• Title/Summary/Keyword: M/T-method

Search Result 2,839, Processing Time 0.035 seconds

Synthesis and Characterization of Nb, Mo-doped and Nb/Mo-codoped Monoclinic VO2 Nanoparticles and Their Thin Films by Hydrothermal/Post-Thermal Transformation and Wet-Coating Method

  • Kim, Jongmin;Jung, Young Hee;Kwak, Jun Young;Kim, Yeong Il
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.2
    • /
    • pp.94-101
    • /
    • 2019
  • Nb, Mo-doped and Nb/Mo-codoped $VO_2(M)$ nanocrystallites with various doping levels were synthesized for the first time by a hydrothermal and post thermal transformation method. The reversible phase transition characteristics of those doped $VO_2(M)$ was comparatively investigated. Nb-doping of $VO_2(M)$ by this method resulted in a very efficient lowering of the transition temperature ($T_c$) with a rate of $-16.7^{\circ}C/at.%$ that is comparable to W-doping, while Mo-doping did not give a serious reduction of $T_c$ with only a rate of $-5.1^{\circ}C/at.%$. Nb/Mo-codoping gave a similar result to Nb-doping without a noticeable difference. The thin films of Nb-doped and Nb/Mo-codoped $VO_2(M)$ with a thickness of ca. 120 nm were prepared by a wet-coating of the nanoparticle-dispersed solutions. Those films showed a good thermochromic modulation of near infrared radiation with 30-35% for Nb-doped $VO_2(M)$ and 37-40% for Nb/Mo-codoped ones. Nb/Mo-codoped $VO_2(M)$ film showed slightly enhanced thermochromic performance compared with Nb-doped $VO_2(M)$ film.

Fabrication of multi-layer $high-T_c$ superconducting tapes by a rolling process (로울링법을 이용한 고온 초전도 다심선재 제조)

  • 김민기;허원일;최명호;한병성
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.600-604
    • /
    • 1996
  • High-T$_{c}$, superconducting wire is very important element for the application of electrical power systems. But it is very difficult to develope the long high T, wire with excellent properties. BiSrCaCuO multi-layer tapes are fabricated by a rolling method and pressing method sintered for several step at 840.deg. C. The critical current densities of 637 filament multi-layer tapes sintering 100 hours fabricated by the rolling method and pressing method are 1.3*10$^{4}$ A/cm$^{2}$ and 5.5*10$^{3}$ A/cm$^{2}$. The critical cur-rent densites of multi-layer tapes made by rolling method are found to be better than those fabricated by the powder-in-tube method and pressing process. As result, the rolling method is the best way to fabricated the multi-layer filament.t.

  • PDF

Online-Effects of Transcranial Direct Current Stimulation on Bimanual Force Control Performances in Healthy Young Adults (실시간 비침습적 뇌전기 자극이 양손 힘 조절능력에 미치는 영향)

  • Tae Lee, Lee;Joon Ho, Lee;Nyeonju, Kang
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.121-127
    • /
    • 2022
  • Objective: The purpose of this study was to investigate potential effects of transcranial direct current stimulation (tDCS) on bimanual force control capabilities in healthy young adults. Method: Eighteen right-handed healthy young adults (10 females and 8 males; age: 23.55 ± 3.56 yrs) participated in this crossover design study. All participants were randomly allocated to both active-tDCS and sham-tDCS conditions, respectively. While receiving 20 min of active- or sham-tDCS interventions, all participants performed bimanual isometric force control tasks at four submaximal targeted force levels (i.e., 5%, 10%, 15, and 20% of maximal voluntary contraction: MVC). To compare bimanual force control capabilities including force accuracy, variability, and regularity between active-tDCS and sham-tDCS conditions, we conducted two-way repeated measures ANOVAs (2 × 4; tDCS condition × Force levels). Results: We found no significant difference in baseline MVC between active-tDCS and sham-tDCS conditions. Moreover, our findings revealed that providing bilateral tDCS including anodal tDCS on left primary motor cortex (M1) and cathodal on right M1 while conducting bimanual force control trials significantly decreased force variability and regularity at 5%MVC. Conclusion: These findings suggest that providing bilateral tDCS on M1 areas may improve bimanual force control capabilities at a relatively low targeted force level.

Fabrication and Characterization of 70 nm T-gate AlGaAs/InGaAs/GaAs metamorphic HEMT Device (70 nm T-게이트를 갖는 InGaAs/InAlAs/GaAs metamorphic HEMT 소자의 제작 및 특성)

  • 김성찬;임병옥;백태종;고백석;신동훈;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.19-24
    • /
    • 2004
  • In this paper, we have demonstrated the fabrication of a 70 nm foot print of the T-gate by using a positive resist ZEP520/P(MMA-MAA)/PMMA trilayer by double exposure method without a thin dielectric supporting layer on the substrate. The device performance was characterized by DC and RF measurement. The fabricated 70 nm InGaAs/InAlAs MHEMTS with 70 ${\mu}{\textrm}{m}$ unit gate width and 2 fingers showed good DC and RF characteristics of Idss, max =228.6 mA/mm, gm =645 mS/mm, and fT =255 GHz, respectively.

