• Title/Summary/Keyword: Loop filter voltage

Search Result 168, Processing Time 0.025 seconds

An Implementation of Active Power Filler that Adopts to a Frequency Variation using the VCGIC(Voltage Controlled Generalized Impedance Converter (전압 제어 임피던스 변환기를 이용한 전원주파수 적응형 능동 전력 필터의 구현)

  • Jang, Mok-Sun;Kim, Sang-Hoon;Lee, Hu-Chan;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.88-95
    • /
    • 2006
  • This paper proposes an analog type Active Power Filter that adapts to the frequency change of a distributed power supply system. The proposed system removes the harmonic currents in the source power by injecting a compensation current that has the same frequency, 180 degree out of phase with the harmonic currents generated by the load. The detection of the harmonics in the source power for creating the compensating current is realized by a PLL(Phase Lock Loop) and a VCGIC(Voltage Controlled Generalized Impedance Converter). The operation of the proposed system is verified by simulation and experiment.

A novel control strategy of active power filter type bidirectional UPS (능동필터형 쌍방향 UPS의 새로운 제어기법)

  • Kim, Je-Hong;Yeom, Sang-Ku;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2082-2084
    • /
    • 1997
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system Performance is verified by the simulation and experimental results.

  • PDF

A Two State Feedback Active Damping Strategy for the LCL Filter Resonance in Grid-Connected Converters

  • Gaafar, Mahmoud A.;Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1587-1597
    • /
    • 2016
  • A novel active damping strategy for the LCL filter resonance is proposed using the grid current and the capacitor voltage. The proposed technique is deduced in the continuous time domain and a discussion for its discrete implementation is presented. According to the proposed technique, instability of the open loop system, which results in non-minimum phase behavior, can be avoided over wide range of resonant frequencies. Moreover, straightforward co-design steps for both the fundamental current regulator and the active damping loops can be used. A numerical example along with experimental results are introduced to validate the proposed strategy performance over wide range of resonant frequencies.

A Proposal on Fast Pull-in PLL with Clock Count Type Frequency Detector

  • Fujimoto, Kuniaki;Sasaki, Hirofumi;Yahara, Mitsutoshi;Murshed, Mohammad.M.
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.187-190
    • /
    • 2000
  • In this paper, we proposed a PLL with the clock count type frequency detector, in which the very fast pull-in time can be realized by resetting the VCO at the rising of input signal after charging the capacitor of loop filter with the voltage corresponding to the frequency of the input signal.

  • PDF

Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion (직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현)

  • Lee, Sang-Hoey;Cha, Han-Ju;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.

Control Strategy of Resonant DC Link Inverter for UPS (UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구)

  • Beak, J.W.;Yoo, D.W.;Min, B.G.;Ryu, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

A Low-Power CMOS Continuous-Time Sigma-Delta Modulator for UMTS Receivers (UMTS용 수신기를 위한 저 전력 CMOS 연속-시간 시그마-델타 모듈레이터)

  • Lim, Jin-Up;Choi, Joong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.65-73
    • /
    • 2007
  • This paper presents a low power CMOS continuous-time $\Sigma\Delta$ (sigma-delta) modulator for UMTS receivers. The loop filter of the continuous-time $\Sigma\Delta$ modulator consists of an active-RC filter which performs high linearity characteristics and has a simple tuning circuit for low power operating system The architecture of this modulator is the $3^{rd}-order$ 4-bit single loop configuration with a 24 of OSR (Oversampling Ratio) to increase the power efficiency. The modulator includes a half delay feedback path to compensate the excess loop delay. The experimental results of the modulator are 71dB, 65dB and 74dB of the peak SNR, peak SMR and dynamic range, respectively. The continuous-time $\Sigma\Delta$ modulator is fabricated in a 0.18-um 1P4M CMOS standard process and dissipates 15mW for a single supply voltage of 1.8V.

Analysis of PLL Phase Noise Effect for High Data-rate Underwater Communications

  • Lee, Chong-Hyun;Bae, Jin-Ho;Hwang, Chang-Ku;Lee, Seung-Wook;Shin, Jung-Chae
    • International Journal of Ocean System Engineering
    • /
    • v.1 no.4
    • /
    • pp.205-210
    • /
    • 2011
  • High data-rate underwater communications is demanded. This demand imposes stringent requirements on underwater communication equipment of phase-locked-loop (PLL). Phase noise in PLL is unwanted and unavoidable. In this paper, we investigate the PLL phase noise effect on high order QAM for underwater communication systems. The phase noise model using power spectral density is adopted for performance evaluation. The phase noise components considered in PLL are reference oscillator, voltage controlled oscillator (VCO), filter and divider. The filters in PLL noise are assumed to be second order active and passive low pass filters. Through simulation, we analyze the phase noise characteristics of the four components and then investigate the performance improvement factor of each component. Consequently, we derive specifications of VCO, phase detector, divider to meet performance requirement of high data-rate communication using QAM under phase noise influence.

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

There-Phase Voltage-Source Soft-Switching Inverter with Auxiliary High Frequency Transformer Linked Power Regeneration Resonant Snubbers

  • Hattori, Hiroshi;Nakaoka, Mutsuo;Sakamoto, Kenji
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.153-158
    • /
    • 1998
  • In this paper, a prototype of the auxiliary resonant commutated snubber circuit(ARCS) with a high frequency transformer power regeneration loop is described for voltage source type sinewave inverter system. This is a new soft switching topology developed for three phase voltage source soft-switching inverter, active power filter and reactive power compensator has significant advantage of current rating reduction for auxiliary active switching devices. In addition, this paper presents a novel prototype of voltage-source soft switching space vector-modulated inverter with ARCS mentioned above, which is more suitable and acceptable for high-power utility interactive power conditioning, along with a digital control scheme. The steady-state operating analysis of ARCS has the remarkable features and the practical design procedure of this resonant snubber are illustrated on the basis of computer simulation analysis. The operating performance evaluations in the steady-state of this three phase voltage source soft switching inverter are discussed and compared with the three phase voltage source hard switching inverter.