Abstract
This paper analyzed the voltage induction phenomena on the telecommunication lines by electromagnetic coupling from high-speed A.C. electrified railway. The induced common mode voltages and the induced differential mode voltage on the telecommunication line was measured by notified standard method in the regulation of Korea. The test lines consist of 2 separated lines of 20 m and 300 m in influence distance each for comparison, with 2km inducing length. The analysis is made on the induced voltages from the different influence distances and the different earthing points, and also on the waveform and spectrum distributions. It is proved that the induction is arisen so good and the measured values are fair enough against noise such as the earth voltage differencing, and the current measuring scheme is also rightful.
본 논문은 고속 전기철도 시설로 인해 가입자 통신선로에서 발생하는 전력유도에 대한 현상과 관련 규정 및 유도전압 측정 결과를 분석한 것이다. 전력유도 현상의 명확한 이해를 돕기 위하여 이론적 배경을 제시하였고, 국내 법규에서 이상시유도위험전압, 상시유도위험종전압, 기기오동작유도종전압, 잡음전압 등으로 구분되는 유도전압 중에서 공통모드 전압에 해당하는 상시유도위험종전압과 잡음평형도 평가에 필요한 선대지잡음전압 및 차동모드전압인 선간잡음전압을 우리나라 고시 측정방법에 따라 측정하였다. 측정을 위해 이격거리가 각각 약 20 m와 300 m인 2 km 길이의 통신선로를 설치하여 실험하였으며 측정된 유도전압의 변화 및 파형 특성 등을 비교, 분석함으로써 고속전철에 의한 통신선로 전력유도 현상을 고찰하고 현행 측정방법의 타당성을 검토하였다.