The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes

정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이

  • Jung, Da I (Department of Visual Optics, Seoul National University of Science and Technology) ;
  • Lee, Heum Sook (Department of Food Science and Technology, Seoul National University of Science and Technology) ;
  • Kim, So Ra (Department of Visual Optics, Seoul National University of Science and Technology) ;
  • Park, Mijung (Department of Visual Optics, Seoul National University of Science and Technology)
  • 정다이 (서울과학기술대학교 안경광학과) ;
  • 이흠숙 (서울과학기술대학교 식품공학과) ;
  • 김소라 (서울과학기술대학교 안경광학과) ;
  • 박미정 (서울과학기술대학교 안경광학과)
  • Received : 2010.10.29
  • Accepted : 2010.12.18
  • Published : 2010.12.31

Abstract

Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

목적: 정상안과 건성안에 소프트렌즈를 각각 얼라인먼트(alignment) 피팅 또는 스팁(steep) 피팅하였을 때 비침입성 눈물막 파괴 시간(non-invasive tear break-up time, NIBUT)에는 어떠한 차이를 보이는지 알아보고자 하였다. 방법: 건성안 검사방법에 따라 정상안군과 건성안군으로 분류된 20~30대 남녀 40안에 polymacon 재질의 소프트렌즈를 얼라인먼트 피팅 혹은 스팁 피팅으로 착용시킨 후 렌즈 착용 전, 착용 직후 및 눈물층이 안정화 되었을 때의 NIBUT를 측정 비교하였다. 결과: 얼라인먼트 피팅시 눈물층이 안정화되었을 때는 건성안군의 평균 NIBUT가 정상안군의 값과 차이가 없었으나, 렌즈를 착용한 직후는 통계적으로 유의한 차이가 있었다. 스팁한 피팅을 한 경우에 는 렌즈 착용 직후 건성안에서의 평균 NIBUT가 정상안에 비해 통계적으로 유의한 감소를 보였다. 또한, 스팁 피팅하였을 때는 건성안의 65%가 4초 이하의 NIBUT을 나타내어 얼라인먼트 피팅하였을 때보다 30% 가량 그 수가 증가하였다. 건성안에 스팁 피팅을 하였을 때에는 눈물층이 안정화된 후에도 NIBUT가 감소하는 경향을 나타내었다. 결론: 본 연구를 통하여 건성안의 경우 소프트렌즈의 착용시 눈물막과의 상호관계가 정상안과는 상이함을 확인할 수 있었으며, 따라서 건성안에 콘택트렌즈를 피팅할 때에는 렌즈 착용으로 인하여 야기되어질 수 있는 불안정한 눈물막 상태가 충분히 고려되어져야 할 것으로 생각되어진다.

