A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

The Relationship between Use of Sunblocks and Dry Eye (자외선 차단제 사용과 건성안의 연관성)

  • Yoo, Hyun;Lee, Eun-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.347-353
    • /
    • 2016
  • Dry eye symptoms can occur by various environmental exposure. This study aimed to investigate the relationship between eye symptom especially dry eye and sunblocks. Study subjects were total 30 (28 male, 2 female) and NIBUT, McMonnies dry eye questionnaire, subjective questionnaire were performed. NIBUT after rubbing sunblocks was decreased compared to that of not-rubbing. Sunblocks C showed the largest difference of NIBUT value and was chosen most uncomfortable sunblocks in subjective questionnaire. Half of the subjects (15) felt eyes discomfort after rubbing sunblocks and showed larger McMonnies dry eye questionnaire score than other subjects. The same result was founded about dry eye suspect criterion. Both showed borderline significant relation(p=0.049, p=0.051). This study suggested that sunblock could cause damage to the eyes and related to dry eye when rubbing sunblock around eyes. Because digital environmental factors could affect stimulus and modify the eyes, a convergence study will be required for additional research.

Change of Refractive Error after Watching Smart-phone under Low Intensity of Illumination (낮은 조도에서 스마트폰 시청 후 시력 변화)

  • Kim, Bong-Hwan;Han, Sun-Hee;Kwon, Sang-Jin;Kim, Do-Hun;Kim, Mi-Sung;Jeong, Hyun-Seung;Kim, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.105-109
    • /
    • 2014
  • Purpose: To compare the change of visual acuity and NIBUT after watching smart-phone in 1 hour under low intensity of illumination. Methods: 50 subjects (male 22, female 28) aged 20's years old ($20.7{\pm}2.4$ years) who do not have eye disease and have a good eye condition were participated for this study. Objective refraction, corrected distance visual acuity and NIBUT were measured before and after watching smart-phone (Galaxy 2, Samsung, KOREA) under low intensity of illumination (0 lx.) Objective refraction was carried out using auto-chart project (CP-1000, Dongyang, Korea), phoropter (VT-20, Dongyang, Korea) and auto refractor-keratometer (MRK-3100, Huvitz, Korea). Results: Refractive error was changed from $-3.20{\pm}2.00$ D to $-3.38{\pm}2.00$ D (p=0.006) and corrected distance visual acuity was changed from $0.93{\pm}0.08$ to $0.91{\pm}0.10$ (p=0.000) and NIBUT was changed from $10.48{\pm}7.00$ seconds to $10.29{\pm}6.47$ seconds (p=0.761) before and after watching smart-phone under low intensity of illumination. Conclusions: Continuous watching smart-phone under low intensity of illumination lead to temporal change of distance visual acuity and suitable rest may reduce the influence of distance visual acuity and tear safety.

Comparative Analysis of Questionnaires for Dry Eye Screening Test (안구건조증 설문지의 일치도 연구)

  • Kim, Da-Young;Lee, Sun-Haeng;Cho, Hyun-Gug;Kim, Kun-Kyu;Kim, Ha-Na;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.499-504
    • /
    • 2014
  • Purpose: This study is to evaluate the accuracy of dry eye screening test by comparing coincidences between three types of questionnaires and objective tests. Methods: 90 adults were classified into the normal and dry eye groups using evaluations of three types of questionnaires (SPEED, OSDI, TERTC-DEQ) and objective tests (NIBUT, Schirmer test). Coincidences-between the results of objective tests and questionnaires were compared and analyzed for dry eye diagnosis. Results: Coincidences between NIBUT test and each questionnaire were 83.3% by SPEED, 77.8% by OSDI and 72.3% by TERTC-DEQ, respectively. Concordance by SPEED was highest among three types of questionnaire. Coincidences between the Schirmer test and each questionnaire were 57.8% by SPEED, 58.9% by OSDI and 73.3% by TERTC-DEQ, respectively, thus coincidence by TERTC was higher than by others. But coincidences by Schirmer test were generally lower than those by NIBUT test. Conclusions: SPEED questionnaire showed the highest concordance with objective test as compared with others. Therefore, SPEED is expected to be used usefully to diagnose dry eyes.

