• 제목/요약/키워드: DC offsets

검색결과 14건 처리시간 0.027초

지수 감쇄하는 DC 옵셋 영향을 제거한 푸리에 변환 기반 페이져 연산 기법 기법 (Fourier Transform-Based Phasor Estimation Method Eliminating the Effect of the Exponentially Decaying DC offsets)

  • 이동규;김철훈;강상희
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1485-1490
    • /
    • 2008
  • This paper proposes a new Fourier transform-based phasor estimation method to eliminate the adverse influence of the exponentially decaying dc offsets when Discrete Fourier Transform (DFT) is used to calculate the phasor of the fundamental frequency component in a relaying signal. By subtracting the result of odd-sample-set DFT from the result of even-sample-set DFT, the information of dc offsets can be obtained. Two dc offsets in a relaying signal are treated as one dc offset which is piecewise approximated in one cycle data window. The effect of the dc offsets can be eliminated by the approximated dc offset. The performance of the proposed algorithm is evaluated by using computer-simulated signals and EMTP-generated signals. The algorithm is also tested on a hardware board with TMS320C32 microprocessor. The evaluation results indicate that the proposed algorithm has the stable and accurate eliminating performance even if the input signal contains two decaying dc components having different time constants.

Direct-Conversion 수신기에서 DC offset 제거에 따른 성능 개선에 관한 연구 (A Study on a Performance Progress of Direct-Conversion Receiver as removing DC offset.)

  • 김철성;박성진;조형래
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.162-165
    • /
    • 2000
  • 본 논문에서는 AWGN 환경하에서 Direct-conversion 수신기 시스템에서 발생하는 DC offset을 제거하여 성능을 개선할 수 있는 방안으로 UC offset이 발생한 신호를 loop를 통해 누적, 평균화 하여 시변 DC offset 발생에 대처할 수 있는 방안을 모색하였다.

  • PDF

DC 옵셋의 영향을 제거한 페이저 연산 기법 (Phasor Estimation Method Eliminating the Effect of the DC offsets)

  • 이동규;김형규;권영진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.203_204
    • /
    • 2009
  • In this paper, we propose a Fourier transform-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Discrete Fourier Transform (DFT) is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. In this paper, the error due to DC offsets in a DFT is calculated and eliminated using the outputs of quaternity DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated by using computer-simulated signals and EMTP-generated signals. A performance evaluation showed that the proposed algorithm was not affected by system and fault conditions. Thus, the proposed algorithm can effectively suppress the adverse influence of DC offsets in a relaying signal.

  • PDF

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.

DFT 기반의 개선된 페이저 연산 기법을 적용한 거리계전 알고리즘 (Distance Relaying Algorithm Using a DFT-based Modified Phasor Estimation Method)

  • 이동규;강상희
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1360-1365
    • /
    • 2010
  • In this paper, we propose a distance relaying algorithm using a Discrete Fourier Transform (DFT)-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Most distance relays are based on estimating phasors of the voltage and current signals. A DFT is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. For this reason, distance relays have a tendency to over-reach or under-reach in the presence of DC offset components in a fault current. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. The error due to DC offsets in a DFT is calculated and eliminated using the outputs of an even-sample-set DFT and an odd-sample-set DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated for a-phase to ground faults on a 345 kV, 50 km, simple overhead transmission line. The Electromagnetic Transient Program (EMTP) is used to generate fault signals. The evaluation results indicate that adopting the proposed algorithm in distance relays can effectively suppress the adverse influence of DC offsets.

Design of a High-performance High-pass Generalized Integrator Based Single-phase PLL

  • Kulkarni, Abhijit;John, Vinod
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1231-1243
    • /
    • 2017
  • Grid-interactive power converters are normally synchronized with the grid using phase-locked loops (PLLs). The performance of the PLLs is affected by the non-ideal conditions in the sensed grid voltage such as harmonics, frequency deviations and the dc offsets in single-phase systems. In this paper, a single-phase PLL is presented to mitigate the effects of these non-idealities. This PLL is based on the popular second order generalized integrator (SOGI) structure. The SOGI structure is modified to eliminate the effects of input dc offsets. The resulting SOGI structure has a high-pass filtering property. Hence, this PLL is termed as a high-pass generalized integrator based PLL (HGI-PLL). It has fixed parameters which reduces the implementation complexity and aids in the implementation in low-end digital controllers. The HGI-PLL is shown to have the lowest resource utilization among the SOGI based PLLs with dc cancelling capability. Systematic design methods are evolved leading to a design that limits the unit vector THD to within 1% for given non-ideal input conditions in terms of frequency deviation and harmonic distortion. The proposed designs achieve the fastest transient response. The performance of this PLL has been verified experimentally. The results agree with the theoretical prediction.