Keywords

References

  1. 김대수, 박미정, "콘택트렌즈물리", 초판, 북스힐, 서울, pp. 92-97(2007).
  2. 박용복, 김수복, "콘택트렌즈 교실 ", 초판, 전파과학사, 서울, pp. 218-223(1996).
  3. 김태훈, 민경록, 성아영, "대학생들의 콘택트렌즈 착용 실태에 관한 연구", 대한안광학회지, 10(2):151-157(2005).
  4. 마기중, 이군자, "콘택트렌즈", 초판, 대학서림, 서울, pp. 56-57(1995).
  5. Begley C. G., Caffery B., Nichols K. K., and Chalmers R., "Responses of contact lens wearers to a dry eye survey", Optom. Vis. Sci., 77(1):40-46(2000). https://doi.org/10.1097/00006324-200001000-00012
  6. 박형준, 이가영, "중학생의 컴퓨터 이용시간과 건성안과의 관계에 대한 고찰", 대한안과학회지, 43(3):449-456(2002).
  7. 이연진, 박상일, 이흠숙, 박미정, "소프트콘택트렌즈 착용에 의한 순목 횟수 변화", 한국안광학회지, 11(2):173-179(2006).
  8. 박미정, 권미정, 현선희, 김대수, "소프트콘택트렌즈의 단백질 부착 양상 및 가시광선투과도와 접촉각에 미치는 영향", 한국안광학회지, 9(1):53-68(2004).
  9. Guillon M. and Maissa C., "Dry eye symptomatology of soft contact lens wearers and nonwearers", Optom. Vis. Sci., 82(9):829-34(2005). https://doi.org/10.1097/01.opx.0000178060.45925.5d
  10. Sahai A. and Malik P., "Dry eye: prevalence and attributable risk factors in a hospital-based population", Indian J. Ophthalmol., 53(2):87-91(2005). https://doi.org/10.4103/0301-4738.16170
  11. Thai L. C., Tomlinson A., and Doane M. G., "Effect of contact lens materials on tear physiology", Optom. Vis. Sci., 81(3):194-204(2004). https://doi.org/10.1097/00006324-200403000-00012
  12. 이병준, 홍재형, 정다이, 박미정, "건성안 검사 방법의 신뢰도에 대한 연구", 한국안광학회지, 13(1):15-20(2008).
  13. Narayanan S., Miller W. L., Prager T. C., Jackson J. A., Leach N. E., McDermott A. M., Christensen M. T., and Bergmanson J. P., "The diagnosis and characteristics of moderate dry eye in non-contact lens wearers", Eye Contact Lens, 31(3):96-104(2005). https://doi.org/10.1097/01.ICL.0000140907.45705.E2
  14. Horwath-Winter J., Berghold A., Schmut O., Floegel I., Solhdju V, Bodner E., Schwantzer G., and Haller-Schober E. M., "Evaluation of the clinical course of dry eye syndrome", Arch. Ophthalmol., 121(10):1364-8(2003). https://doi.org/10.1001/archopht.121.10.1364
  15. Mengher L. S., Bron A.J., Tonge S. R., and Gilbert D. J., "A non-invasive instrument for clinical assessment of the pre-corneal tear film stability", Curr. Eye Res., 4(1):1-7(1985). https://doi.org/10.3109/02713688508999960
  16. Madden R. K., Paugh J. R., and Wang C., "Comparative study of two non-invasive tear film stability techniques", Curr. Eye Res., 13(4):263-269(1994). https://doi.org/10.3109/02713689408995787
  17. 임경직, 이진학, "건성안에서의 Tear Meniscus Height", 대한안과학회지, 33(1):29-31(1992).
  18. 최병철, 박성현, "SPSS와 SAS분석을 통한 실험계획법의 이해", 초판, 민영사, 서울, pp.26-30(2005).
  19. 박미라, 이재원, "EXCEL을 이용한 의학데이터의 통계분석", 초판, 자유아카데미, 서울, pp.159-165(2007).
  20. Glasson M. J., Hseuh S., and Willcox M. D., "Preliminary tear film measurements of tolerant and non-tolerant contact lens wearers", Clin. Exp. Optom., 82(5):177-181(1999). https://doi.org/10.1111/j.1444-0938.1999.tb06639.x
  21. Mengher L. S., Bron A. J., Tonge S. R., and Gilbert D. J., "Effect of fluorescein instillation on the pre-corneal tear film stability", Curr. Eye Res., 4(1):9-12(1985). https://doi.org/10.3109/02713688508999961
  22. Nichols J. J. and King-Smith P. E., ''The impact of hydrogel lens settling on the thickness of the tears and contact lens", Invest. Ophthalmol. Vis. Sci., 45(8):2549-2554(2004). https://doi.org/10.1167/iovs.04-0149
  23. Little S. A. and Bruce A. S., "Postlens tear film morphology, lens movement and symptoms in hydrogel lens wearers", Ophthalmic Physiol. Opt., 14(1):65-69(1994). https://doi.org/10.1111/j.1475-1313.1994.tb00559.x
  24. Geldis J. R. and Nichols J. J., "The impact of punctal occlusion on soft contact lens wearing comfort and the tear film", Eye Contact Lens, 34(5):261-265(2008). https://doi.org/10.1097/ICL.0b013e31817fa604
  25. Friedman N. J., "Impact of dry eye disease and treatment on quality of life", Current Opinion in Ophthalmology. 21(4):310-316(2010).
  26. Fahmy M., Long B., Giles T., and Wang C., "Comfort-Enhanced Daily Disposable Contact Lens Reduces Symptoms Among Weekly/Monthly Wear Patients", Eye & Contact Lens: Science & Clinical Practice. 36(4):215-219(2010). https://doi.org/10.1097/ICL.0b013e3181e5859f
  27. Jansen M. E., Begley C. G., Himebaugh N. H., and Port N. L., "Effect of contact lens wear and a near task on tear film break-up", Optom. Vis. Sci., 87(5):350-7(2010).
  28. Sullivan D. A., "Lacrimal gland, tear film, and dry eye syndromes", 1st Ed., Plenum Press, New York, USA, pp.403-410(1994).
  29. Gispets J., Sol R., and Varn C., ''The influence of water content of hydrogel contact lenses when fitting patients with tear film deficiency", Cont. Lens Anterior Eye, 23(1):16-21(2000). https://doi.org/10.1016/S1367-0484(00)80036-3
  30. Fonn D., Situ P., and Simpson T., "Hydrogel lens dehydration and subjective comfort and dryness ratings in symptomatic and asymptomatic contact lens wearers", Optom. Vis. Sci. 76(10):700-704(1999). https://doi.org/10.1097/00006324-199910000-00021
  31. Gispets J., Cardona, G., SoIR., Varn C., and Salazar F., "Central thickness of hydrogel contact lenses as a predictor of success when fitting patients with tear deficiency", Cont. Lens Anterior Eye, 25(2):89-94(2002). https://doi.org/10.1016/S1367-0484(02)00005-X
  32. Phillips A. J. and Stone J., "Contact lenses", 3rd Ed. Butterworths, London, UK, pp,382-440(1989).
  33. Thai L. C., Tomlinson A., and Ridder W. H., "Contact lens drying and visual performance: The vision cycle with contact lenses", Optom. Vis. Sci., 79(6):381-388(2002). https://doi.org/10.1097/00006324-200206000-00012
  34. Lira M., Santos L., Azeredo J., Yebra-Pimentel E., and Oliveira R., "The effect of lens wear on refractive index of conventional hydrogel and silicone-hydrogel contact lenses: A comparative study", Cont. Lens Anterior Eye, 31(2):89-94(2008). https://doi.org/10.1016/j.clae.2007.09.001