• 제목/요약/키워드: Magnetic probe

검색결과 264건 처리시간 0.029초

과학위성 1호의 우주 플라즈마 관측 시스템 (SPACE PHYSICS PACKAGE ON KAISTSAT-4)

  • 황정아;이재진;이대희;이진근;김희준;박재홍;민경욱;신영훈
    • 천문학논총
    • /
    • 제15권spc2호
    • /
    • pp.45-52
    • /
    • 2000
  • Four plasma instruments are currently under development for KAISTSAT-4 (K-4) which is scheduled for launch in 2002. They are the Solid-State Telescope, Electro-Static Analyzer, Langmuir Probe, and the Scientific Magnetometer, that will respectively allow in-situ detection of high energy and low energy components of auroral particles, ionospheric thermal electrons, and magnetic field disturbances. These instruments, together with the Far-ultraviolet IMaging Spectrograph, will provide micro-scale physics of Earth's polar ionosphere with detailed spectral information that has not been previously achieved with other space missions. In this paper, we review the concept of the four space plasma instruments as well as the anticipated results from the instruments.

  • PDF

무선주파수 간섭 측정을 위한 Printed Spiral Coil (PSC) 프로브의 고주파 모델링 (High-Frequency Modeling of Printed Spiral Coil Probes for Radio-Frequency Interference Measurement)

  • 김경민;송익환
    • 한국전자파학회논문지
    • /
    • 제29권1호
    • /
    • pp.10-19
    • /
    • 2018
  • 본 논문에서는 고주파 Radio-Frequency Interference (RFI) 측정용 프로브로 널리 쓰이는 Printed Spiral Coil(PSC)의 고주파 등가회로 모델이 제안되었다. 제안된 모델은 고주파 정합성을 확보하기 위하여 PSC의 설계변수에 기반한 분포 모델로 설계되었으며, 제안된 분포 등가회로 모델을 바탕으로 T-Pi 등가변환을 이용한 PSC의 고주파 해석적 모델 역시 새로이 제안되었다. 제안된 모델의 실제 고주파 RFI 측정 시 효용성을 확인하기 위하여, 임의의 RFI 노이즈 원으로 설계된 마이크로스트립 라인과 PSC 사이의 전달함수를 제안된 모델과 상호 인덕턴스를 결합하여 추출하였다. 제안된 PSC 모델의 자기 임피던스(self-impedance)와 전달함수는 3-dimensional field solver를 이용한 시뮬레이션 및 실 측정으로 검증되었으며, 6 GHz까지 높은 정합성을 보이는 것이 확인되었다. 제안된 PSC의 자기 임피던스 및 전달함수 모델은 GHz 영역의 고주파 통신대역에서의 RFI 측정용 프로브 설계 및 노이즈 간섭 예측에 활용될 수 있다.

Molecular Imaging in the Age of Genomic Medicine

  • Byun, Jong-Hoe
    • Genomics & Informatics
    • /
    • 제5권2호
    • /
    • pp.46-55
    • /
    • 2007
  • The convergence of molecular and genetic disciplines with non-invasive imaging technologies has provided an opportunity for earlier detection of disease processes which begin with molecular and cellular abnormalities. This emerging field, known as molecular imaging, is a relatively new discipline that has been rapidly developed over the past decade. It endeavors to construct a visual representation, characterization, and quantification of biological processes at the molecular and cellular level within living organisms. One of the goals of molecular imaging is to translate our expanding knowledge of molecular biology and genomic sciences into good patient care. The practice of molecular imaging is still largely experimental, and only limited clinical success has been achieved. However, it is anticipated that molecular imaging will move increasingly out of the research laboratory and into the clinic over the next decade. Non-invasive in vivo molecular imaging makes use of nuclear, magnetic resonance, and in vivo optical imaging systems. Recently, an interest in Positron Emission Tomography (PET) has been revived, and along with optical imaging systems PET is assuming new, important roles in molecular genetic imaging studies. Current PET molecular imaging strategies mostly rely on the detection of probe accumulation directly related to the physiology or the level of reporter gene expression. PET imaging of both endogenous and exogenous gene expression can be achieved in animals using reporter constructs and radio-labeled probes. As increasing numbers of genetic markers become available for imaging targets, it is anticipated that a better understanding of genomics will contribute to the advancement of the molecular genetic imaging field. In this report, the principles of non-invasive molecular genetic imaging, its applications and future directions are discussed.