멀티레벨 홀로그래픽 저장장치를 위한 적응 EM 알고리즘 (Adaptive Threshold Detection Using Expectation-Maximization Algorithm for Multi-Level Holographic Data Storage)

  • 김진영;이재진
    • 한국통신학회논문지
    • /
    • 제37A권10호
    • /
    • pp.809-814
    • /
    • 2012
  • 본 논문은 멀티레벨을 가지는 홀로그래픽 저장 장치에서 EM (Expectation-maximization) 알고리즘을 이용한 적응 문턱전압검출기를 제안한다. 멀티레벨을 이용한 홀로그래픽 저장 장치의 경우 DC 오프셋의 정도에 따라 비적응 문턱전압검출기의 성능에 매우 심각한 영향을 미친다. EM 방법은 채널을 통과한 데이터를 이용해 Expectation step과 maximization step을 반복하면서 평균과 분산을 추정하는 방법이다. DC 오프셋이 있는 상황에서 제안된 방법을 적용하여 문턱값을 찾아내서 검출한 결과 일정한 한도 내의 DC 오프셋의 경우는 DC 오프셋이 없는 경우와 동일한 성능을 보였다.

디지털 록인앰프를 이용한 비정현 계통하에서 강인한 PLL 방법 (A Robust PLL Technique Based on the Digital Lock-in Amplifier under the Non-Sinusoidal Grid Conditions)

  • 아쉬라프 모하마드 노만;칸 아마드 레이안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.104-106
    • /
    • 2018
  • The harmonics and the DC offset in the grid can cause serious synchronization problems for grid connected inverters (GCIs) which leads not able to satisfy the IEEE 519 and p1547 standards in terms of phase and frequency variations. In order to guarantee the smooth and reliable synchronization of GCIs with the grid, Phase Locked Loop (PLL) is the crucial element. Typically, the performance of the PLL is assessed to limit the grid disturbances e.g. grid harmonics, DC Offset and voltage sag etc. To ensure the quality of GCI, the PLL should be precise in estimating the grid amplitude, frequency and phase. Therefore, in this paper a novel Robust PLL technique called Digital Lock-in Amplifier (DLA) PLL is proposed. The proposed PLL estimate the frequency variations and phase errors accurately even in the highly distorted grid voltage conditions like grid voltage harmonics, DC offsets and grid voltage sag. To verify the performance of proposed method, it is compared with other six conventional used PLLs (CCF PLL, SOGI PLL, SOGI LPF PLL, APF PLL, dqDSC PLL, MAF PLL). The comparison is done by simulations on MATLAB Simulink. Finally, the experimental results are verified with Single Phase GCI Prototype.

  • PDF

직접변환 수신기 구조에서 In-Band Full-Duplex 시스템 설계와 성능 특성 평가 (Design and Performance Evaluation of In-Band Full-Duplex System Based on Direct Conversion Receiver)

  • 금홍식;안창영;유흥균
    • 한국전자파학회논문지
    • /
    • 제25권12호
    • /
    • pp.1258-1268
    • /
    • 2014
  • 본 논문에서는 DCR 구조의 IBFD 시스템을 설계하고 제안하는 시스템에서 자기 간섭 신호에 의한 DC offset 영향이 신호에 미치는 영향과 그에 따른 전체적인 시스템의 성능 특성을 분석한다. 시뮬레이션의 결과로 자기 간섭 신호가 RF cancellation에의해 완전히 제거되지 않고 다양한 크기로 DCR 구조의 수신 시스템에 인가되었을 경우, 상대국에서 보낸 수신 신호를 왜곡할 뿐만 아니라, 자기 간섭 신호 자체의 선형 특성을 왜곡시키는 것을 확인할 수 있다. 또한, 이러한 자기 간섭 신호에 의한 DC offset은 m-QAM의 변조에서 보다 다양한 레벨로 나타나기 때문에 m-QAM으로 변조된 자기 간섭 신호의 경우, 전체적인 심볼의 성좌도 형상을 크게 왜곡시키는 것을 확인할 수 있다. 이와 대조적으로 모든 심볼의 크기가 동일한 m-PSK로 변조된 자기 간섭 신호에 의한 DC offset은 단일 레벨로 나타나기 때문에, 전체적인 심볼의 성좌도 형상은 잘 유지되어 선형성이 잘 유지되는 것을 확인하였다. 즉, DCR 구조의 IBFD 시스템에서 m-PSK 변조가 m-QAM 변조에 비하여 보다 효과적인 것을 확인할 수 있다.

호모다인 간섭계를 이용한 레이저 진동 측정기의 개발 (Laser Doppler Vibrometer using the Bulk Homodyne Interferometer)

  • 라종필;경용수;왕세명;김경석;박기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.397-402
    • /
    • 2003
  • The FM demodulation method for a bulk homodyne laser interferometer is presented. The Doppler frequency that represents the surface velocity of a vibrating object is obtained by using the bulk homodyne laser interferometer, and converted to the voltage signal by using the proposed analogue FM demodulation circuit. The DC offsets of the interferent signals that are obtained from the bulk homodyne interferometer are eliminated by using a simple subtraction. The new method for compensation of the asymmetry of each channels is presented. The light power variation of the interferometer is normalized by using the Auto Gain Controller(AGC). The proposed FM demodulation algorithm is proved by the theoretical method, and validated by the experimental results. In experiments, the proposed FM demodulation algorithm is compared with the conventional demodulation methods.

  • PDF