Cetyl Trimethyl Ammonium Bromide-coated Nickel Ferrite Nanoparticles for Magnetic Hyperthermia and T2 Contrast Agents in Magnetic Resonance Imaging

  • Lee, Da-Aemm;Bae, Hongsubm;Rhee, Ilsum
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1334-1339
    • /
    • 2018
  • Spherical nickel ferrite nanoparticles were synthesized using the thermal decomposition method and coated with cetyl trimethyl ammonium bromide (CTAB) after the synthesis. Transmission electron microscopy images showed that the average diameter of the particles was 9.40 nm. The status of the CTAB-coating on the surface of the particles was checked using Fourier-transform infrared spectroscopy. Their hysteresis curve showed that the particles exhibited a superparamagnetic behavior. The $T_1$ and the $T_2$ relaxations of the nuclear spins were observed in aqueous solutions of the particles with different particles concentrations by using a magnetic resonance imaging (MRI) scanner, which showed that the $T_1$ and the $T_2$ relaxivities of the particles in water were $0.57mM^{-1}{\cdot}s^{-1}$ and $10.42mM^{-1}{\cdot}s^{-1}$, respectively. In addition, using an induction heating system, we evaluated their potentials for magnetic hyperthermia applications. The aqueous solution of the particles with a moderate concentration (smaller than 6.5 mg/mL) showed a saturation temperature larger than the hyperthermia target temperature of $42^{\circ}C$. These findings show that the CTAB-coated nickel ferrite particles are suitable for applications as $T_2$ contrast agents in MRI and heat generators in magnetic hyperthermia.

A Base AOP Bit-Parallel Non-Systolic for $AB^2+C$ Computing Unit for $GF(2^m)$ ($GF(2^m)$상의 AOP 기반 비-시스토릭 병렬 $AB^2+C$연산기)

  • Hwang Woon-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1538-1544
    • /
    • 2006
  • This paper proposes a non-systolic parallel $AB^2+C$ Computing unit based on irreducible AOP order m of $GF(2^m)$. Proposed circuit have only AND gates and EX-OR gates, composes of cyclic shift operation, multiplication operation power operation power-sum operation and addition operation using a merry irreducible AOP. Suggested operating a method have an advantage high speed data processing, low power and integration because of only needs AND gates and EX-OR gates. $AB^2+C$ computing unit has delay-time of $T_A+(1+[log^m_2])T_X$.

A Comparative Analysis of GBEF According to Image Aquisition Method in Hepatobiliary Scan (간담도스캔의 영상수집방법에 따른 담즙배출율의 비교분석)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.8-16
    • /
    • 2014
  • Purpose The quantitative analysis of gallbladder emptying is very important in diagnosis of motility disorder of gallbladder and in biliary physiology. The GBEF obtain the statics aquisition method or the dynamic acquisition method in two ways. The purpose of this study is to compare the GBEF value of statics acquisition method and the dynamic acquisition method. And we find the best way for calculate GBEF. Materials and Methods The quantitative hepatobiliary scan with $^{99m}Tc$-mebrofenin was performed of 27 patients. Initial images were acquired statically, for 60 min after injection of the radioactive tracer. And if the gallbladder is visualized to 60 min, performed stimulation of gallbladder (1egg, 200 mL milk). After that, started acquisition of dynamic image for 30 min. After that, image of after fatty meal of the statics method were acquired on equal terms with 60 min image. The statics GBEF was calculated using the images of before fatty meal and post fatty meal by the statics method. The dynamic GBEF was calculated using the images of time of maximum bile juice uptake ($T_{max}$) and time of minimum bile juice uptake ($T_{min}$) images from the gallbladder time-activity curve. A bile juice is secreted from gallbladder while eating a fatty meal. that is named early GBEF and that was calculated using before fatty meal image of the statics method and 1 min image of the dynamic method. Results The result saw very big difference between two according to $T_{max}$. The result, were as follows. 1) In case of less than 1 min, the dynamic mean GBEF was $40.1{\pm}21.7%$, the statics mean GBEF was $51.5{\pm}23.6%$ in 16 cases. The early mean GBEF was $14.0{\pm}29.1%$. The GBEF of statics method was higher because that include secreted bile juice while performed stimulation of gallbladder. A difference of GB counts according to acquisition method and the early bile juice counts was $17.6{\pm}14.8%$ and $13.5{\pm}15.3%$. 2) In case of exceed than 1 min, the dynamic mean GBEF was $31.0{\pm}19.7%$, the statics mean GBEF was $21.3{\pm}19.4%$ in 7 cases. The early GBEF was $-6.9{\pm}4.9%$. The GBEF of dynamic method was higher because that include concentrated bile juice to $T_{max}$. A difference of GB counts according to acquisition method and the early bile juice counts was $14.3{\pm}7.3%$ and $5.9{\pm}3.9%$. Conclusion The statics method is very easy and simple, but in case of $T_{max}$ delay, the GBEF can be lower. The dynamic method is able to calculate accurately in case of $T_{max}$ delay, but in case of $T_{max}$ is less than 1 min, the GBEF can be lower because dynamic GBEF exclude secreted bile juice while performed stimulation of gallbladder. The best way to calculate GBEF is to scan with dynamic method preferentially and to choose suitable method between the two way after conform $T_{max}$ on the T-A curve of the dynamic method.