Analysis of the local superconducting properties in YBCO coated conductors with striations

  • Kim, Muyong;Park, Sangkook;Park, Heeyeon;Ri, Hyeong-Cheol
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.25-30
    • /
    • 2015
  • In order to realize economical applications, it is important to reduce the ac loss of 2G high-temperature superconductor coated conductors. It seems to be reasonable that a multi-filamentary wire can decrease the magnetization loss. In this study, we prepared two samples of YBCO coated conductors with striations. We measured local superconducting properties of both samples by using Low Temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). The distribution of the local critical temperature of samples was analyzed from experimental results of Low Temperature Scanning Laser Microscopy (LTSLM) near the superconducting transition temperature. According to LTSLM results, spatial distributions of the local critical temperature of both samples are homogeneous. The local current density and the local magnetization in samples were explored from measuring stray fields by using Scanning Hall Probe Microscopy (SHPM). From SHPM results, the remanent field pattern of the one bridge sample in an external magnetic field confirms the Bean's critical state model and the three bridge sample has similar remanent field pattern of the one bridge sample. The local magnetization curve in the three bridge sample was measured from external fields from -500 Oe to 500 Oe. We visualized that the distribution of local hysteresis loss are related in the distribution of the remanent field of the three bridge sample. Although the field dependence of the critical current density must be taken into account, the relation of the local hysteresis loss and the remanent field from Bean's model was useful.

Doxorubicin Release from Core-Shell Type Nanoparticles of Poly(DL-lactide-co-glycolide)-Grafted Dextran

  • Jeong, Young-Il;Choi, Ki-Choon;Song, Chae-Eun
    • Archives of Pharmacal Research
    • /
    • 제29권8호
    • /
    • pp.712-719
    • /
    • 2006
  • In this study, we prepared core-shell type nanoparticles of a poly(DL-lactide-co-glycolide) (PLGA) grafted-dextran (DexLG) copolymer with varying graft ratio of PLGA. The synthesis of the DexLG copolymer was confirmed by $^1H$ nuclear magnetic resonance (NMR) spectroscopy. The DexLG copolymer was able to form nanoparticles in water by self-aggregating process, and their particle size was around $50\;nm{\sim}300\;nm$ according to the graft ratio of PLGA. Morphological observations using a transmission electron microscope (TEM) showed that the nanoparticles of the DexLG copolymer have uniformly spherical shapes. From fluorescence probe study using pyrene as a hydrophobic probe, critical association concentration (CAC) values determined from the fluorescence excitation spectra were increased as increase of DS of PLGA. $^1H-NMR$ spectroscopy using $D_2O$ and DMSO approved that DexLG nanoparticles have core-shell structure, i.e. hydrophobic block PLGA consisted inner-core as a drug-incorporating domain and dextran consisted as a hydrated outershell. Drug release rate from DexLG nano-particles became faster in the presence of dextranase in spite of the release rate not being significantly changed at high graft ratio of PLGA. Core-shell type nanoparticles of DexLG copolymer can be used as a colonic drug carrier. In conclusion, size, morphology, and molecular structure of DexLG nanoparticles are available to consider as an oral drug targeting nanoparticles.

JERS-1 L-band SAR Interferometry 를 이용한 연안매립지 지반침하 관측 (Ground Subsidence Estimation in a Coastal Reclaimed Land Using JERS-1 L-band SAR Interferometry)

