• Title/Summary/Keyword: Device Simulator

Search Result 551, Processing Time 0.028 seconds

eFlowC: A Packet Processing Language for Network Management (eFlowC : 네트워크 관리를 위한 패킷 처리 언어)

  • Ko, Bang-Won;Yoo, Jae-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.1
    • /
    • pp.65-76
    • /
    • 2014
  • In this paper, we propose a high-level programming language for packet processing called eFlowC and it supporting programming development environment. Based on the C language which is already familiar and easy to use to program developers, eFlowC maintains the similar syntax and semantics of C. Some features that are unnecessary for the packet processing has been removed from C, eFlowC is highly focused on performing packet data, database, string byte information checking and event processing. Design high-level programming languages and apply an existing language or compiler technology, language function and compilation process that is required for packet processing will be described. In order to use the DPIC device such as X11, we designed a virtual machine eFVM that takes into account the scalability and portability. We have evaluated the utility of the proposed language by experimenting a variety of real application programs with our programming environment such as compiler, simulator and debugger for eFVM. As there is little research that devoted to define the formats, meanings and functions of the packet processing language, this research is significant and expected to be a basis for the packet processing language.

Fabrication and Characterization of Low Noise Amplifier using MCM-C Technology (MCM-C 기술을 이용한 저잡음 증폭기의 제작 및 특성평가)

  • Cho, H.M.;Lim, W.;Lee, J.Y.;Kang, N.K.;Park, J.C.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.11a
    • /
    • pp.61-64
    • /
    • 2000
  • We fabricated and characterized Low Noise Amplifier (LNA) using MCM-C (Multi-Chip-Module-Cofired) technology for 2.14 GHz IMT-2000 mobile terminal application. First, We designed LNA circuits and simulated it's high frequency characteristics using circuits simulator. For the simulation, we adopted high frequency libraries of all the devices used in LNA samples. By the simulation, Gain was 17 dB and Noise Figure was 1.4 dB. We used multilayer process of LTCC (Low Temperature Co-fired Ceramics) substrate and conductor, resistor pattern for the MCM-C LNA fabrication. We made 2 buried inductors, 2 buried capacitors and 3 buried resistors. The number of the total layers was 6. On the top layer, we patterned microstrip line and pads for the SMT device. We measured the high frequency characteristics, and the results were 14.7 dB Gain and 1.5 dB Noise Figure.

  • PDF

Optimization of the DC and RF characteristics in AlGaN/GaN HEMT (AlGaN/GaN HEMT 의 DC 및 RF 특성 최적화)

  • Son, Sung-Hun;Kim, Tae-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.1-5
    • /
    • 2011
  • In this paper, we investigated the characteristics of AlGaN/GaN HEMTs to optimize their DC and RF characteristics by using a two-dimensional device simulator. First, we analyzed the variation of the DC characteristics with respect to the variation of 2DEG concentrations when varying the Al mole fraction and the thickness of the AlGaN layer. Then, we examined the variation of the RF characteristics by varying the size and the location of the gate, source and drain electrodes. When the Al mole fraction increased from 0.2 to 0.45, both the transconductance and I-V characteristics increased. On the other hand, the I-V characteristics were improved but transconductance was decreased as the thickness of the AlGaN layer increased from 10nm to 50nm. In the RF characteristics, the gate length was found to be the most influential parameter, and the RF characteristics were improved when the gate length was shorten.

Geometry and Property Database for Korean Spine Research (한국인 척추 연구를 위한 형상 / 물성 정보 구축)

  • Lee, Seung-Bock;Lee, Sang-Ho;Han, Seung-Ho;Kwak, Dai-Soon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.488-493
    • /
    • 2011
  • The Korean spine geometry and property data for researchers were made by KISTI and Catholic Institute for Applied Anatomy. We took whole spine CT, X-Ray, BMD scan for making high resolution cross-sectional spine images using more 20 donated cadavers(60 - 80 years). Then we constructed 3-dimensional volume model using serial CT images by Mimics software. The major morphometric parameters of vertebrae were measured. Mechanical motion and property data were obtained by the same cadavers using the DEXA for BMD and the spine simulator. The Korean spine geometry and property data could be used for research and development of medical device.

IPMP(Intellectual Property Management and Protection) Service Interfaces based on MPEG Multimedia (MPEG 멀티미디어 미들웨어에 기반한 보호관리 서비스 인터페이스)

  • Choo, Hyon-Gon;Bang, Gun;Nam, Je-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.3
    • /
    • pp.325-334
    • /
    • 2007
  • In order to increase the promotion of multimedia processing techniques in MPEG standard, MPEG Multimedia Middleware (M3W) which supports middleware interface for multimedia processing is set up. In this paper, multimedia protection and management service interfaces based on MPEG Multimedia Middleware (M3W) are introduced. The service interfaces are based on component models of M3W and support normative IPMP messages. The proposed interfaces are composed of Tool interfaces and Trust management interfaces: Tool interfaces provide the functionality supporting terminal and tool based on the governed decoder model and Trust management interfaces provide the supporting functionality such as license managing and authentication required in DRM devices. As an application of the proposed interfaces, a JAVA based player simulator is shown. The proposed interfaces can be easily implemented under various device and application environments as an ISO/IEC 23004-2 standard middleware platform.

