• Title/Summary/Keyword: Load switch

Search Result 457, Processing Time 0.028 seconds

The Study of the Verification Test for Development of Contacts(50kA) of Making Switch and Back Up Breaker (대용량(50kA)의 Making Switch와 Back Up Breaker 접점 개발에 따른 검증시험의 연구)

  • Kim Sun-Koo;Kim Won-Man;La Dae-Ryeol;Roh Chang-Il;Lee Dong-Jun;Jung Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.842-844
    • /
    • 2004
  • The Back Up Breaker and Making Switch are very important equipments for the short circuit test facility, and contacts are the most important parts of the above switches. There are very many kind of contacts according to switches characteristic and should be done the verification test before use, especially development contacts. This study describes the class of switches, arc chute, material of whole contacts and essential test for verification. The essential test for verification are dielectric test, mechanical operation test, short-time withstand current test, load current breaking test, and short-circuit making current test etc.

  • PDF

Effective Compensation Method of Power Factor at Induction Load Using MERS(MAGNETIC ENERGY RECOVERY SWITCH) (단상유도성 부하와 직렬 연결된 MERS 효과검증)

  • Lee, Dong-Geun;Choi, Dong-Uk;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1691-1692
    • /
    • 2006
  • 본 논문은 역률개선 효과가 있는 MERS(Magnetic Enery recovery switch)를 사용하여 에너지 효율에서의 결과를 입증하고자 한다. 전원과 유도성부하에 직렬 연결된 MERS는 Full Bridge와 비슷한 구성으로 전력용 MOSFET(or IGBT) SWITCH 4개와 전해 DC콘덴서 1개로 구성되어진다. MERS의 콘덴서는 부하와 콘덴서의 리액턴스, $Xc<X_L$을 만족하는 콘덴서의 용량을 선택하고 콘덴서에 충전된 전압에 의해 부하의 유도계수를 보상하여 역률을 1로 추종하며 개선된다. 이때 스위치는 전원 전압에 대해 zero-voltage switching과 zero-current switching을 하게 된다. 만약 부하가 변하더라도 $Xc<X_L$을 만족한다면 자동적으로 역률은 1에 맞추어지게 된다.

  • PDF

The Analysis of operational characteristic of superconducting current generator by computer simulation (시뮬레이션을 통한 정류형 초전도 전류발생장치의 동작특성해석)

  • Chu, Yong;Joo, Min-Seok;Hong, Jung-Bae;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.95-97
    • /
    • 1995
  • A superconducting current generator, or a superconducting rectifier(SCR) is used as a current source to energize a superconducting magnets in SMES, MRI. We selected a full-wave SCR among various SCR models and analyzed its operational characteristics by computer simulation. In process of pumping the current, the improvement of performance is dependent on how much bigger the open resistance of the switch is in comparison to load coil impedance when one of two switches become active. Faster transfer can he seen in resistive commutation mode by shortening the time elapsed for the resistance to arrive at certain level from zero state. Although recovery time for the switch has no direct effect on current pumping, optimal switch design is needed to increasing operational frequency.

  • PDF

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

Study on High Voltage Switch Using IGBT (IGBT를 사용한 고전압 스위치에 관한 연구)

  • Park, S.S.;Kim, S.C.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.556-558
    • /
    • 1996
  • PLS 2-GeV linac has 11 sets of high power klystron-modulator system as a main RF source for the beam acceleration. The modulators can provide 200-MW peak pulsed power(400-kV, 500-A) with a pulse width of $7.5{\mu}s$(ESW), a maximum pulse repetition rate of 120-Hz at the full power level. The DC power supply provides a 25-kV, 7-Adc and the charging system consists of a charging inductor, charging capacitor, and the diode for reverse current protection. The charged PFN voltage by a LC resonant charging method has two times of the DC high voltage and the pulsed power is delivered to the load by a thyratron switch. To reduced the press of high voltage lit thyratron switch, the command charging is the best method. In this article, the high voltage switch for the command charging method is tested to the start work and the system is presented with the experiment results of the trigger and operational characteristics.