Reference values for selected dry eye tests in normal Beagle dogs: a pilot study

  • Kim, Youngsam;Kang, Seonmi;Kim, Sunhyo;Shim, Jaeho;Go, Seokmin;Seo, Kangmoon
    • Journal of Veterinary Science
    • /
    • v.23 no.1
    • /
    • pp.10.1-10.12
    • /
    • 2022
  • Background: Dry eye disease (DED) cannot be diagnosed by a single test because it is a multifactorial disorder of the ocular surface. Although studies on various dry eye tests (DETs) in dogs have been reported, standard criteria have not been established except for the Schirmer tear test 1 (STT-1). Objectives: To establish reference values for DETs in dogs with normal STT-1 values (≥ 15 mm/min) and to analyze the correlation between DETs. Methods: The STT-1 was performed in 10 healthy Beagle dogs (20 eyes). After 20 min, interferometry (IF) for estimating the lipid layer thickness (LLT) of the tear film, tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and meibomian gland loss rate of the upper eyelid (MGLRU) and lower eyelid (MGLRL), were measured using an ocular surface analyzer. Results: Mean values for STT-1, TMH, and NIBUT were as follows: 21.7 ± 3.4 mm/min, 0.41 ± 0.21 mm, and 19.1 ± 9.5 sec, respectively. The most frequent LLT range, measured by IF, was 30-80 nm (11 eyes), followed by 80 nm (5 eyes) and 80-140 nm (4 eyes). MGLRU ≤ 25% was measured in 11 eyes and 26%-50% in 9 eyes; MGLRL ≤ 25% in 8 eyes and 26%-50% in 12 eyes. Besides positive correlation between TMH and NIBUT (P = 0.038), there were no significant associations between DETs. Conclusions: Data obtained in this study provided normative references that could be useful for diagnosing DED and for further research into correlation between DETs in dogs with DED.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

The Effect of Artificial Tear Components on Tear Film Stability of Dry Eyes in the Early Stage of Soft Contact Lenses Wear (소프트콘택트렌즈를 착용한 건성안의 착용초기 눈물막 안정성에 인공눈물 성분 조성이 미치는 영향)

  • Kim, So Ra;Lim, Jung A;Jung, Ji Hye;Byun, Hyun Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.191-201
    • /
    • 2016
  • Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

A Study on distribution of Dry Eye and Diagnosis Methods (건성안의 분포와 진단 방법에 대한 연구)

  • Ryu, Geun Chang;Park, Hyun Ju;Kim, Jae Min;Lee, Seung A;Ra, Myung Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.91-98
    • /
    • 2000
  • To investigate the distribution of dry eye and to accept diagnosis methods of dry eye in ophthalmic shop, this study was performed on 81 persons(male : 49, female : 32). 1. We divided two group for diagnosing dry eye by dry eye screening questionnaire : one was dry eye symptom group(49.3%) and the other was non-dry eye symptom group(50.7%). 2. Non-invasive break-up time(NIBUT) which was measured by using Tear $scope^{(R)}$ (Killer. co)was longer than invasive break-up time(IBUT). 3. A blink rate in dry eye symptom group(10%) was measured lesser than 10 cycle/min, in non-dry eye symptom group(14.9%). 4. In shirmer test there were lesser than 10mm/5min in dry eye symptom group(67.5%), in non-dry eye symptom group(39%). 5. Cornea and conjunctival staining by rose bengal represented Mild 25%, medium 36.25%, extreme 38.75% in dry eye symptom group. Non-dry eye symptom group was showed Mild 19.51%, medium 14.63%, extreme 12.19%. 6. These results showed that the patient showed dry eye symptom in 3 items of eye examination was 22.5%, 4 items 25%, 5 items 30%, 6 items 15%.