  • PDF

A Development of VPP Platform for the Efficient Utilization of Distributed Renewable Energy Resources (분산 재생에너지의 효율적 활용을 위한 가상발전소(VPP) 플랫폼 개발에 관한 연구)

  • Cho, Young-Hyeok;Baek, Seung-Yup;Choi, Won-Yong;Jeong, Dae-Yul
    • The Journal of Information Systems
    • /
    • v.27 no.2
    • /
    • pp.95-114
    • /
    • 2018
  • Purpose The recent concern over environmental problems such as greenhouse gas emission and fine dust contributes increasing interest in renewable energies. However the intrinsic characteristics of renewable energies, intermittent and stochastic generation, might cause serious problems to the stability and controllability of power grid. Therefore countermeasures such as virtual power plant (VPP) must be prepared in advance of the spread of uncontrollable distributed renewable energy resources to be one of major energy sources. Design/methodology/approach This study deals with the design concept of the VPP platform. we proposed as a technology solution for achieving the stability of power grid by guaranteeing a single power profile combining multiple distributed power sources with ICT. The core characteristics of VPP should be able to participate in the grid operation by responding to operation instructions from the system operator, KPX, as well as the wholesale electricity market. Findings Therefore this study includes energy storage device(ESS) as a controllable component as well as renewable energy resources such as photovoltaic and wind power generation. Based on this configuration, we discussed core element technologies of VPP and protype design of VPP solution platform according to system requirements. In the proposed solution platform, UX design for the integrated control center and brokerage system were included as well as ancillary service function to respond to KPX's operation instruction with utilizing the capability of ESS. In addition, a simulator was suggested to verify the VPP operations.

Properties of Dinickel-Silicides Counter Electrodes with Rapid Thermal Annealing

  • Kim, Kwangbae;Noh, Yunyoung;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.27 no.2
    • /
    • pp.94-99
    • /
    • 2017
  • Dinickel-silicide $(Ni_2Si)/glass$ was employed as a counter electrode for a dye-sensitized solar cell (DSSC) device. $Ni_2Si$ was formed by rapid thermal annealing (RTA) at $700^{\circ}C$ for 15 seconds of a 50 nm-Ni/50 nm-Si/glass structure. For comparison, $Ni_2Si$ on quartz was also prepared through conventional electric furnace annealing (CEA) at $800^{\circ}C$ for 30 minutes. XRD, XPS, and EDS line scanning of TEM were used to confirm the formation of $Ni_2Si$. TEM and CV were employed to confirm the microstructure and catalytic activity. Photovoltaic properties were examined using a solar simulator and potentiostat. XRD, XPS, and EDS line scanning results showed that both CEA and RTA successfully led to tne formation of nano $thick-Ni_2Si$ phase. The catalytic activity of $CEA-Ni_2Si$ and $RTA-Ni_2Si$ with respect to Pt were 68 % and 56 %. Energy conversion efficiencies (ECEs) of DSSCs with $CEA-Ni_2Si$ and $RTA-Ni_2Si$catalysts were 3.66 % and 3.16 %, respectively. Our results imply that nano-thick $Ni_2Si$ may be used to replace Pt as a reduction catalytic layer for a DSSCs. Moreover, we show that nano-thick $Ni_2Si$ can be made available on a low-cost glass substrate via the RTA process.

Characteristic Study of the Pulse Position on CHON, KWAN and CHUCK Using the Ultrasonic Waves (초음파 분석을 이용한 촌관척 위치별 혈관의 특성연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Ryu, Hyun-Hee;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 2007
  • The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women(22.28${\pm}$2.62 age) considered normal in terms of Body Mass Index(BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.

  • PDF

Optimization of Screw Pumping System (SPS) for Mass Production of Entrapped Bifidus

  • Ryu, Ji-Sung;Lee, Yoon-Jong;Choi, Soo-Im;Lee, Jae-Won;Heo, Tae-Ryeon
    • Food Science and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.566-571
    • /
    • 2005
  • Process of screw-pumping system (SPS) was optimized for mass production of encapsulated bifidus. SPS entrapment device was composed of feeding component, with optimized nozzle size and length of 18G (0.91 cm) and 4 mm, respectively, screw pump, and 37-multi-nozzle. Screw component had five wing turns [radius (r)=26 to 15 mm] from top to bottom of axis at 78-degree angle from middle of the screw, and two wings were positioned at screw edge to push materials toward nozzle. For nozzle component, 37 nozzles were attached to 20-mm round plate. Air compressor was attached to SPS to increase productivity of encapsulated bifidus. This system could be operated with highly viscous (more than 300 cp) materials, and productivity was higher than $1128\;{\pm}\;30\;beads/min$. Viability of encapsulated bifidus was $5.45\;{\times}\;10^8\;cfu$/bead, which is superior to that of encapsulated bifidus produced by other methods ($2.51{\times}10^8\;cfu$/bead). Average diameter of produced beads was $2.048\;{\pm}\;0.003\;mm$. Survival rate of SPS-produced encapsulated bifidus was 90% for Simulator of the Human Intestinal Microbial Ecosystem test and 88% in fermented milk (for 14 days). These results show SPS is effective for use in development of economical system for mass production of viable encapsulated bifidus.

A Study on Hand-signal Recognition System in 3-dimensional Space (3차원 공간상의 수신호 인식 시스템에 대한 연구)

  • 장효영;김대진;김정배;변증남
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.3
    • /
    • pp.103-114
    • /
    • 2004
  • This paper deals with a system that is capable of recognizing hand-signals in 3-dimensional space. The system uses 2 color cameras as input devices. Vision-based gesture recognition system is known to be user-friendly because of its contact-free characteristic. But as with other applications using a camera as an input device, there are difficulties under complex background and varying illumination. In order to detect hand region robustly from a input image under various conditions without any special gloves or markers, the paper uses previous position information and adaptive hand color model. The paper defines a hand-signal as a combination of two basic elements such as 'hand pose' and 'hand trajectory'. As an extensive classification method for hand pose, the paper proposes 2-stage classification method by using 'small group concept'. Also, the paper suggests a complementary feature selection method from images from two color cameras. We verified our method with a hand-signal application to our driving simulator.