• Title/Summary/Keyword: Drain Noise

Search Result 96, Processing Time 0.024 seconds

A study on the noise criteria of water supply and drain installations in apartment bathroom (공동주택 욕실 급배수 설비소음 기준설정에 관한 연구)

  • Kim, Hang;Song, Guk-Gun;Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.484-487
    • /
    • 2007
  • This study was analyzed the correlation between physically measured values and psychological response for noise of water supply and drain installations in apartment bathroom. It exhibited the noise criteria of water supply and drain installations in apartment bathroom after recording noise of water supply and drain installations. Also, It was carried out the field psycho-acoustic test to find a correlation between physically measured values and psychological response of the noise criteria of water supply and drain installations in apartment bathroom, and the results is that 40dB (A) to 45dB (A) was investigated suitable in lowest criteria.

  • PDF

Gate-to-Drain Capacitance Dependent Model for Noise Performance Evaluation of InAlAs/InGaAs Double-gate HEMT

  • Bhattacharya, Monika;Jogi, Jyotika;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In the present work, the effect of the gate-to-drain capacitance ($C_{gd}$) on the noise performance of a symmetric tied-gate $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ double-gate HEMT is studied using an accurate charge control based approach. An analytical expression for the gate-to-drain capacitance is obtained. In terms of the intrinsic noise sources and the admittance parameters ($Y_{11}$ and $Y_{21}$ which are obtained incorporating the effect of $C_{gd}$), the various noise performance parameters including the Minimum noise figure and the Minimum Noise Temperature are evaluated. The inclusion of gate-to-drain capacitance is observed to cause significant reduction in the Minimum Noise figure and Minimum Noise Temperature especially at low values of drain voltage, thereby, predicting better noise performance for the device.

A Study on the Characteristics of Construction Noise by Sand Drain Method (Sand Drain 공법에 의한 작업시 발생하는 건설소음의 특성에 관한 연구)

  • Yun, Hae-Dong;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.500-505
    • /
    • 2000
  • Recently, with the increasing of construction works, large construction equipment are used to reduce the term of work and labor cost in construction field. Therefore, construction equipment noise has caused much annoyance for a number of dweller in nearby construction field and it has become a very serious problem in our living environment. Neverthless, in our country, adequite guidelines for the construction equipment noise are very deficiency because of the lack of basic data and insufficient research works. From this point of view, this study attempts to survey the characteristics of attenuation and propagation of Sand Drain Method in construction field. On the basis of measurement value, we analysed about prediction possibility of Sand Drain Method. This study also present a basic data found a effective plans for Sand Drain Method.

  • PDF

An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom (급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Choi, Eun-Suk;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

An Experimental Study on the Selection of the Proper Vocabularies for Evaluation about the Noise Emission from Water Supply and Drain Installations in Apartment Bathroom (공동주택 욕실 급배수 설비소음 평가를 위한 적정어휘 선정에 관한 실험적 연구)

  • Song, Guk-Gon;Kim, Hang;Lee, Tai-Kang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.679-682
    • /
    • 2007
  • This study aims to select the proper vocabularies for evaluation about the noise emission from water supply and drain installations in apartment bathroom. As a result of surveying overlapping vocabularies and scores of them for each sound sources, 'annoying', 'noisy', 'dynamic' and 'strident' are main unpleasant vocabularies to the noise from water supply and drain installations in apartment bathroom. And vocabularies such as 'dynamic', 'sudden', 'loudness', 'noisy' are classified into the first factor by analysis.

  • PDF

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom (공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Hang;Song, Guk-Gon;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

An study on the Noise rating of water supply and drain installations in apartment bathroom (급배수 설비소음 평가방법 선정을 위한 실험적 연구)

  • Lee, Tai-Kang;Ko, Kwang-Pil;Choi, Eun-Seok;Kim, Hang;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. The measurement procedure of water installations noise in apartment bathroom were established, so it is necessary to provide the evaluating method and criteria to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. After measuring the noise emission from the installations in many apartment bathroom, The noise were evaluated dB(A), N, NC index, To induce the appropriate method, the coefficient of the correlation among the evaluated numbers were analyzed. As a result, the dB(A) method is most easy to evaluating and very high correlated with N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

Analytical Thermal Noise Model of Deep-submicron MOSFETs

  • Shin, Hyung-Cheol;Kim, Se-Young;Jeon, Jong-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.3
    • /
    • pp.206-209
    • /
    • 2006
  • This paper presents an analytical noise model for the drain thermal noise, the induced gate noise, and their correlation coefficient in deep-submicron MOSFETs, which is valid in both linear region and saturation region. The impedance field method was used to calculate the external drain thermal noise current. The effect of channel length modulation was included in the analytical equation. The noise behavior of MOSFETs with decreasing channel length was successfully predicted from our model.

Field Measurements on Drain Noise in Bathroom of Apartment House (공동주택 욕실 배수소음의 현장 측정방법)

  • Yang, K.C.;Lee, T.G.;Kim, S.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.345-348
    • /
    • 2005
  • The method of measurement for field tests on noise emission from water closet in bathroom of apartment house. This part of standard gives detailed descriptions for field tests on noise emission from water closet in bathroom. The measuring position have to investigated measuring for emission noise.

  • PDF