Abstract
Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.
Keywords
Artificial tear; Dry eyes; Soft contact lens; Non-invasive tear film break-up time; Blink rate; Subjective symptoms;
Citations & Related Records
Times Cited By KSCI : 12  (Citation Analysis)
연도 인용수 순위
1 Kim WJ, Kim HS, Kim MS. Current trends in the recognition and treatment of dry eye: A survey of ophthalmologists. J Korean Ophthalmol Soc. 2007;48(12):1614-1622.   DOI
2 Calonge M. The treatment of dry eye. Surv Ophthalmol. 2001;45(2):S227-S239.   DOI
3 Kim EC, Joo CK. Efficacy of vitamin A-containing lubricant in dry eye syndrome evaluated by impression cytology. J Korean Ophthalmol Soc. 2008;49(11):1729-1736.   DOI
4 Kim EC, Choi JS, Joo CK. A comparison of vitamin A and cyclosporine A 0.05% eye drops for treatment of dry eye syndrome. Am J Ophthalmol. 2009;147(2):206-213.   DOI
5 Jang SR, Yun IS, Lim HS, Kook KH. Comparison of wettability for ocular prosthesis depending on different kinds of artificial tear eye drops. J Korean Ophthalmol Soc. 2014;55(12):1745-1751.   DOI
6 Murube J, Paterson A, Murube E. Classification of Artificial Tears: I: Composition and Properties. Adv Exp Med Biol. 1998;438:693-704.
7 Lee SE, Kim SR, Park M. Oxygen permeability of soft contact lenses in different pH, osmolality and buffering solution. Int J Ophthalmol. 2015;8(5):1037-1042.
8 Korea Pharmaceutical Information Center. Drug Information. Eyedew ophthalmic solution. http://www.health.kr/drug_info/basedrug/show_detail.asp?idx=42409(7 May 2016).
9 Lee SH, Hyung SM, Koh SH, Park M, Kim SR. The effect of circle contact lens on the stability of tear film. J Korean Ophthalmic Opt Soc. 2015;20(2):125-131.   DOI
10 Park M, Kang SY, Chang JI, Han AR, Kim SR. changes in subjective discomfort, blinking rate, lens centration and the light transmittance of lens induced by exceeding use of daily disposable circle contact lenses in dry eyes. J Korean Ophthalmic Opt Soc. 2014;19(2):153-162.   DOI
11 Kim SR, Park SH, Joo SO, Lee HR, Park M. A comparison of the movements of circle contact lens and soft contact lens with identical material on cornea. J Korean Ophthalmic Opt Soc. 2012;17(1):27-35.
12 Subbaraman LN, Glasier MA, Varikooty J, Srinivasan S, Jones L. Protein deposition and symptoms with daily wear etafilcon lenses. Optom Vis Sci. 2012;89(10):1450-1459.   DOI
13 Lee BJ, Hong JH, Jung D, Park M. A study on the confidence of dry eye diagnosis methods. J Korean Ophthalmic Opt Soc. 2008;13(1):15-20.
14 Schnetler R, Gillan WDH, Koorsen G. Immunological and antimicrobial molecules in human tears: a review and preliminary report. S Afr Optom. 2012;71(3):123-132.
15 Nicolaides N, Kaitaranta JK, Rawdah TN, Macy JI, Boswell FM 3rd, Smith RE. Meibomian gland studies:comparison of steer and human lipid. Invest Ophthalmol Vis Sci. 1981;20(4):522-536.
16 Bron AJ, Tiffany JM, Gouveia SM, Yokoi N, Voon LW. Functional aspects of the tear film lipid layer. Exp Eye Res. 2004;78(3):347-360.   DOI
17 Goto E, Endo K, Suzuki A, Fujikura Y, Matsumoto Y, Tsubota K. Tear evaporation dynamics in normal subjects and subjects with obstructive meibomian gland dysfunction. Invest Ophthalmol Vis Sci. 2003;44(2):533-539.   DOI
18 Gilbard JP, Farris RL. Tear osmolarity and ocular surface disease in keratoconjunctivitis sicca. Arch Ophthalmol. 1979;97(9):1642-1646.   DOI
19 Pflugfelder SC. Management and therapy of dry eye disease: report of the management and therapy subcommittee of the international dry eye workshop. Ocul Surf. 2007;5(2):163-178.   DOI
20 Kim SR, Kang BH, Jung IP, Park M. The change in the parameters of silicone hydrogel lens and objective/subjective symptoms induced by repetitive dryness of lens. J Korean Ophthalmic Opt Soc. 2012;17(4):381-388.
21 Park M, Lee YN, Kang KE, Lee MH. Changes of lens morphology and TBUT by dehydration of soft contact lens. J Korean Ophthalmic Opt Soc. 2008;13(2):1-7.
22 Park M, Yang JH, Kim SM, Park SI, Park SH, Kim SR. Changes in centration of contact lenses on cornea and blink rate associated with overusage of disposable lenses. J Korean Ophthalmic Opt Soc. 2008;13(4):51-58.
23 Kim JH, Song JS, Hyon JY, Chung SK, Kim TJ. A survey of contact lens-related complications in Korea: the Korean contact lens study society. J Korean Ophthalmol Soc. 2014;55(1):20-31.   DOI
24 Kim TH, Min GR, Sung AY. Study on the contact lenses wear status of university students. J Korean Ophthalmic Opt Soc. 2005;10(2):151-157.
25 Kim JS, Cho KJ, Song JS. Influences of computer works on blink rate and ocular dryness in adolescents. J Korean Ophthalmol Soc. 2007;48(11):1466-1472.   DOI
26 Kim DJ, Cha JW, Park MC, Lee WJ. The influence of temperature and relative humidity variation on the dry eye for using smart phone. J Korean Vis Sci. 2014;16(3):397-407.