  • PDF

Binomial Sampling Plan for Estimating Tetranuchus urticae(Acari: Tetranychidae)Populations in Glasshouse Rose Grown by Arching Method (아치형 재배 시설장미에서 점박이응애의 이항표본조사법 개발)

  • 조기종;박정준;박흥선;김용헌
    • Korean journal of applied entomology
    • /
    • v.37 no.2
    • /
    • pp.151-157
    • /
    • 1998
  • Infestations of two spotted spider mite (TSSM), Tetranychus urticae Koch, on glasshouse rose (Rosa sp.) grown by an arching method, were determined by counts of the number of TSSM per leaflet in Buyeo, Chungnam Province, for a 2-yr period. Binomial sampling plans were developed based on the relationship between mean density per leaflet (m), and proportion of leaflets infested with ( T mites (PT), according to the empirical model In (m) = a+p In (-ln (1 -PT)). T was defined as tally threshold, and set to 1, 3, 5, 7, and 9 mites per leaflet. Increasing sample size had little effects on the precision of the binomial sampling plan, regardless of tally threshold. However, the precision increased with higher tally thresholds. There was a negligible improvement in precision with T ) 7 mites per leaflet. T= 7 was chosen as the best tally threshold for estimating densities of TSSM based on the precision of the model. Independent data set was used to evaluate the model. The binomial model with T= 7 provided reliable predictions of mean densities of TSSM observed on the commercial glasshouse roses.

  • PDF

Detection of N,N-Dimethylaniline in Ampicillin Trihydrate by Thin Layer Chromatography and Densitometry (박층크로마토그라피 및 농도 측정법에 의한 Ampicillin Trihydrate 중의 N,N-Dimethylaniline의 검색)

  • 이왕규;김박광;심창구
    • YAKHAK HOEJI
    • /
    • v.22 no.4
    • /
    • pp.238-241
    • /
    • 1978
  • A simple and convenient method of detecting N, N-dimethy laniline (D.M.A.) residues in ampicillin trihydrate (A.T.) was established. D.M.A. was extracted by chloroform from the chloroform presaturated N/10-ammonia water solution of A.T. and chromatographed on silica gel G thin layer. Blue spot appeared in 15minutes after spray of 2, 6-dichloroquinonechlorimide solution was compared with the blue spot of reference concomitantly processed. The developing solvent was prepared by mixing equal volume of cyclohexane and chloroform. To quantitate the amount of D.M.A. in A.T., T.L.C. was performed with the Eastmann Chromatogram sheet, then color density was measured by Cosmo Superclick densitometer. The developing solvent at this time was cyclohexane-chlorofonn (3+7) mixture. The peak areas obtained with the amount of D.M.A ranging from 0.05 to 2.0 .mu.g were linear to color density. Better sensitive results would be available with the densitometer equipped with monochromator.

  • PDF

Logistics Delivery Route Optimization Method Based on IoT Focus on IoT device and IoT platform (IoT를 기반으로 한 택배 배송 경로 최적화 방안 IoT 장치와 IoT 플랫폼을 중심으로)

  • Song, Ha-Yoon;Mo, Jun-Sang
    • Annual Conference of KIPS
    • /
    • 2018.05a
    • /
    • pp.566-568
    • /
    • 2018
  • 최근 IoT 기술이 산업 전반에 걸쳐 적용되고 있다. 본 논문에서는 기존 택배 시스템에서 비효율적인 경로로 배송되는 문제점을 개선하기 위해 택배 시스템에 IoT 기술을 적용하여 경로 최적화를 도모하며 IoT 장치와 IoT 플랫폼을 중심으로 문제 해결 솔루션을 제시한다.