  • 김상완;이창욱;원중선
    • 자원환경지질
    • /
    • 제35권5호
    • /
    • pp.465-478
    • /
    • 2002
  • JERS-1 L-밴드 SAR 위성에서 얻어진 5개의 interferogram을 이용하여 1996년 5월 2일부터 1998년 2월 21일 사이 연안매립지인 녹산 국가산업단지의 공단조성과정에서 발생한 지반침하량을 계산하였다. 약 16 m의 공간해상도를 갖는 레이더 관측결과는 현장측정 자료로부터 관측되기 어려운 세밀한 침하 양상을 잘 반영하였다. 정확도 검증을 위해 2-pass DInSAR로 구한 침하량을 Magnetic Probe Extensometer(측정정밀도:${\pm}$1 mm)를 사용하여 총 42개소에 서 측정된 현장자료와 비교하였다. 5개의 쌍으로부터 추정된 DInSAR침하량과 실측침하량의 평균 상관계수는 0.77 이다. 추정된 DInSAR 침하량 중 0.5 이상의 긴밀도를 갖는 점들만을 이용하여 계산한 경우 상관계수는 0.87이며, RMSE는 1.44 cm로 더욱 좋은 결과를 나타낸다. 또한 추정된 회귀선의 기울기는 1.04로 실측값과 DInSAR 추정값이 기울기 1에 가까운 선형관계를 잘 만족하고 있음을 보여준다. 즉 DInSAR 결과 긴밀도 0.5 이상의 지점을 이용하면 효과적으로 연안매립지의 침하량을 관측할 수 있다. DInSAR를 이용하여 계산된 녹산 국가산업단지에서 발생한 최대 누적침하량은 약 60 cm 정도이며, 연구지역의 북쪽과 남서쪽에서는 약 20 cm 이하의 침하가 관측되었다. 이러한 결과는 자연적인 지표변위 관측뿐만 아니라 지반공학적 응용분야에서도 DInSAR 기술이 매우 중요한 역할을 맡을 수 있음을 보여준다.

말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작 (Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment)

  • 김휘영;최진영;박성준;김희제
    • 벤처창업연구
    • /
    • 제2권1호
    • /
    • pp.153-169
    • /
    • 2007
  • 열작용에 의한 전자파의 안전성을 생각하는데 있어서는 , 이 30${\sim}$300MHz 부근의 주파수대가 가장 중요하고 기립 신장 방향의 공진 상태에서는 목, 슬 관절, 발목 등 가는 부분이 강하게 가열되는 위험이 있다. 이처럼 자기자극기는 시간적으로 변화하는 자계를 인체내부에 전계를 유도하여 무접촉성, 무침습적으로 깊고, 넓은 부위의 자극이 가능한 이점으로 말초신경, 뇌질환, 뇌신경, 근력, 요실금, 노인성, 근질환, 재활치료 등까지 근래에 와서 활발하게 연구가 활발히 진행 중이다. 마지막으로 초미니 자기신경 치료기를 말초신경계 질환치료에 적용하기 위하여 연구한 결과, 첫째로 자기루프 객체의 실린더 형태로 설계하고 동작전원과 제어장치를 구현하였고, 둘째로 루프 객체 실린더형이 프로브의 특성과 치료영역 범위와 치료펄스의 거리에 대한 유효영역을 구하였고, 셋째로 프로브의 형태에 따른 펄스포밍과 에너지 값을 구현하여, 병변에 따른 치료펄스를 구현할 수가 있었다. 특히, 특성실험을 통해 댐핑펄스 형태와 치료펄스 형태 등을 다양하게 구하게 되었다. 최근에 의학 발달로 무자극, 무침습에 따른 질환치료에 조금이라도 도움이 되고자 구현 하였다. 본 연구에서는 고진폭 치료펄스(전통적인 magneto-therapy)의 크게 대단한 강렬)는 짧은 시간에 치료효과를 극대화 하고, 미래에는 수요가 크게 확대 될 것으로 예측된다.

  • PDF

자기포화 와전류기법에 의한 자성 튜브 비파괴검사 (Nondestructive Examination of Ferromagnetic Tube Using Magnetic Saturation Eddy Current Technique)

