• Title/Summary/Keyword: Common mode 전압

Search Result 84, Processing Time 0.026 seconds

An 8b 200MHz Time-Interleaved Subranging ADC With a New Reference Voltage Switching Scheme (새로운 기준 전압 인가 방법을 사용하는 8b 200MHz 시간 공유 서브레인징 ADC)

  • Moon, Jung-Woong;Yang, Hee-Suk;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.4
    • /
    • pp.25-35
    • /
    • 2002
  • This work describes an 8b 200MHz time-interleaved subranging analog-to-digital converter (ADC) based on a single-poly digital CMOS process. Two fine ADCs for lower digital bits of the proposed ADC employ a time-sharing double-channel architecture to increase system speed and a new reference voltage switching scheme to reduce settling time of the reference voltages and chip area. The proposed intermeshed resistor string, which generates reference voltages for fine ADCs, improves linearity and settling time of the reference voltages simultaneously. The proposed sample- and-hold amplifier(SHA) is based on a highly linear common-drain amplifier and passive differential circuits to minimize power consumption and chip area with 8b accuracy and employs input dynamic common mode feedback circuits for high dynamic performance at a 200MHz sampling rate. A new encoding circuit in a coarse ADC simplifies the signal processing between the coarse ADC and two successive fine ADCs.

Design and Analysis of Phase-Shift Full-Bridge LDC using Common Mode Coupled Inductor (커먼모드 커플드 인덕터를 적용한 위상천이 풀브리지 컨버터 LDC 설계 및 분석)

  • Choi, Jin-Yong;Heo, Gyeong-Hyeon;Lee, Woo-Seok;Choi, Seung-Won;Lee, IL-Oun;Lee, Jun-Young;Lee, Seung-Jun;Oh, Kwang-Ho;Lee, Sang-Hyeok
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.20-22
    • /
    • 2019
  • 본 논문에서 공통모드 커플드 인덕터(Common Mode Coupled Inducter, CMCI)를 적용한 2단 직렬 위상천이 풀브리지 컨버터를 제안한다. 제안하는 위상천이 풀브리지 컨버터는 고주파수로 동작하며, 높은 입력전압에 대응할 수 있다. 풀브리지를 직렬로 쌓은 구조로 상단 풀브리지 컨버터와 하단 풀브리지 컨버터가 동시에 스위칭 한다. 2차측은 센터텝 정류기를 사용하여 풀브리지 정류기에 비해 다이오드 전압강하가 절반이라는 장점을 가진다. 또한, 변압기에 CMCI를 적용하여 1차측 상단과 하단의 전류 균형을 유지하도록 구성하였다. 제안하는 위상천이 풀브리지 컨버터의 5.8kW급 시제품을 제작하여 그 타당성을 검증하였다.

  • PDF

Meduim Vector PWM for Elimination of Common Mode Voltage Variation in Three-level Inverter (3-레벨 인버터의 공통모드 전압 변동 제거를 위한 Medium Vector PWM)

  • Choi, Nam-Sup;Lee, Eun-Chul;Ahn, Kang-Soon
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.205-206
    • /
    • 2014
  • 본 논문에서는 3-레벨 인버터 시스템에서 공통 모드 전압 변동 제거를 위한 새로운 Medium Vector PWM(MVPWM)을 제안한다. 제안된 MVPWM의 특징은 다음과 같다. 1) 스위칭 상태와 관계없이 공통모드 전압은 일정하게 유지된다. 2) 무게 중심좌표계 방법에 의하여 구현되므로 구현이 간단하고 직관적이다. 본 논문에서는 시뮬레이션을 통하여 제안된 MVPWM의 위와 같은 특성을 밝히고 태양광 인버터의 제어에 적합함을 입증하였다.

  • PDF

Carrier Comparison PWM Method of Vienna Rectifier for Reduction of Common Mode Voltage (비엔나 정류기의 공통모드 전압 저감이 가능한 캐리어 비교 PWM 기법)

  • Lee, Dong-Hyun;Choi, Won-Il;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.126-133
    • /
    • 2016
  • This paper proposes a new PWM method to reduce the common mode voltage change in three-level Vienna rectifier. This new proposed PWM method uses medium voltage vector for the three-level Vienna rectifier to determine the sum of three-phase voltage zero, and the common mode voltage variation is decreased. Using the carrier comparison method, the switching function generator for three-level Vienna rectifier has been proposed. The effects of the proposed PWM method have been verified through simulation using the PSIM.

Performance Comparison of Common-Mode Voltage Reduction PWM Methods in Terms of Modulation Index (변조지수에 따른 공통모드 전압 저감 PWM 기법 성능 비교)

  • Heo, Geon;Park, Yongsoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2021
  • This study introduces a new pulse width modulation (PWM) method to reduce common-mode voltages (CMVs) and then compares its performance with other reduced CMV-PWM (RCMV-PWM) methods. CMVs should be reduced to ensure the electromagnetic compatibility and safety of grid-connected inverters. RCMV-PWM methods attempt to synthesize voltage references without zero vectors, which cause high CMV peaks. In these methods, the peak-to-peak magnitude of CMVs can be reduced by one-third of the conventional space-vector PWM. The introduced method splits every reference vector into two vectors to avoid the use of zero vectors. The performances of the RCMV-PWM methods are analyzed in accordance with the modulation index through simulation and experiment.

Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection (중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제)

  • Bae, Young-Sang;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.31-40
    • /
    • 2014
  • This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter.

H8 Inverter System for Driving PMSM applying Model Predictive Contorol Method for Common-Mode Voltage Reduction (공통모드전압 저감을 위한 모델예측제어기법을 적용한 PMSM 구동용 H8 인버터 시스템)

  • Choo, Kyung-Min;Kim, Jun-Chan;Jung, Won-Sang;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.185-186
    • /
    • 2018
  • 모델 예측전류제어 과정에서 공통모드전압을 저감 하기 위한 기존연구방안들이 제시되어 왔지만 두 상의 스위치 함수가 변동하는 데드 타임 구간이나 영 전압벡터 두 가지를 모두 저감시키지는 못하였다. 본 논문에서 제안한 모델예측전류제어는 영 전압벡터와 데드 타임에서의 공통모드전압을 고려하여 H8 인버터시스템에서 공통모드전압을 저감하였을 뿐만 아니라 영 전압 벡터 사용으로 인한 THD도 개선하였다. 모델예측전류제어를 적용한 H8 인버터 시스템의 공통모드전압의 저감과 출력전류 THD 개선을 시뮬레이션을 통해 증명하였다.

  • PDF

Circulating current control using the DC-link voltage deviation for the parallel connected three-level NPC converters (병렬형 3상 3레벨 NPC 컨버터의 DC단 불평형을 이용한 순환전류 저감)

  • Park, Jung-Hoon;Jung, Jun-Hyung;Son, Yeong-Deuk;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.168-169
    • /
    • 2017
  • 본 논문에서는 ZCMV(zero common mode voltage) PWM을 사용하는 병렬형 3상 3레벨 NPC 컨버터의 DC단 전압의 불평형 제어를 이용한 순환전류 저감 알고리즘을 제안한다. 이상적으로 ZCMV PWM은 공통 모드 전압을 발생하지 않지만, 초기 운전 및 데드타임과 같은 실제적인 문제로 인해 공통 모드 전압이 발생한다. 발생한 공통 모드 전압은 미세한 순환전류를 발생시키며 이는 컨버터의 효율을 감소시킨다. 따라서, 본 논문에서는 DC단 전압 불평형 제어를 이용하여 순환전류를 저감하는 제어 알고리즘을 제안한다. 상, 하단 DC 전압의 불평형은 공통 모드 전압을 발생시키며 이를 통해 미세하게 발생한 순환전류를 저감하여 컨버터의 효율을 향상 시킬 수 있다. 제안한 알고리즘은 시뮬레이션을 통해 타당함을 검증하였다.

  • PDF

A New PWM Strategy for reducing Common Mode Voltage in PWM boost Converter/lnverter Fed ac Motor Drives. (PWM 승압형 컨버터/인버터를 시스템에서 커먼 모드 전압 저감을 위한 새로운 PWM 기법)

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2484-2486
    • /
    • 1999
  • 본 논문에서는 PWM 승압형 컨버터/인버터를 사용한 교류전동기 구동시스템에서 커먼 모드 전압의 크기를 dc 버스 전압 1/3이하로 제한시키는 새로운 공간전압벡터 PWM 기법을 제안한다. Dc 버스 전압의 2/3에 해당하는 커먼 모드 전압 펄스가 발생하는 경우에 대하여 고찰하고 각각의 경우에 대한 인버터 스위칭 시점의 이동을 통한 제거 방법을 제안한다. 제안된 방법은 부가의 하드웨어를 요구하지 않고 소프트웨어적으로 손쉽게 구현될 수 있으며, 전력변환기의 제어성능에 영향을 미치지 않는다는 장점을 가진다.

  • PDF

A Study on the Induced Voltages on Subscriber Telecommunication Lines from High-Speed Electrified Railway Line (고속전철에 의한 통신선로 전력유도 현상에 관한 고찰)

  • Oh, Ho-Seok;Kang, Seong-Yong;Yun, Ju-Yeong;Kim, Hak-Chul;Choi, Kyung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.71-79
    • /
    • 2008
  • This paper analyzed the voltage induction phenomena on the telecommunication lines by electromagnetic coupling from high-speed A.C. electrified railway. The induced common mode voltages and the induced differential mode voltage on the telecommunication line was measured by notified standard method in the regulation of Korea. The test lines consist of 2 separated lines of 20 m and 300 m in influence distance each for comparison, with 2km inducing length. The analysis is made on the induced voltages from the different influence distances and the different earthing points, and also on the waveform and spectrum distributions. It is proved that the induction is arisen so good and the measured values are fair enough against noise such as the earth voltage differencing, and the current measuring scheme is also rightful.