  • PDF

Novel Single Switch DC-DC Converter for High Step-Up Conversion Ratio

  • Hu, Xuefeng;Gao, Benbao;Huang, Yuanyuan;Chen, Hao
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.662-671
    • /
    • 2018
  • This paper presents a new structure for a step up dc-dc converter, which has several advantageous features. Firstly, the input dc source and the clamped capacitor are connected in series to transfer energy to the load through dual voltage multiplier cells. Therefore, the proposed converter can produce a very high voltage and a high conversion efficiency. Secondly, a double voltage clamped circuit is introduced to the primary side of the coupled inductor. The energy of the leakage inductance of the coupled inductor is recycled and the inrush current problem of the clamped circuits can be shared equally by two synchronous clamped capacitors. Therefore, the voltage spike of the switch tube is solved and the current stress of the diode is reduced. Thirdly, dual voltage multiplier cells can absorb the leakage inductance energy of the secondary side of the coupled inductor to obtain a higher efficiency. Fourthly, the active switch turns on at almost zero current and the reverse-recovery problem of the diodes is alleviated due to the leakage inductance, which further improves the conversion efficiency. The operating principles and a steady-state analysis of the continuous, discontinuous and boundary conduction modes are discussed in detail. Finally, the validity of this topology is confirmed by experimental results.

A Laterally Driven Electromagnetic Microoptical Switch Using Lorentz force (로렌츠 힘을 이용한 평면구동형 마이크로 광스위치)

  • Han, Jeong-Sam;Ko, Jong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.195-201
    • /
    • 2005
  • A laterally driven electromagnetic microactuator (LaDEM) is presented, and a micro-optical switch is designed and fabricated as a possible application. LaDEM provides parallel actuation of the microactuator to the silicon substrate surface (in-plane mode) by the Lorentz force. Poly-silicon-on-insulator (Poly-SOI) wafers and a reactive ion etching (RIE) process were used to fabricate high-aspect-ratio vertical microstructures, which allowed the equipment of a vertical micro mirror. A fabricated arch-shaped leaf spring has a thickness of $1.8{\mu}m$, width of $16{\mu}m$, and length of $800{\mu}m$. The resistance of the fabricated structure fer the optical switch was approximately 5$\Omega$. The deflection of the leaf springs increases linearly up to about 400 mA and then it demonstrates a buckling behavior around the current value. Owing to this nonlinear phenomenon, a large displacement of $60{\mu}m$ could be measured at 566 mA. The displacement-load relation and some dynamic characteristics are analyzed using the finite element simulations.

Novel High Step-Up DC/DC Converter Structure Using a Coupled Inductor with Minimal Voltage Stress on the Main Switch

  • Moradzadeh, Majid;Hamkari, Sajjad;Zamiri, Elyas;Barzegarkhoo, Reza
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2005-2015
    • /
    • 2016
  • A high-step-up DC/DC converter for renewable energy systems is proposed. The proposed structure provides high voltage gain by using a coupled inductor without the need for high duty cycles and high turn ratios. The voltage gain is increased through capacitor-charging techniques. In the proposed converter, the energy of the leakage inductors of the coupled inductor is reused. This feature reduces the stress on the switch. Therefore, a switch with low ON-state resistance can be used in the proposed converter to reduce losses and increase efficiency. The main switch is placed in series with the source. Therefore, the converter can control the energy flow from the source to the load. The operating principle is discussed in detail, and a steady state analysis of the proposed converter is conducted. The performance of the proposed converter is verified by experimental results.

Design of Capacitor Load Bank for Capacitive Current Switching Tests (진상소전류시험용 Capacitor Load Bank 설계)

  • Roh, Chang-Il;La, Dae-Ryeol;Kim, Sun-Koo;Jung, Heung-Soo;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.106-108
    • /
    • 2002
  • Capacitive current switching test for circuit breaker and load breaker switch requires special attention because, after current interruption, the capacitive load contains an electrical charge and can cause dielectric restrike and re-ignition of the switching devices. therefore dielectric strength of capacitor load bank shall be able to withstand 4Vt (Vt : test voltage) and charging voltage discharged within 1 min. In this paper presents both characteristic of capacitive current switching tests and design of capacitor load bank.

  • PDF

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • 송인호;최창호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute(KAERI) in Taejon to supply power with Korea Superconducting Tokamak Advanced Research(KSTAR) Neutral Beam Injection(NBI) system. NBI system requires fast cutoff of the flower supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply. There are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply. Various results taken during the commissioning phase with a 100kW resistive load and NBI source arc shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver during thefabrication and test and solutions are also presented.