• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.026 seconds

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation (카올린 오손물 누적량 및 누설전류 변화에 관한 연구)

  • Park, Jae-Jun;Song, Il-Keun;Lee, Jae-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

The experimental study of $\gamma$ ray irradiation effect on electrical properties of B-kind insulator ($\gamma$선조사에 의한 B종절연재료의 전기적 특성변화에 대한 실험적 연구)

  • 천희영;성영권;이덕출
    • 전기의세계
    • /
    • v.18 no.2
    • /
    • pp.15-20
    • /
    • 1969
  • The main focus of this paper is on the study of the .gamma. ray irradiation effect upon the electrical properties of a B-kind insulator which is one of the inorganic insulators. The mica is so typical of the B kind insulators as to be selected for a sample. DC, AC, and Impulse voltage is applied to the variable .gamma. ray irradiated dose samples with the constant time duration and the time variable samples with the .gamma. ray irradiated dose. The dielectric breakdown voltage and dielectric constant are measured from the samples and we get the experimental data that the dielectric breakown voltage variations are relatively large, but the dielectric constants are almost constant. The above conclusion is useful for the selection and application of the inorganic insulators under the irradiation effects, and we expect that the conclusion can apply to not only B-kind insulators but also the inorganic insulators.

  • PDF

Reliability Assessment of Polymer Insulators by Accelerated Aging Test (가속열화시험에 의한 폴리머애자의 신뢰성 평가)

  • Han, Jae-Hong;Lee, Byung-Sung;Jung, Jong-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.10-14
    • /
    • 2001
  • In order to assess the long-tenn reliability of polymer insulators for distribution power systems, we have developed the accelerated aging test method which can simulate the operation conditions. In this study, 3000 hours aging test for 4 kinds of polymer insulators has been completed by the developed accelerated aging test. After 3000 hours aging test, visual inspection and electrical tests were carried for identifying a change of characteristics. Some specimens showed the surface erosion and the manufacturing defect. In the electrical tests, the wet flashover voltage was significant1y decreased by the accelerated aging test. In comparison with the field-aged polymer insulators, it can be concluded that the developed test method can evaluate the long-tenn reliability within short time and screen the manufacturing defect.

  • PDF

Characterization of Field-Aged Polymer Insulators for Distribution Power Systems (배전용 폴리머애자의 현장열화 특성평가)

  • 이병성;김찬영;한재홍
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.847-858
    • /
    • 2000
  • The aging characteristics of 2 kinds of 3 years field-aged distribution polymer insulators which were dismounted from 5 regions have been investigated by electrical test and material characterization. Although the tan $\delta$of specimens prepared from weathershed was increased with surface aging, the tan $\delta$and leakage current of real products had no difference between virgin and dismounted ones. Due to the aging, all dismounted polymer insulators had micro-cracks on the surface of weathershed and only the products of manufacturer B showed the reduction of OIT(oxidation induction time). But, there were no differences between virgin and dismounted products in contact angle and chemical structure. Therefore, it can be considered that the aging is only limited on the surface of dismounted polymer insulators and that NMR technique are very useful to evaluate the aging of polymer materials.

  • PDF

A Combined Aging Test Facility for Evaluating an Aging Characteristics of Distribution Polymer Insulators (배전용 폴리머애자 열화특성 평가를 위한 복합열화 시험장치 구축)

  • Lee, Byung-Sung;Han, Jae-Hong;Kim, Chan-Young;Yoon, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1948-1950
    • /
    • 2000
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. Especially, these insulators are subjected to the environmental stress such as ultraviolet radiation, electrical stress, mechanical load, etc.. Hence, in this paper, we simulated the factors having influence on aging of polymer insulators using the combined aging test chamber. In order to evaluate an aging characteristics with time, we measured leakage current on these insulators to make out the degree of aging.

  • PDF

An Application Study of the Closed Type Section Insulators to the High Speed Catenary System (Closed Type 절연구분장치 적용에 관한 연구)

  • 최규형;이기원
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.498-502
    • /
    • 2002
  • Section insulators are indispensible devices for the electric railways, which divide electrical connections between the trolley lines without losing mechanical connections, and this means that they should have both good electrical insulation performance and mechanical performance for pantograph interaction. This paper reviews some technical aspects of the several type section insulators and makes analysis of difficulties during operation. The closed type section insulators are proposed for newly electrified railways, because they have good mechanical and electrical performances for high speed trains up to 200[km/H]. Technical specifications of closed-type section insulators based on survey of the advanced technologies are provided, and also the neutral section configuration method which might be the best solution for newly electrified railways in Korea of 200km/H speed.

  • PDF

A Characteristic analysis of EHV insulators on long-term outdoor tests (송전용 애자의 장기실증시험 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.392-396
    • /
    • 2004
  • Experimental equipments for long-term outdoor tests of EHV insulators in outdoor were constructed. The testing insulators have been energized with 89 [kV] phase-to-ground AC voltage under identical condition at station, and the investigation was carried out for leakage current and various environments such as temperature, relative humidity and wind velocity. The test results of leakage current wave trends have forms on distorted waves including harmonics. The porcelain and glass insulators have low leakage current in case of daytime because moisture and humidity have relative low values. In comparison with these conditions, high leakage current was shown at dawn and rainy day due to high humidity. However, leakage current of polymer insulators was shown approximately $129[{\mu}m]$ without relation to the weather due to hydrophobicity on their surface.

  • PDF

The Evaluation of Flashover Characteristics of Polymer Insulators with Tracking Wheel Test (트래킹 휠 시험에 의해 열화된 폴리머애자의 섬락특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Yoon, Tae-Sang;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.82-85
    • /
    • 2000
  • Polymeric composite insulators are used for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate the tracking resistance of polymer insulators, we performed the tracking wheel test which is recommended by CEA LWIWG-01. And the flashover voltage tests were conducted for understanding electrical characteristics after tacking wheel test. Also, these insulators are studied by characterization methods such as contact angle measurement, SEM, etc.

  • PDF

A Characteristic Analysis of EHV Porcelain Insulators by Raw Materials (초고압 송전용 자기재 애자의 재질에 따른 특성 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il;Jung, Gil-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.146-149
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of the home production porcelain insulators by change of the alumina addition amount, 36000lbs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 wt.% alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained. Amount of alumina was contained most by 17 wt.% in case of insulators that were manufactured in 2001.

  • PDF