. The scattered dose generated about 50% more G equipment than D equipment. In the whole spine scanogram and the measurement length of the lower leg, D equipment was also measured longer than G equipment. However, both methods did not show much difference from the CT scanogram, so there was no problem in measurement. The height of the thyroid radiation dose of G equipment was produced more radiation than D equipment. However, the longbone detector deviated from the x-ray center line relative to the tube rotation method, and was measured lower by the directionality of the measuring instrument, so that the error could not be corrected. In the conclusion of study, using the longbone detector is excellent for applying to children or elderly patients to reduce scattering dose. However, using CR may be useful to normal patients. Because, the image quality may deteriorate due to an imbalance of dose difference in thickness depending on the body part. So, it is useful to using a compensation filter or tube rotation method when we take a whole spine scanogram.

A Statistical compare analysis of bone mineral density of lumbar spine and femur, Risk Factors for Osteoporosis in the women of pre, postmenopausal (폐경전,후 여성에서 골다공증의 위험요인과 요추와 대퇴골의 골밀도 비교분석)

  • Lee, Won-Jeong;Ki, No-Weon
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.227-234
    • /
    • 2005
  • - Objective Osteoporosis is one of the characteristic adult diseases, high prevalence, many complications, easy fracture, important health problem. this study, compared analysis BMD data of the lumbar spine and femur - Methods For the 100 female patients,

  • PDF

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series (위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.889-894
    • /
    • 2019
  • Upper gastrointestinal series is an examination that uses X-rays. It is important to defend against exposure to radiation during upper gastrointestinal examination because the organs, such as thyroid gland, lens, breasts, and gonads, with relatively high biological sensitivity to radiation are distributed on the examination area. We have made a whole body phantom that can change the depth of organs. radiation dose of eye, thyroid gland, breast and gonads were measured by the same procedure as the actual upper gastrointestinal examination. When performed only fluoroscopy the mean dose reduction of lens, thyroid gland, breast and gonads was 62.2%. The mean dose reduction of lens, thyroid gland, breast and gonads was 59.0% when both fluoroscopy and spot shoot were performed. Therefore, when performed upper gastrointestinal examination it was confirmed that shielding of the lens, thyroid gland, breast and gonads was effective in decreasing the exposure dose. The manufactured human phantom can be used in measuring radiation dose for deep organ because it can adjust the height corresponding to the organs located in the human body.