  • 이희종;조찬희;송석윤;지동현;정지홍
    • 비파괴검사학회지
    • /
    • 제28권5호
    • /
    • pp.407-415
    • /
    • 2008
  • 원전 발전소 터빈계통을 구성하는 열교환기 튜브는 일반적으로 구리합금, 스테인리스강, 탄소강, 티타늄합금 등의 재질로 제작된다. 이들 재질중에서 페라이트계 type-439 스테인리스강은 자성 재질로서 오스테나이트계보다 더 높은 열전달율 가지며, 부식에 의해 유발되는 결함에 대해 더 높은 저항성을 가진다. 페라이트계 스테인리스강은 보통 발전소 열교환기의 저압급수가열기와 습분분리재열기에 사용된다. 저압급수가열기는 일반적으로 두께가 얇은 type-439 스테인리스강을 이용하는 반면에 습분분리재열기는 더 두꺼운 핀튜브를 사용한다. 이와 같이 터빈 습분분리재열기 튜브로 사용되는 type-439 스테인리스강 핀튜브는 터빈계통의 운전으로 인하여 손상이 발생할 수 있다. 손상에 의한 가장 대표적인 결함은 진동에 의해 발생할 수 있는 마모, 피로균열 등이며 마모성 결함은 일반적으로 튜브-튜브지지판에서 발생되는 것으로 보고되고 있다. 본 연구에서는 type-439 스테인리스강 자성체 튜브에 발생할 수 있는 결함을 검출하고 크기를 측정할 수 있는 자기포화 와전류탐상검사 기법의 능력을 평가하였다.

스핀밸브 바이오 센서를 이용한 혈액과 나노입자의 자성특성 검출 (The Detection of Magnetic Properties in Blood and Nanoparticles using Spin Valve Biosensor)

  • 박상현;소광섭;안명천;황도근;이상석
    • 한국자기학회지
    • /
    • 제16권3호
    • /
    • pp.157-162
    • /
    • 2006
  • 이온빔 증착 스퍼터링법과 고아 리소그래피법으로 FeMn-스핀밸브 바이오 센서를 제작하였다. 혈액내의 Fe를 포함한 헤모글로빈(Hemoglobin)과 나노 자성입자의 자성검출은 최대 자장감응 약 $0.1{\sim}0.8%/Oe$인 거대자기저항 스핀밸브 바이오 센싱소자를 이용하였다. 사용된 혈액은 인체의 피였고, Co-페라이트 나노 자성입자는 수용성 무정형 실리카로 코팅이 되었으며, 그 크기의 평균직경의 범위는 9nm에서 50nm이었다. 실제 크기가 $5x10{\mu}m^2 $ 혹은 $2x6{\mu}m^2 $로 제작된 센싱소자의 4 전극 중 전류 입력단자에 흐르는 감지전류는 1 mA로 하였다. 혈액과 나노자성 입자가 소자의 중앙부분으로 떨어졌을 때, 출력신호는 각각 자성 여부의 검출 특성을 알 수 있는 충분한 크기로 나타났다.

SNU 1.5MV 반데그라프 가속기 (IV) -자기 4극 렌즈의 제작과 수차의 분석- (SNU 1.5MV Van de Graaff Accelerator (IV) -Fabrication and Aberration Analysis of Magnetic Quadrupole Lens-)

  • 박혜일;최병호;최희동
    • Nuclear Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 1986
  • SNU 1.5MV 반데그라프 가속기의 표적상자 전단에서 사용될 자기 4극 렌즈를 제작하고 그 광학적 특성을 측정 및 분석하였다. 렌즈의 칫수는 자극 길이 180mm, 구경 반경 25mm, 자극편 반경 28.75mm이며 자극과 철심의 재료로는 탄소강 KS-SM40C를 사용하였다. 코일은 자극 당 480회 감아 공냉식을 채택하고 있다. 제작한 렌즈에 직류 전류 2.99$\pm$0.03A를 흘리며 Hall 탐침소자를 써서 r,$\theta$,z의 각 방향에 대해 여러 지점에서 자장 요소 $B_{\theta}$, $B_{\gamma}$을 측정하였다. 측정된 자료에 대한 면적 적분과 직교성 다항함수 fitting을 통하여 렌즈 중심에서 자장 구배 G=566.3$\pm$2.1 gauss/cm, 렌즈축 상에서 유효길이 L=208.3$\pm$1.44mm로 나타났다. 렌즈의 다극 요소는 최소자승법을 써서 20극까지 결정하였다. 결과로서 렌즈 중심의 18mm 반경 이내의 영역에서 6극 요소 대 4극 요소의 비는 1.4$\pm$0,9% 이하이고, 기타 다극 요소들은 모두 0.5% 미만임을 얻었다.

  • PDF