DOI QR코드

DOI QR Code

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee (Department of Electrical Eng., Kyungpook National University) ;
  • Choi, Jong-Woo (Department of Electrical Eng., Kyungpook National University)
  • Received : 2013.05.21
  • Accepted : 2013.12.24
  • Published : 2014.03.20

Abstract

For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.

Keywords

References

  1. J. M. Carrasco, L. G. Franquelo, J. T. Bialasiewicz, E. Galvan, R. C. P. Guisado, Mz. A. M. Prats, J. I. Leon, and N. Moreno-Alfonso, "Power-Electronic systems for the grid integration of renewable energy sources: A survey," IEEE Trans. Ind. Electron., Vol. 53, No. 4, pp. 1002-1016, Aug. 2006. https://doi.org/10.1109/TIE.2006.878356
  2. B. D. Min, J. P. Lee, J. H. Kim, T. J. Kim, D. W. Yoo, K. R. Ryu, J. J. Kim, and E. H. Song, "A novel grid-connected PV PCS with new high efficiency converter," Journal of Power Electronics, Vol. 8, No. 4, pp. 309-316, Oct. 2008.
  3. J. K. Jeong, B. M. Han, J. Y. Lee, and N. S. Choi, "High-efficiency grid-tied power conditioning system for fuel cell power generation," Journal of Power Electronics, Vol. 11, No. 4, pp. 551-560, Jul. 2011. https://doi.org/10.6113/JPE.2011.11.4.551
  4. K. Kirubakaran, S. Jain, and R. K. Nema, "DSP-controlled power electronic interface for fuel-cell-based distributed generation," IEEE Trans. Power Electron., Vol. 26, No. 12, pp. 3853-3864, Dec. 2011. https://doi.org/10.1109/TPEL.2011.2138162
  5. B. Singh, K. Al-Haddad, and A. Chandra, "A review of active filters for power quality improvement," IEEE Trans. Ind. Electron., Vol. 46, No. 5, pp. 960-971, Oct. 1999.
  6. Mohamed Adel, Sherif Zaid, and Osama Mahgoub, "Improved active power filter performance based on an indirect current control technique," Journal of Power Electronics, Vol. 11, No. 6, pp. 931-937, Nov. 2011. https://doi.org/10.6113/JPE.2011.11.6.931
  7. K. H. Kwan, P. L. So, and Y. C. Chu, "An output regulation-based unified power quality conditioner with Kalman filters," IEEE Trans. Ind. Electron., Vol. 59, No. 11, pp. 4248-4262, Nov. 2012. https://doi.org/10.1109/TIE.2012.2193852
  8. IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems, IEEE Standard 1547-2003.
  9. D. G. Infield, P. Onions, A. D. Simmons, and G. A. Smith, "Power quality from multiple grid-connected single-phase inverters," IEEE Trans. Power Del., Vol. 19, No. 4, pp. 1983-1989, Oct. 2004. https://doi.org/10.1109/TPWRD.2004.829950
  10. L. Gertmar, P. Karlsson, and O. Samuelsson, "On DC injection to AC grids from distributed generation," in Proc. Eur. Conf. Power Electron. Appl., p. 10, 2005.
  11. M. P. Kazmierkowski and L. Malesani, "Current control techniques for three-phase voltage-source PWM converters: a survey," IEEE Trans. Ind. Electron., Vol. 45, No. 5, pp. 691-703, Oct. 1998.
  12. R. Y. Kim, S. Y. Choi, and I. Y. Suh, "Instantaneous control of average power for grid tie inverter using single phase D-Q rotating frame with all pass filter," in Proc. IEEE 30th Annu. IEEE IECON, Vol. 1, pp. 274-279, 2004.
  13. D. N. Zmood, D. G. Holmes, and G. H. Bode, "Frequency-domain analysis of three-phase linear current regulators," IEEE Trans. Ind. Appl., Vol. 37, No. 2, pp. 601-610, Mar./Apr. 2001. https://doi.org/10.1109/28.913727
  14. D. N. Zmood and D. G. Holmes, "Stationary frame current regulation of PWM inverters with zero steady-state error," IEEE Trans. Power Electron., Vol. 18, No. 3, pp. 814-822, May 2003. https://doi.org/10.1109/TPEL.2003.810852
  15. R. Teodorescu, F. Blaabjerg, M. Liserre, and P. C. Loh, "Proportional-resonant controllers and filters for grid-connected voltage-source converters," IEE Proc.-Electr. Power Appl., Vol. 153, No. 5, pp. 750-762, Sep. 2006. https://doi.org/10.1049/ip-epa:20060008
  16. S. Jiang, D. Cao, Y. Li, and F. Z. Peng, "Grid-connected boost-half-bridge photovoltaic microinverter system using repetitive current control and maximum power point tracking," IEEE Trans. Power Electron., Vol. 27, No. 11, pp. 4711-4722, Nov. 2012. https://doi.org/10.1109/TPEL.2012.2183389
  17. L. Hang, S. Liu, G. Yan, B. Qu, and Z. Lu, "An improved deadbeat scheme with fuzzy controller for the grid-side three-phase PWM boost rectifier," IEEE Trans. Power Electron., Vol. 26, No. 4, pp. 1184-1191, Apr. 2011. https://doi.org/10.1109/TPEL.2010.2089645
  18. J. A. Suul, K. Ljokelsoy, T. Midtsund, and T. Undeland, "Synchronous reference frame hysteresis current control for grid converter applications," IEEE Trans. Ind. Appl., Vol. 47, No. 5, pp. 2183-2194, Sep./Oct. 2011. https://doi.org/10.1109/TIA.2011.2161738
  19. A. K. S. Bhat and S. B. Dewan, "A novel utility interfaced high-frequency link photovoltaic power conditioning system," IEEE Trans. Ind. Electron., Vol. 35, No. 1, pp. 153-159, Feb. 1988. https://doi.org/10.1109/41.3079
  20. W. M. Blewitt, D. J. Atkinson, J. Kelly, and R. A. Lakin, "Approach to low-cost prevention of DC injection in transformerless grid connected inverters," IET Power Electron., Vol. 3, No. 1, pp. 111-119, Jan. 2010. https://doi.org/10.1049/iet-pel.2008.0319
  21. L. Bowtell and A. Ahfock, "Direct current offset controller for transformerless single-phase photovoltaic grid-connected inverters," IET Renew. Power Gen., Vol. 4, No. 5, pp. 428-437, Sep. 2010. https://doi.org/10.1049/iet-rpg.2009.0043
  22. G. Buticchi, E. Lorenzani, and G. Franceschini, "A DC offset current compensation strategy in transformerless grid-connected power converters," IEEE Trans. Power Del., Vol. 26, No. 4, pp. 2743-2751, Oct. 2011.

Cited by

  1. High-Precision Active Suppression of DC Bias in AC Grids by Grid-Connected Power Converters vol.64, pp.1, 2017, https://doi.org/10.1109/TIE.2016.2542126
  2. A Novel Active Damping Control of a Three-phase PWM Inverter with LC Filter vol.10, pp.4, 2015, https://doi.org/10.5370/JEET.2015.10.4.1589
  3. Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor vol.15, pp.6, 2015, https://doi.org/10.6113/JPE.2015.15.6.1593
  4. A Study on Current Ripple Reduction Due to Offset Error and Dead-time Effect of Single-phase Grid-connected Inverters Based on PR Controller vol.20, pp.3, 2015, https://doi.org/10.6113/TKPE.2015.20.3.201
  5. DC Offset Error Compensation Algorithm for PR Current Control of a Single-Phase Grid-Tied Inverter vol.11, pp.9, 2018, https://doi.org/10.3390/en11092308